REPORT NO 30
CITY OF SAN BERNARDINO
DEPARTMENT OF BUILDING AND SAFETY
300 North D Street
SAN BERNARDINO, CA. 92418
:In HIBIT "A"
An inspection was made o he below mentioned structure(s )
and/or premises, and substandard conditions which shall
include but not be limited to the following, were observed.
The owner/s were sent a certified mailing of these condi-
tions.
The recommendation is for abatement of the structure(s)
and/or premises;
All such substandard buildings or premises are hereby de-
clared to be public nuisances and such nuisances shall be
abated by the repair, removal or demolition of such unsafe
buildings by the proper procedure. Permits are required
prior to starting repair or demolition work.
Total costs incurred to date: $ �n G
OWNER r ►���1. DATE PREPARED
ADDRESS 452.E TYPE BLDG/VIOLATIONt�,d„
CITY Inc . Cam. �Q&&O ADDRESS l�� fib• S+.
PHONE NO. ASSESSOR 'S NO. pp 05
DATE OF INSPECTION
VIOLATIONS
STRUCTURE—BUILDING
Open/vacant building[UFC11. 41/11. 4123 Secure all
\y buildings to FHA standards to prevent unauthorized
entrance. Secure doors and windows with fitted plywood
painted to match house trim. Openable windows must be
provided with quick release mechanisms where security
screens are installed on bedroom windows (UBC 1204i ).
2. Fir* damaged structurels3 specifically
ESBMC 19. 16. 2403 Secure the necessary permits and repair
Within thirtyE303 days to building codes or demolish.
3. Inadequate fire protection or fire—fighting
equipmentEUHC 9. 901, 10. 1001n, UFC 10. 3013 Provide as
i
required by codes proper firs—extinguishing systems or
- 'i?quipment. a
4. Inadequate eziisCUP4C9. 801. 10. 100im, UBC33. 3303, UFC
art. ill Additional exits may be required to be in
compliance -with building codes.
f _
3. Inadequate Foundation—sagging floors in
CUHC10. 1001 c, d. j, k, 1, USC1. 10443foundation or piers must
b• provided.
b. Inadequate walls/vertical supports in
which have been weakened by deterioration or overloading
a CUHC10. 1001c, d. h, 1. 1, 1 must be replaced or strengthened.
7_ Inadequate ceiling height in
CUHC3. 303.. UBC12. 12071 All habitable and service roams
shall have 7f t. bin. ceilings.
A. Inadequate roost dimensions in
CUHC3. 503. - UBC12. 12073
9. Inadequate ventilation/light in
CVHC3. 304, UBC12. 12053 All habitable rooms shalt have an
aggregate window area of not less than 1/10th the floor
area or 10 sq. ft. whichever is greater and an openable
window area of 1/2 the total area requirement. Bathrooms
must have a minimum of 3 sq. ft. or be provided with
mechanical ventilation.
10. Improper use of unitCUHC10. 1001*3 The us* of
as must be discontinued.
iZ. Broken doors or wind awsCUFC1i. 41i/11. 412 UBC1. 104d3 See
Number ane for correction.
iZ. Inadequate ratproof ing CUHC10. 1001 k1 A11 foundation and
attic vents or openings must be covered with 1/4 inch
mesh screening.
13.. Illegal addition/substandard ' secsssarq buildings
CU13CCL 301a UHM 3013 Addition of
most conform to codes or be demolished.
14. Broken/missing ezterior siding/stucco on
CU4C10. 1001b, c, d. h. 1• UBC17. 17071 must be repaired or
replaced.
13 Inadequate doorCUBC33. 3304. UFC12. 12. 1043 Install new
door at or repair existing door to insure
it closes properly or if a lack is present that it locks
properly-
2
I
-. 470
1.#. Chimney structure u19sound CUBC1. 1044, 2. 203.
UHC10. 1001c, d, h, i, j, k, I. I Remove chimney to roof line,
cap at this point and seal iPirebox or repair structur
ally to code.
HEALT4-SAN?TAT T CN
17. Pool has stagnant Water inadequate fence
inadequate gat: CS3MC13. 48, States code Title17CAC
Swimming pool ac. 24. 100. H&S Cade77743 Drain, repair,
or replace according to codes.
18. Debris/junk/inadequate garbage starageCHealth and
Sanitation Regulations Title 3 chap. 2 33. 023, M. 024,
S13MC8. 21. 030. 8. 21. 040, 8. 21. 030, 8. 21. 090, 8. 24. 020,
8. 24. 030 S. 24. 040. S. 24. 0303 Remove debris/junk and
provide suitable containers with lids for rubbish and
garbage.
