HomeMy WebLinkAbout14- City Administrator CITY OF SAN BERN.RDINO - REQUEST FAR COUNCIL ACTION From: SHAUNA CLARK Subject: Authorization of Loan from Sewer Line Construction Fund (245) - Dept: CITY ADMINISTRATOR Retrofitting Lighting Fixtures in City Hall Date: 4-22-93 Synopsis of Previous Council action: 06-01-92 - Report on retrofitting lighting fixtures in City Hall accepted and filed; Director of Public Works/City Engineer directed to prepare plans, and City Administrator instructed to develop resolution to borrow $148 , 000 from the Sewer Line Construction Fund. Recommended motion: Adopt resolution. cc: Jim Penman Roger Hardgrave Signature Contact person: Fred Wilson Phone: 5122 Supporting data attached: Staff Report, Resolution Ward: 1 FUNDING REQUIREMENTS: Amount: $187 , 000 Source: (Acct. No.) 001-092-56366 (Acct. Description) Lighting Retrofit - City Hall Finance:e , _ � ' (�►�._ Council Notes: '7a_ngnq Annnfin Item Aln 141 CITY OF SAN BERN RDINO - REQUEST F R COUNCIL ACTION STAFF REPORT On June 6, 1992 , the Council authorized the Director of Public Works to develop plans and specifications to retrofit the lights in City Hall with more energy efficient light. The idea behind this retrofit project was to reduce the energy costs in this facility while maintaining adequate lighting levels. It was felt that this objective could be accomplished by replacing existing equipment with new energy efficient equipment, adding occupancy sensors, daylight overrides and other energy saving devices. A report was subsequently prepared by an outside energy consultant, Energy Controls and Concepts, dated 5-12-92 , at the request of the Facilities Management Division. The objective of this report was to investigate the lighting fixtures in City Hall and make recommendations on how they could be retrofitted to conserve energy. This report is attached. Major recommendations of this report include: RECOMMENDED MODIFICATIONS 1. Replace current 4 ft. fluorescent lamps with new T-8 fluorescent lamps. The new energy efficient lamps will provide the same foot candles for 20% less energy and life of the lamp will increase 20%. In several areas, such as storage, walkways, etc. lamps per fixture will be reduced from 4 to 2 lamps. 2 . Replace existing ballast with electronic ballasts. The electronic ballasts will reduce energy directly related to the ballast 30%. The largest savings will be related to the overall heat reduction that occurs when changing from standard ballast to electronic. The reduction in the heat will reduce the amount of cooling required and extend the life of the lamps. 3 . Replace existing incandescent/flood lamps with compact fluorescent lamps. The energy savings is 30% per fixture and the lamp life will increase 80%. 4 . The modifications also include adding occupancy sensors and daylight overrides in various locations. ANNUAL ENERGY SAVINGS Energy Savings From Light Modifications . . . . . . . $36, 100 Energy Savings From Reduction in Cooling. . . . . . 7 , 551 Total . . . . $43,651 75-0264 PAY BACK Including a $11, 000 rebate, upon completion of project, from Southern California Edison Company, the pay-back is 48 months. Below is an estimate of the total project cost: Construction Contract $148, 000 Consultant' s Design Fee 12 , 000 Contract Administration & Inspection 2 , 500 Sub-Total $162 , 500 Contingencies (15%)+/- 24 , 500 TOTAL ESTIMATED PROJECT COST $187,000 The proposed resolution authorizes a loan from the Sewer Line Construction Fund (245) in the amount of $187, 000. This loan will be repaid in five (5) annual payments, beginning on 1-1-94 , plus simple interest at a rate of 4%. There is a sufficient balance in the Sewer Line Construction Fund to finance this loan, without deferring any budgeted sewer projects. We recommend that the loan be approved, in order to provide the necessary financing for this energy conservation project. 1 RESOLUTION NO. 2 RESOLUTION OF THE CITY OF SAN BERNARDINO AUTHORIZING A LOAN FROM THE SEWER LINE CONSTRUCTION FUND (245) TO ACCOUNT NO. 3 001-092-53666 - CITY HALL LIGHTING PROJECT, IN THE AMOUNT OF $187 , 000 TO FRONT THE COST TO BE INCURRED IN CONNECTION WITH THE 4 UPGRADE OF CITY HALL LIGHTING. 5 BE IT RESOLVED BY THE MAYOR AND COMMON COUNCIL OF THE CITY OF SAN BERNARDINO AS FOLLOWS: 6 SECTION 1 . The Director of Finance is hereby directed to 7 make a loan in the amount of $187 , 000 from the Sewer Line 8 Construction Fund (245) to Account No. 001-092-53666 , Cite Hall 9 Lighting Project, to front the cost to be incurred in connection 10 with the upgrade of City Hall Lighting. 