Loading...
HomeMy WebLinkAbout11-Development Service ORIGINAL CITY OF SAN BERNARDINO - REOUEST FOR COUNCIL ACTION From: Valerie C. Ross, Director Subjeet: Authorize the Director of Development Services to execute Contract Change Order No. Two with Weka, Inc. for Sewer Force Main and Colton Lift Station improvements at Inland Center Drive - Sewer Main & Sewer Encasements at Mill Street (SW08-08) 1-215 Freeway widening (Segment 3) and authorization to amend the FY 08/09 Budget. Dept: Development Services Date: April 29, 2009 File Nos. 3.7742.2 MCC Date: May 18,2009 Synopsis of Previous Council Action: 02-19-08 The Mayor and Common Council adopted a Resolution awarding a contract to Weka, Inc. for Sewer and Street Improvements (SW08-08). 09-05-08 Contract Change Order No. One was approved in the amount of $161,884.67 with Weka, Inc. for the Sewer Force Main and Colton Lift Station improvements at Inland Center Drive - Sewer Main & Sewer Encasements at Mill Street (SW08-08) 1-215 Freeway Widening (Segment 3). Recommended Motion: 1. Authorize the Director of Finance to amend the FY 08/09 budget by increasing the revenue of Fund No. 242 (Street Construction) by $170,000 and allocate this additional amount to Account No. 242-362-5504-7747 "SW08-08 Segment 3 Sewer Relocation along 1-215 Freeway", and 2. Authorize the Director of Development Services to execute Contract Change Order No. Two with Weka, Inc. for the Sewer Force Main and Colton Lift Station improvements at Inland Center Drive - Sewer Main & Sewer Encasements at Mill Street (SW08-08) 1-215 Freeway widening (Segment 3). ~u.~ Valerie C. Ross Contaet Person: Robert Eisenbeisz, City Engineer Phone: Ext. 5203 Supporting data attached: Staff Report & CCO No. Two Ward: 3 FUNDING REQUIREMENTS: Amount: $ 300.000.00 Source: (Acet. Nos.) 242-362-5504-7747 Acet. Description: Caltrans Reimbursement Finance: Agenda Item No.-1L- 5'..I8-D't CITY OF SAN BERNARDINO - REQUEST FOR COUNCIL ACTION STAFF REPORT Subject: Authorize the Director of Development Services to execute Contract Change Order No. Two with Weka, Inc. for Sewer Force Main and Colton Lift Station improvements at Inland Center Drive - sewer main & sewer encasements at Mill Street (SW08-08) 1-215 Freeway widening (Segment 3) and authorization to amend the FY 08/09 budget. Background: In June of2005, the California Department of Transportation (Caltrans) proposed that the City of San Bernardino enter into a Utility Agreement as part of the realignment and widening of the 1- 215 Freeway. The agreement, which required Caltrans to reimburse the City for all engineering, inspection and construction costs associated with the relocation of our facilities, was signed by the Mayor on June 29, 2005. The project consists of the following three phases: Phase I 1. Relocate four sewer siphons. Phase 2 I. Relocate an existing sewer force main outside the newly acquired freeway rights of way. 2. Improve the existing sewer lift station to accommodate additional flows. 3. Install a new sewer main in Mill Street. 4. Encase both the new and existing sewer mains in Mill Street. Phase 3 1. Relocate the existing sewer force main east of Ring Road and south ofInland Center Drive. On February 19, 2008, the Mayor and Common Council approved a Resolution to award a contract to Weka, Inc. for construction of Sewer Force Main and Colton Lift Station Improvements at Inland Center Drive and Sewer Main and Sewer Encasements at Mill Street (SW08-08), per Project Plan No. 12350. Under the utility agreement, Caltrans will reimburse the City for all cost associated with the relocation of conflicting utilities regarding the 1-215 widening project up to $4,171,365.00, which reflects the estimated cost of construction with contingencies based upon the approved plans and specifications. In addition to this contract there were two other contracts awarded for sewer relocation work. All contracts relate to this project are below the estimated cost of construction. Change Order: During construction of the sewer force main the contractor encountered unforeseen conditions and utilities as follows: 2 - CITY OF SAN BERNARDINO - REQUEST FOR COUNCIL ACTION STAFF REPORT I. When the contractor went to install three new pumps for the sewer force main it was determined that the Caltrans approved plans and specifications did not provide for the micro- processor required to operate the pumps. The contractor utilized the pump manufacture to design, construct and install the micro-processor and control panel. The additional work was completed at a cost of$35,095.57. 