19. -Unlicensed/inoperative vehicle Year !Sake
Lic* CSBMC8. 33. 010k3 .. Remove or stars in a
building.
20. Insects-vorminr-srimal droppingsCSSMC6. 04. 120, 6. 08.080,
UW-10. 10O1b.-d, k, 13 Adequate measures must bo taken to
eliminate this condition in
21. Unsanitarq drainboardCUHC6. 601. 10. 1001c, d, j, 1,
UBC=. 2316k3 Reseal or replace-drainbcard backsplash.
22. Unsanitarq floarcov*ring-flooring in
is a health hazardCUBC1_ 1044, UHC10- 1001d, j, I3. Recover
or reseal properly.
2Z Dwolling lacks hot•, waterCUHC3. 303, 10. IOOia, d, kI Hot
water of not less than 120 degrees F. must be provided
to required plumbing fixtures.
24. hater beater illegally installed in: bathroom_
bedroom_,LLTX=- 202- S_ 304-303, to C7. 701c, UBCZ 2033
Relocate water beater to a suitable location under
- r
25. hater beater improperly ventedCU?,M= 2OZ 5. 304v S. -CO.
USM 203, UHC7. 7O1c3 Vents shall extend 12 inches above
the point of *sit from the roof. All vent pipes to be
secured.
26. Roof leaking in the area above
CUBC1. 1044. 2. 203. UHC6. 601. 10. 1001b, c, d, h, i, j, k, 13
Repair root.
ELECTR ZCAI_ .
27. Overf using CUSCZ_ t04d. UHC2. 202, 4. 401, 7. 701 b, 9. 901,
10. 1001b, d, e. i, j. k. 1. NEC2. 202art. 90. 63 Fused electrical
3
nn
R
branch circuits shall b• provided W i th non-tamparab le
fuses not to exceed 23y amps for lights/20 amps to
receptacles. 1-
28. Missing electricial covers/fixtures in y,f �. �- a Rv�SL.
r CUBC:. 1044. UHC2. 202n. 7. 701 b. 9. 901.
10. IOOib, d, to is is k, I. NEC2. 202.art. 90. 61 All outlets and
siritches must have proper covers and all elec`ricial
fixtures must be properlq installed and secured to the
building.
29. Inadequate, outlets in - '
NECsoc. 2103 Each habitable roe• must have 2 convsenc:
outlets or 1 outlet and 1 light fixture. Bathrooms must
have 1 light fixture and GFI plug.
30. Electrical service is inadequate for existing loads
'• ` - sorved CNECsoc2303 A new service designed to supplq a
Minimum of 60 ampere 3 wire service for up to 3 Cf ive3. .
taco wire branch circuits capacitq.
31. Hazardous/illegal miring in
CUBC1. 1044. 2- 203o UHC2. 202. 4. 401, 7. 701b, 9. 901-
10. 1001b, d, e. 1, J. k, 1. NECZ 202art90. 63 Must be replaced,
properlq repaired or removed to eliminate hazards.
MECMANICA-L-HEATING
3Z Illegal gas heaterCs3 and/or gas appliances in
CUMC2. 202, 3. 304&509. UHC7. 701c. UBM 2033 All unvented
or open flame gas appliances must be disconnected and
rssoved from premises and the gas pipes capped in a
manner that prevents reconnection of those appliances.
33. Inadequate heatCUHC7.'701a3 An approved heating sgst*m
shall be installed capable of providing 70 degrees F
three feet above floor fn all habitabl• .rooss. s
34. Inadoquato/missing gas shutaff__safotV valve__
connection.at _ _ _CURC1_ 1044. 2. 203.
i1MC1104d. 3s 302a&1=Cc-23. UPC12- 1:.:=3ml An approved shut
of#/valvs/ con"estion shall be installod in an
` `tea. arjacontJaccessible location for all gas fired
appliances_
3�. Combustibles are stared too near heating appliances in
CUMCB. 80"Z. 7. 703 7043
Remove combustibles. Check manufacturers specifications.
PLt,�JMB ZNC
36. Leaking/broken/plugged sorer drains in
CUBC1. 104d, 2. 202, ' 4. 401, 3- 503s 10. 1001b. d. 1. k, 1. All
fixtures and appliances must be properlq connected to
serer lines and maintained in a sanitarq condition.