11 SECTION 2. The Sewer Line Construction Fund will be 12 repaid in five annual payments to be made each January 1 , 13 beginning January 1 , 1994 , at a simple interest rate of 4% from 14 Account No. 001-322-53402 - Electric Charges - City Hall. 15 16 17 18 19 20 21 22 23 24 25 26 27 28 5-12-93 1\L,LVV• lLV il1V 1\1V�L.0 LVLLLV 11\Vla vulul\ L1L\u �rVl•V 11\V\/l y\I L\ a. v_ ..i rV CITY vALL LIGHTING PROJECT 1 I HEREBY CERTIFY that the foregoing resolution was duly 2 adopted by the Mayor and Common Council of the City of San 3 Bernardino at a meeting thereof, held on the 4 day of 1993 , by the following vote, to-wit: 5 Council Members : AYES NAYS ABSTAIN ABSENT 6 NEGRETE 7 CURLIN 8 HERNANDEZ 9 OBERHELMAN 10 (OFFICE VACANT) 11 POPE-LUDLAM 12 MILLER 13 14 Rachel Clark, City Clerk 15 The foregoing resolution is hereby approved this 16 day of 1993. 17 18 Tom Minor, Mayor 19 City of San Bernardino Approved as to form 20 and legal content: 21 James F. Penman City Attorney 22 23 By 24 25 26 27 28 - 2 - Energy Controls & Concepts 1758-B Orange Tree Lane • Redlands. CA 92374 • (714)335.1699 • FAx (714)335.5715 Prepared For: Mr. Bert Murphy May 12, 1992 Manager Facilities Management Department CC: Mr. Jim W. Sharp Project Manager Economic Development Agency Project: San Bernardino City Hall Building Address: 300 North "D" Street San Bernardino, CA 92418 Objectives: Update, modify and improve existing lighting equipment with new energy efficient replacements. Increase the lamp life and reduce electrical costs. Improve existing light levels as well as lamp life. Provide client a reasonable time frame for recapturing initial costs. Coordinate energy audits with the respective utility company in the area(s). Estimate utility rebates(if any) and cost savings. General Specifications: Includes energy efficient fluorescent lamps, electronic ballasts and controls in specified areas. Also includes compact fluorescent lamps in place of incandescents/floods and some replacement of diffusers. The following data was compiled using estimated burn times for all the various areas in this facility. You will note that burn times, lighting specifications and applications will vary in each area. In addition, please note that lamp wattage is computed based on lamp/ballast types in accordance with specifications provided by ANSI (the American National Standards Institute), the primary source by which electrical standards and measurements are assessed, and manufacturers' specifications. These assumptions are believed to be as close to accurate as can possibly be assessed based on our various sources of information that we deem reliable. Estimations in burn time were gathered from various sources at this facility. r Project Areas Description Area 1 6th Floor - Copy & Reception Area 2 6th Floor - Break Rooms Area 3 6th Floor - Administration, Conference & Storage Area 4 6th Floor - Sister City Showcase Area 5 6th Floor - City Attorney Area 6 6th Floor - City Attorney Area 7 6th Floor - Administration / Mayor/ Conference Area 8 6th Floor - Administration Halls Area 9 6th Floor - Mayor's Office Area 10 6th Floor - Mayor's Office Area 11 6th Floor - Conference Room / Mayor's Suite Area 12 5th Floor - Break Rooms Area 13 5th Floor- Water Department Aria 14 5th Floor - BP / Storage/ Copy/ Conference Area 15 5th Floor - Water Department Area 16 5th Floor - Water Department/ Circulation Area 17 5th Floor - Water Board Control Room Area 18 4th Floor- Occupational Health / Risk Management Area 19 4th Floor - Occupational Health/ Risk Management 20 4th Floor - OH Copy Room Ara: 21 4th Floor- Occupational Health / Risk Management Area ::2 4th Floor- Public Services Arez 23 4th Floor - Public Services/ Finance Area 24 4th Floor - Public Services/ Conference "A" & "B" / Break Room / Copy Area/ Filing Area 25 4th Floor - Finance / Break Room Area 26 4th Floor - Finance / Purchasing Area 27 4th Floor - Finance / Purchasing Area 28 4th Floor - Finance / Storage Area 29 3rd Floor - Planning / Public Works Area 30 3rd Fir pr - Planning / Public Works Area 31 3rd Finer - Smrags Rooms & Break Rooms Area 32 3rd Floor - Planning / Public Works Area 33 3rd Floor - Planning / Public Works-Storage Area 34 3rd Floor - Planning/ Circulation Area 35 2nd Floor - City Treasurer Area 36 2nd Floor - 0:ty Treasurer-Storage Area 37 2nd Floor - City Treasurer/ Storage/ Filing Rooms r