2. During construction it was determined that the generator enclosure was too small to accommodate the new generator; therefore the generator was relocated to a new location. The relocation required the contractor to cone drill the concrete wall of the electrical room to install the conduits. The additional work was completed at a cost of$I,056.48. 3. The newly installed backup generator for the sewer pump station was installed with earthquake shock absorbing springs. The generator was self contained; however the underside of the generator was exposed to the elements. The contractor was directed to provide and install metal skirts along the bottom of the generator to eliminate the exposure to the elements. The additional work was completed at a cost of $2,427.06. 4. During construction the contractor encountered two electrical conduits that were not shown on Caltrans approved plans; the first was an existing conduit, which was to be abandoned and the second was a temporary conduit. The contractor was required to stand by until Caltrans determined that the sewer force main could fit between the (2) conduits. The stand by time resulted in an additional charge of$2,947.85. 5. When Caltrans poured the bridge over Inland Center Drive, he did not account for the fact that the bridge has a vertical curve and the sewer force main line is straight. In order to accommodate the sewer supports the contractor was required to grind the concrete bridge. The additional work was completed at a cost of$5,259.64. 6. At the time of the sewer force main installation, Caltrans had not placed fill on Inland Center Drive to final grade. Additionally, after the sewer force main was installed in the newly constructed bridge at Inland Center Drive, it was determined that the westerly end of the force main might be at risk to damage until Caltrans completed their earth fill in this area. The contractor was directed to protect the force main with a concrete slurry encasement for protection. The additional work was completed at a cost of$3,036.68. 7. At the time the new sewer force main was constructed, Caltrans had not completed the earth fill at the west end of the Inland Center Drive bridge; therefore, the contractor had to remobilize and install the air vac on the sewer force main. The air vac item was not listed on the Caltrans approved bid list. The additional work, including the price of the air vac, was completed at a cost of $4,474.56. 8. Caltrans was on a fast-track construction schedule for the northerly portion of the Inland Center Drive bridge. The new pumps for the sewer force main could not be installed prior to this portion of the bridge completion. At Caltrans direction, the contractor was required to 3 CITY OF SAN BERNARDINO - REQUEST FOR COUNCIL ACTION STAFF REPORT (Continued) provide and man the standby pumps to expedite the transfer of sewage to the newly constructed sewer force main. The additional work was completed at a cost of $39,802.48. 9. During construction it was discovered that two existing residents' sewers on Esperanza Street were connected to the sewer mainline that was in Caltrans right-of-way. This was not shown on the Caltrans approved plans. It was necessary to pothole and connect the house laterals to the utilities in "I" Street and the existing sewer laterals from each home to facilitate the design of the new lateral tie-in in "I" Street. The additional work resulted in a cost of $101,690.11. 10. During construction it was determined that the business at the east end of Henderson Lane was connected to a lateral that was in Caltrans right-of-way and was to be abandoned. This was not shown on the Caltrans approved plans. It was necessary to construct a mainline sewer in Henderson Lane and tie into the mainline sewer in "I" Street. This new mainline would service the business. The additional work was completed at a cost of$97,911.00. 