4
j <
37. Leakl ng-broked pipes-missing plumbing fixtures iri
CUSC1. 104d. 2. 202, 4. 401, 5. 305. 10. 1001d. 1. k, I, 3 All
crater pipes and fixtur*s must be free of leaks and
• maintained in a serviceable and sanitary condition.
38. Inca era tiv*-missing pressur* temperature relief vale*
for hot water systemCUBC1. 104d, 2. 203. UHC2. 202, 4. 401,
10. 1001d, f, I, UPC-A.0. 1007, 13. 1303-13061Rep lace valve.
39. Cross connectad. plumbing fixtureCs3 in
CUPC1. 102*&110. 6. 608, 10. 1003h3 Water inlets must be a
minimum of 1 inch above the rim of the v*9901 serviced.
Inlets in water closet Ctailet3 tanks must be *quipped
with approved ANTI-SIPHON devices With 1 inch clearance
above the overt I ow tube.
39A. Yard sprinklers must be free of cross connections with
approved vacuum br*ak*rCs3 installed at least six C&I
inches above surrounding ground, and heads- serviced.
40.
NOT TO BE OCCUPIED CUBC2. 203. 3. 307, 3. 301-3033 Dwelling
shall not be occupied until violations noted above have
been corrected and approved by a Building Inspector from
the City of San Bernardino Building and Safety
Department.
41_ A Certificate of Occupancy will be required to reoccupy
prop arty CUBC2- 203. 3. 307, 3- 301-50:33-
42. Iaproper occupancyCUHC10. 1001o, UBC2. 203, 3.307. 3. 301-
3032 Occupancy is not . allowed in this building or
portion thereof, you must vacate the area.
43. NutsanceCUHC1. 1044, UHC4.4612
This is an attractive hazard which say prove to be,
dstarimsntal to humans. It must b• provided protection,
repaired, cleaned up, or removed immediately.
Firs hazard in or on naL
t 2!'
- =C1_ 1044. Z 203. UMCZ 202. 4.1401. S. 801. 9. 901.
10. 1001c. d. J• k, I. UFCZ 201, 3. 1013 Remove, the building,
device,apparatus, equipment, combustible waste or
- vegetation which can cause or augment the spread and
intensity of fir* or explosion_
43. Faulty materials of construction in
CUBC1. 1044. 2 203, UHC10_ 1001c. d. 3, k. 1. I All materials
of constuction must be allowed or appoved by the Uniform
Building Coda. and -adequately maintained in good and
safe condition.
3
InadOt uat* maint*nance of Z2�ec� e�
CUBCs. 104d, 2. 203, UHCZ OZT_ 4.4oi
UMC1. 1044, 2. 20Z
UPC:d, 2. NEC2. 202. 90. 1, 90. 4. 90. 6. NFC2. 202. 3. 1013
Repaid' and/or replace building or portion th*r*o!.
47. Smok* d*t*c tortsl r*quir*dCUHC12. 1210a. UFC APPEND. 1—
AM6I Install snake d*tsctors as required.
Addrs 's required on all buildings and/or aptsCUFC10. 209.
SBMC1 3Z 0301. Applq address information on building.
49. rll*qAl. F Construction which requires permits and
insp*iti on's CUSCI 301-3031.
• 3Q SUPP �.��..... „
This insp*ttion report was given to:
A prop*rtq owner,
11 manag*r.
C tenant,
b bq hard d*livorg&
x_ t regular mail.
-•.XXX F certified mail. 9/15/87, 10/19/87
an March ,
Inspector Sig atvra
b
�v -
RECEIVE.
1 D Orn 40,
1�« l a I v r K , C � lr c&(,o '87 NOV 20 A 8 :36
NOV 201987 U
p S - 30/7 13UILDING SAFETY
CITY OF SAM B cRNAR0IM0
�lA`J/ a C✓ �, d C"(7
T
fL"Y b/ /r
771-e /71 ,v �� e� /
� l / /� a c�l///f�
Q Y
C I S !Q v 6 1
r.: T !Oi►
' C?fj,I 0
CWi�C Fyny
Me;
� �
! �� �� y" 5
QY2� covnc /* Sari n<< dlsZV
7Z)
Lj �C
y
Cr
ood cv�l
Curs �,, ro �'v �/ /S
o rQ �✓ -L� rT�
0
e."
YLO h Yo Xi ivgl �p
3, o00 "� �a � S ooa `-`� ��
A, s 0/
all / e- C
0/ y
�vCA .
5 1,4 C /y
er