Area 38 2nd Floor - City Clerk Area 39 2nd Floor - City Clerk-Storage Area 40 2nd Floor - Civil Service Area 41 2nd Floor - Civil Service-Storage Area 42 Mezzanine - Council Offices Area 43 Mezzanine - Council Offices Area 44 Mezzanine - Council Offices Area 45 Mezzanine - Conference Area 46 Mezzanine - Conference Area 47 1 st Floor - Lobby Area 48 1 st Floor - Council Chambers Area 49 1 st Floor - Council Chambers Area 50 1 st Floor - Council Chambers Area 51 1 st Floor - Council Chamber/ Audio Visual Area 52 1 st Floor - Council Chambers Area 53 1 st Floor - Council Chambers (Wall Washers) Area 54 Basement - EOC Area 55 Basement - B57/ Break Room / Mail Room Area 56 Basement - Central Services Area 57 Basement - Central Services/ Office Rooms Area 58 Basement - Central Services Area 59 Basement - MIS / Building Management Area 60 Basement - MIS / Building Management Area 61 Basement - MIS / Building Management Area 62 Penthouse - Mechanical Area 63 Penthouse - Mechanical Area 64 Stairwells Area 65 Common - Elevators Area 66 Common - Circulation Area 67 Common - Circulation Area 68 Common - Circulation Area 69 Common - Electrical Rooms Area 70 Common - Ditto Rooms/ Storage Area 71 Common - Restrooms Area 72 Common - Restrooms/ Janitorial Area 73 Common - Elevators Area 74 Common - Exit Signs Area 75 Opt. 1 Perimeter Luminaires / Ambient Light Sensing/ Continuous Dim Area 75 Opt. 2 Perimeter Luminaires/ IR Occupancy Sensing / Daylight Overri Area 1 i to Floor - Copy & Kecep:ion Specifications: 2* x 4' Drop-Ins/ 4 lamp/ F40CW/SS - 34 Watts Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures. Add One Passive I.R. Senor. Anticipated Will equal existing light levels. Lamp life will increase significantly. Results: Ballast heat will be greatly reduced. Color rendering will also improve. Fixture / Lamp Analysis Existing Promsed Fixture Quantity 2 2 Lamps Per Fixture 4 2 Urnp Type F40CW/SS FO32T8-41 ks Lamp Watts (Per fixture) 156 7n Lamp Cost $1.95 $2.50 Lamp Life (kilowatt hours) 15000 (20000) 26000 Kilowatt Hour Rate 0.105 0.105 i5 Months of Cooling 9 Annual Burn Time (hours) 2730 1911 Comparitive Cast List•t Energy 89.43 30.50 L.irr,ps 0.00 0.00 Labor 0.00 0.00 CI(X)M9 19.12 6.52 Total Annual: Cost 10E.55 37.02 Estimated Annual Cost Savings $71.53 0.66 Percent M Estimated Annual Kilowatt Usage (existing) 852 Estimated An:n ua! Kiiowatt Usage (after completion) 290 Estimated Reduction - Annual Kilowatt Hours 561 Page 11 OPTION 1 - CONTINUOUS .MMING &ALS 0 Estimated Cumulative Cost Savings 1 st Year 2nd Year 3rd Year Energy 37241.43 75227.69 113593.81 Lamps 2055.52 4234.37 6478.59 —' -bor 5299.55 10917.07 16703.12 Cooling 7795.21 15746.32 23776.95 52391.71 106125.46 160552.47 4th Year 5th Year Energy 152343.59 191480.87 Lamps 8790.13 11171.02 Labor 22662.75 28801.17 Cooling 31887.88 40079.92 215684.36 .271532:99 ... . .. . . .. ... . ... ..................... .... . . .. ASSUMPTIONS & NOTES The above forecast as well as other data contained herein is based on the following assumptions; ti) Wattage is calculated on a "per fixture basis" in accordance with the equipment manufacturers' specifications and/or ANSI standards. d (2) Kilowatt hour rates are calculated using a standing average. This average is subject to variances depending on "KW Demand" and demand cycles in the service area of the respective utility. (3) The various "project areas" reflect only estimated lighting energy costs/savings and associated cooling costs savings. Cooling costs savings and incremental heating cost increases associated with light energy reductions are calculated using an ASHRAE net space conditioning savings formula. (Light Energy Savings/Monthly Correction Factor'.35) (4) The "summary" pages reflect lighting energy, cooling energy related to lighting, lamp and ibor cost variances. This includes inflation factors of one percent (1.0%) annually for the purpose of calculating energy costs. Inflation factors for lamps and labor are calculated at three percent (3.0%) annually. (5) Labor is calculated at 20 minutes per lamp installation (average) multiplied by a$10.00 hourly rate. (6) Cooling is not factored in the analysis for outside areas. -OPTION 1 - CONTINUOUS .,AMING & ALS ASSUMPTIONS & NOTES (con't.) (7) For the purpose of estimating energy rebates, applicable programs from the respective utility company(s) are utilized. In some cases the utility may or may not calculate cooling load reductions for the purpose of estimating rebates. The