11. After the new sewer force main was installed in Inland Center Drive, a contractor working for Caltrans was relocating another utility and damaged the new force main. The contractor was directed to repair the damaged force main at an additional cost of$5,299.07. Financial Impact: The revised estimated project costs are as follows: TOTAL Original Contract Amount $1,141,690.00 Contract Change Order No. One $161,884.67 Contract Change Order No. Two $299,000.50 Total Pro.iect Cost $1,602,575.17 This change order represents a net increase of 21 % of the original contract amount and the cumulative increase in 32.6%. Approximately $130,000 is currently available in the project account. Staff is recommending that $170,000 more is needed in Account No. 242-362-5504-7747 "SW08-08 Segment 3 Sewer Relocation along 1-215 Freeway" to provide a total funding amount of $300,000. This amount is adequate to fully fund Change Order No. two. Caltrans will reimburse the total cost of the project, including change orders, upon completion of the work. 4 CITY OF SAN BERNARDINO - REQUEST FOR COUNCIL ACTION STAFF REPORT (Continued) Recommendation: 1. Authorize the Director of Finance to amend the FY 08/09 budget by increasing the revenue of Fund No. 242 (Street Construction) by $170,000 and appropriate this additional amount to Account No. 242-362-5504-7747 "SW08-08 Segment 3 Sewer Relocation along 1-215 Freeway", and 2. Authorize the Director of Development Services to execute Contract Change Order No. Two with Weka, Inc. for the Sewer Force Main and Colton Lift Station improvements at Inland Center Drive - Sewer Main & Sewer Encasements at Mill Street (SW08-08) 1-215 Freeway widening (Segment 3). Attachments: Change Order No. Two 5 DEVELOPMENT SERVICFS DEPARTMENT ~ 300 North "0" Street. San Bernardino' CA 92418-0001 Planning & Building 909.384.5057 . Fax: 909.384.5080 Public WorkslEngineering 909.384.5111 . Fax: 909.384.5155 www.sbcity.org CONTRACT CHANGE ORDER NO. TWO FILE NO. 3.7742.2 W.O. NO. 7742 DATE: MAY 18, 2009 PROJECT: CONSTRUCTION OF SEWER FORCE MAIN & COLTON LIFT STATION IMPROVEMENTS AT INLAND CENTER DRIVE - SEWER MAIN & SEWER ENCASEMENTS AT MILL STREET (SW08-08) 1-215 FREEWAY WIDENING (SEGMENT 3) TO: WEKA, INC. 826 BROOKSIDE AVENUE, STE. G REDLANDS, CA 92373 GENTLEMEN: You are hereby compensated for performing the additional work as follows: ITEM NO: DESCRIPTION OF CHANGE COST 1-1 Design, Construct & Install Control Panel $ 35,095.57 1-2 Core Drill Electrical Room Relocate Generator $ 1,056.48 1-3 Skirt Generator $ 2,427.06 1-4 Conflict with Signal Conduit $ 2,947.85 1-5 Grind Bridge Deck for Sewer Supports $ 5,259.64 1-6 Slurry Back-Fill Protection for Sewer Forced Main & Slurry Protect $ 3,036.68 Force Main at Bridlle 1-7 2-inch Tap on Sewer Forced Main & Move-In to Place Air Vac $ 4,474.56 1-8 Bypass & Pump Sewer Lift Station $ 39,802.48 1-9 Pothole Existing Sewer Lateral & Install Sewer Laterals S.F.R. $ 101,690.11 1-10 Install Sewer Main & Lateral in Henderson Lane $ 97,911.00 1-11 Repair Sewer Force Main $ 5,299.07 TOTAL COST CCO #1 $ 299,000.50 CHANGE ORDER NO. TWO - WEKA. Inc. CONSTRUCTION OF SEWER FORCE MAIN &: COLTON LIFT STATION IMPROVEMENTS AT INLAND CENTER DRIVE _ SEWER MAIN &: SEWER ENCASEMENTS AT MILL STREET (SW08-08) 1-215 FREEWAY WIDENING (SEGMENT 3) JUSTIFICATION: DesillO. Construct & InstaIJ Control Panel Item The contractor was required to install (3) new pumps for the sewer force main. 1-1 However, the approved plans and specifications did not provide for the micro-processor No. to operate these pumps. The contractor utilized the pump manufacturer to design, construct and install the micro-processor and control panel. Core Drill Electrieal Room Reloeate Generator Originally, the backup generator was designed to be located in the existing generator 1-2 enclosure. The enclosure was too small to accommodate the new generator; therefore, the generator was relocated to a new location. This relocation required the contractor to cone drill the concrete wall of the electrical room to install conduits. Skirt Generator The newly installed backup generator for the sewer pump station was installed on a 1-3 concrete pad. Although the generator itself is self -contained, the underside of the generator was exposed to the elements. The contractor was directed to provide and install metal skirts along the bottom of the generator to elilninate exposure to the elements. Conflict witb SillOal Conduit When the contractor was installing the new force main, be encountered (2) electrical 1-4 conduits; (I) existing conduit, which is to be abandoned and (1) temporary conduit. The contractor was required to stand by until Caltrans determined we could slide between the (2) conduits with force main installation. Grind Bridlle Deek for Sewer Snnoorts When the Caltrans contractor poured the bridge over Inland Center Dr., he did not 1-5 account for the fact that the bridge has a vertical curve and the force main sewer line is straight. The contractor was required to grind the concrete of the bridge to accommodate the sewer supports. Slurrv Back-FiB Protection for Sewer Foreed At the time of installation of the force main, Caltrans had not placed fill on Inland Center Drive to final grade. This left the force main vulnerable to danJage. The contractor was required to place slurry concrete around the newly installed force main for protection 1-6 Slurrv Protect Foree Main at Bridlle After the susceptible sewer force main was installed in the newly constructed bridge at Inland Center Dr., it was determined that the westerly end of the force main could be susceptible to damage until Caltrans completed their earth fill in this area. The contractor was directed to protect the force main with a concrete slurry encasement for protection. 2-ineb Tan on Sewer Foreed Main The contractor was required to install a 2-inch tap on the sewer force main to allow for the installation at an air vac. 1-' Move-In to Plaee Air Vac At time of construction of the new force main, Caltrans had not been completed the earth fill at the west end of the Inland Center bridge; therefore, the contractor will or did have to remobilize to install the air vac on the force main. 2 CHANGE ORDER NO. TWO - WEKA, Inc. CONSTRUCTION OF SEWER FORCE MAIN & COLTON UFT STATION IMPROVEMENTS AT INLAND CENTER DRIVE _ SEWER MAIN & SEWER ENCASEMENTS AT MILL STREET (SWOS-oS) [-21 S FREEWAY WIDENING (SEGMENT 3) BvOIlllS & Pumo Sewer Lift Station Caltrans was on a fast-track construction for the northerly portion of the Inland Center 1-8 bridge. The new pumps for the force main would not be installed prior to this portion of the bridge completion. At Caltrans direction, the contractor was required to provide and man standby pumps to expedite the transfer of sewage to the newly constructed force main. Put Hole Existinl! Sewer Lateral & Install Sewer Laterals S.F.R. During construction, it was discovered that (2) existing residents' sewers were connected to a sewer mainline that was within Caltrans right-of-way. It was necessary to pothole the utilities in "I" Street and the existing sewer laterals from each home to 1-9 facilitate in design of the new lateral tie-in in "I" Street. There were (2) residents at Esperanza Street and "I" Street that were connected to a mainline in Caltrans right-of- way. This line was abandoned. It was necessary to connect the house latemls to the mainline in'!,' Street. The existing latemls were located in the backyards of the residents. Install Sewer Maio & Lateral io Heoderson Laoe It was determined during construction that the business at the east end of Henderson 1-10 Lane was connected to a lateral that was in Caltrans right-of-way and to be abandoned. It was necessary to construct a mainline sewer in Henderson and tie into the mainline sewer in "I" Street. This new mainline would service the business. Reoair Sewer Force Main 1-11 After the new force main was installed in Inland Center Dr., a contractor relocating another utility damaged the new force main. The contractor was directed to repair the damaged force main. SUMMARY OF CONTRACT COSTS The estimated revised contract cost is as follows: Original Bid Amount. .................................. ........................$1,141,690.00 Contract Change Order No. One . . . . . . . . . . . . . .. . . .. . . .. . . . . . . . . . .. . . . . .$ 161,884.67 Contract Change Order No. Two. . . . . . . . . . . . . . . . . . . . . . . . . . . . .....................$ 299.000.50 Revised Construction Contract cost. . . . . . . . . . . . . . . . . . . . . . . . .. ....................$ 1,602,575.17 Additional time to complete Contract due to this Change Order.......................... 120 Working Days This change order represents 26.19 % of the original contract amount. 3 CHANGE ORDER NO. TWO - WEKA, lnc. CONSTRUcnON OF SEWER FORCE MAIN & COLTON LIFf STATION IMPROVEMENTS AT INLAND CENTER DRNE - SEWER MAIN & SEWER ENCASEMENTS AT MILL STREET (SWOS-oS) 1-215 FREEWAY WIDENING (SEGMENT 3) WEKA, INC. CONTRACTOR Accepted By: Title: Date: CITY OF SAN BERNARDINO DEVELOPMENT SERVICES Approved By: Date: Approved By: Date: Item No. 4 VALERIE C. ROSS Director of Development Services LORI SASSOON Assistant City Manager May 18, 2009