respective energy services representative from the utility company will veriiy and substantiate the information contained herein. Estimated Annual Kilowatt Usage (existing) 616585 Estimated Annual Kilowatt Usage (after completion) 261905 42% Projected Estimated Annual Kilowatt Hours Saved 354680 58% Kilowatt Hours Reduced (Controls) 43587 Estimated Monthly KW Demand Reductions 103.79 Total Project Cost $147,855.72 Estimated Utility Rebate (KW Reduced) $10,379.00 Other Controls $1,307.61 Total Less Estimated Rebate $136,169.11 First Year Estimated Return On Investment (ROI) 38:596; Estimated Recapture Period (months) 31.2 NOTE: This evaluation does not take into account additional cost savings attributed to depreciation. The total project costs are binding, however, any added variance in actual materials and/or labor may affect these costs. Total savings estimates include labor, materials and energy. Sales tax will be added to the invoice at the current applicable rate. All labor and materials are guaranteed as specified. All work will be completed in a timely and professional manner and in accordance with acceptable practices. Any alterations, changes or modifications in the above specifications will be approved only in writing and added to the above estimate. Customer agrees to pay a charge equal to one and one-half percent (1.5%) per month on all past due balances of any invoices in order to reimburse Energy Controls & Concepts for its estimated administrative costs and other losses which may be associated with such delinquint accounts. Notwithstanding, nothing contained herein shall be construed as an alternative performance provision except as provided for in writing. All balances are otherwise due within ten (10) working days from the date of completion of all work specified. There will be an additional charge (based on a "per drum" basis at current disposal rates) for proper and legal disposal of magnetic ballasts containing PCB's. There will be an additional charge (based on $.10 per lineal foot) for proper and legal disposal and/or recycling of fluorescent lamps. OPTION 1 - CONTINUOUS D{ ING & ALS Green Lights 1 Environmental Impact The Environmental Protection Agency EPA has taken a strop look at the positive 9 Y ( ) 9 environmental impact of "demand side management". In particular, the EPA estimates that for each kilowatt hour of energy saved there is an associated reduction in generation side pollution. The EPA has recently undertaken the task of retrofitting their own facilities in Washington D.C. with newer triphosphors lamps, specular reflectors and electronic ballasts. This newer technology has proven to result in tremendous savings with an even greater enhancement to the quality of fight in all environments. One very significant effect of an energy efficient lighting retrofit is that of emmission reductions. Outlined below is an estimate of your annual reduction of carbon dioxides, sulfur dioxides and nitrogin oxides emitted from the generation of electric power based on national statistics. Estimated Annual Carbon Dioxide Reductions Obs.) 567488 Estimated Annual Sulfur Dioxide Reductions Obs.) 4150 Estimated Annual Nitrogen Oxide Reductions (lbs.) 2188 For more information on the environmental affects of demand side management, please contact us or the EPA or talk to us regarding the "Green Lights Partner Program". OPTION 2 - IR OCCUPANCY SL jORS & DAYLIGHT OVERRIDE ' Estimated Cumulative Cost Savings 1 st Year 2nd Year 3rd Year { Energy 36100.91 72923.84 110115.00 i Lamps 2127.55 4382.75 6705.61 Labor 5394.63 11112.94 17002.79 Cooling 7551.42 15253.87 23033.34 51174.51 103673.40 156856.74 i 4th Year 5th Year Energy 147678.06 185616.76 f Lamps 9098.16 11562.48 1 Labor 23069.35 29317.90 Cooling 30890.61 38826.45 .......... ..... ....... ...... 210736.18 1265323.59 ............... ................................. ASSUMPTIONS & NOTES The above forecast as well as other data contained herein is based on the following assumptions; (1) Wattage is calculated on a "per fixture basis" in accordance with the equipment manufacturers' specifications and/or ANSI standards. (2) Kilowatt hour rates are calculated using a standing average. This average is subject to variances depending on "KW Demand" and demand cycles in the service area of the respective utility. (3) The various "project areas" reflect only estimated lighting energy costs/savings and 1 associated cooling costs savings. Cooling costs savings and incremental heating cost increases associated with light energy reductions are calculated using an ASHRAE net space conditioning savings formula. (Light Energy Savings/Monthly Correction Factor'.35) (4) The "summary" pages reflect lighting energy, cooling energy related to lighting, lamp and labor cost variances. This includes inflation factors of one percent (1.0%) annually for the purpose of calculating energy costs. Inflation factors for lamps and labor are calculated at three percent (3.0%) annually. (5) Labor is calculated at 20 minutes per lamp installation (average) multiplied by a$10.00 hourly rate. (6) Cooling is not factored in the analysis for outside areas. m I , OPTION 2 - IR OCCUPA. ,Y SENSORS & DAYLIGHT OVERRIDE ASSUMPTIONS & NOTES (con't.) (7) For the purpose of estimating energy rebates, applicable programs from the respective utility company(s) are utilized. In some cases the utility may or may not calculate cooling load reductions for the purpose of estimating rebates. The respective energy services representative from the utility company will verify and substantiate the information contained herein. Estimated Annual Kilowatt Usage (existing) 616585 Estimated Annual Kilowatt Usage (after completion) 272767 44% Projected Estimated Annual Kilowatt Hours Saved 343818 56% Kilowatt Hours Reduced (Controls) 40216 Estimated Monthly KW Demand Reductions 110.31 Total Project Cost $131,406.60 Estimated Utility Rebate (KW Reduced) $11,031.00 Other Controls $1,206.48 Total Less Estimated Rebate $119,169.12 ............................__ .. ............................. First Year Estimated Return On Investment (ROI) <42.9%'. .......:....... .. Estimated Recapture Period (months) 27.9 +A NOTE: This evaluation does not take into account additional cost savings attributed to .,, depreciation. The total project costs are binding, however, any added variance in actual materials and/or labor may affect these costs. Total savings estimates include labor, materials and energy. Sales tax will be added to the invoice at the current applicable rate. All labor and materials are guaranteed as specified. All work will be completed in a timely and professional manner and in accordance with acceptable practices. Any alterations, changes or modifications in the above specifications will be approved only in writing and added to the above estimate. Customer agrees to pay a charge equal to one and one-half percent (1.5%) per month on all past due balances of any invoices in order to reimburse Energy Controls & Concepts for its estimated administrative costs and other losses which may be associated with such delinquint accounts. Notwithstanding, nothing contained herein shall be construed as an alternative performance provision except as provided for in writing. All balances are otherwise due within ten (10) working days from the date of completion of all work specified. There will be an additional charge (based on a "per drum" basis at current disposal rates) for proper and legal disposal of magnetic ballasts containing PCB's. There will be an additional charge (based on S.10 per lineal foot) for proper and legal disposal and/or recycling of fluorescent lamps. 'OPTION 2 - IR OCCUPANC ENSORS & DAYLIGHT OVERRIDE Green Lights / Environmental Impact 1 The Environmental Protection Agency (EPA) has taken a strong look at the positive environmental impact of "demand side management". In particular, the EPA estimates that for each kilowatt hour of energy saved there is an associated reduction in generation side pollution. The EPA has recently undertaken the task of retrofitting their own facilities in Washington D.C. with newer triphosphors lamps, specular reflectors and electronic ballasts. This newer technology has proven to result in tremendous savings with an even greater enhancement to the quality of light in all environments. One very significant effect of an energy efficient lighting r'btrofit is that of emmission reductions. Outlined below is an estimate of your annual reduction of carbon dioxides, sulfur dioxides and nitrogin oxides emitted from the generation of electric power based on national statistics. Estimated Annual Carbon Dioxide Reductions Obs.) 550109 Estimated Annual Sulfur Dioxide Reductions Obs.) 4023 Estimated Annual Nitrogen Oxide Reductions (lbs.) 2121 »� For more information on the environmental affects of demand side management, please contact us or the EPA or talk to us regarding the "Green Lights Partner Program". 4