HomeMy WebLinkAbout56-Facilities Management CITY OF SAN BERORDINO - REQUESTYR COUNCIL ACTION From: Bert Murphy, Manager Subject: UPDATING, MODIFYING, IMPROVING CITY HALL LIGHTING Dept: Facilities Management Date: May 25, 1992 Synopsis of Previous Council action: None Recommended motion: 1. That the attached report on proposed updating, modifying and improving lighting in City Hall, prepared by Energy Controls and Concepts. dated May 12. 1992. be received and med. 2. That the Director of Public Works/City Engineer be directed to have plans. specification and estimates prepared for updating. modifying and improving lighting in City Hall. 3. That the City Administrator be instructed to develop a resolution for the purpose of borrowing $148,000 from the Sewerline Construction Fund to front the costs for the installation of the lighting project. The Sewer' Construction nd will be repaid over five years at 7% in er Contact parson: Bert Murphy Phona: 384-5244 Supporting data attachad: Yes Ward: FUNDING REQUIREMENTS: Amount: $148,000 Source: (ACCT. NO.) 001-092-56366 (ACCT. DESCRIPTION) City Hall Lighting Project Flnence: (LU AJr-_;._,-- Council Not81: 15.0762 Agenda Item No, 5IR 'CITY OF SAN BERORDINO - REQUEST ,:YR COUNCIL ACTION STAFF REPORT Facilities Management Division has actively sought and received several proposals aimed at reducing the cost of energy for City Hall. The objective of this project is to reduce electric lighting cost while maintaining adequate lighting levels. We feel this can be accomplished by replacing existing equipment with new energy efficient equipment, adding occupancy sensors, daylight overrides and other energy saving devices. This proposal has been reviewed by the Facilities Management Maintenance Section; Jim Sharp, Project Manager Economic Development Agency and Southern California Edison's Energy Services Department. The total project cost is $147,856 and the expected payback period is 36 months. At the completion of the project, the City will receive an estimated $11,000 rebate from Southern California Edison. The recommended funding is to obtain a five year loan in the amount of $147,856 from an existing city construction fund. Attached is a loan payment schedule that shows payments of $2,927.73 per month for five years at 7% A.P.R. The monthly energy savings by the project is estimated to be approximately $4,000 per month. The difference between the loan payment and the reduced energy consumption cost will provide a positive cash flow of approximately $1,000 per month. We believe this proposal is an excellent project and recommend serious consideration be given to fund and implement. 75-0264 - -,-~~~--- Loan/Annuity Amortization Schedul. r'" . . .;~......- ....,. -.-- ; ,--. ENERGY LOAN .-. Annual P~nt.ge Rate = 7.0000% PI' ine ip.l ;,w( 147856.00 I H,,,.,', ~ Pmt Payment Pr ine ipal Intwrest Total Ending Principal . Due Date Payment Payment Payment Balance JUL 01 92 2065.24 eE.2.49 2927.73 145790.76 2 AUG 01 92 2077.28 850.45 2927.73 143713.48 3 SEP 01 92 2089.40 838.33 2927.73 141624.08 4 OCT 01 9-' 2101. 59 826.14 2927.73 139522.49 5 NOV 01 92 2113.85 813.88 2927.73 137408.64 6 DEC 01 92 2126.18 BliH.55 2927.73 135282.4E. Subtotal 92 12573.54 4992.84 17566.38 7 JAN 01 93 2138.58 789.15 2927.73 133143.88 8 FEB 01 93 21St.lZIE. 776.67 2927.73 130992.82 9 MAF~ 01 93 2IE-3.b! 764.12 2927.73 12882"3.21 10 APR 01 93 2176.23 751.50 2927.73 12e.e.S2.98 11 MAY 01 93 2188.92 738,81 2927.73 124464.0f, 12 JUN 01 93 2201.69 726.04 2927.73 1222E.:2.37 13 JUL 01 93 2214.53 713.2l2l 2927.73 12l2l12147.84 14 AUG 01 '33 2227.45 700.28 2927.73 11782l21.2':; .~ SEF" 01 93 224121.44 687.29 2927.73 11557'3. '3~ >- IE, OCT 01 93 2253.51 574.22 2927.73 113326.44 17 NOV 01 93 2266.66 5€.1.0? 2927.73 11112159. ?E 18 DEC 01 ~" 2279.88 647.85 2927.73 ,11218779.90 .0 Subtota.l 93 2651212.55 863121.2121 35132.76 1"3 JAN 01 94 2293.18 634.55 2927.73 11215486.72- 20 FEB 01 94 231216.5€. 621. 17 2927.73 10418ll"J.16 21 MAP ., 'Sl4 232121.1211 61217.72 2927.73 10186121. 1~, 22 APF.' 01 94 2333.55 594.18 2927.73 99S26.6e ..;;..:, MAY 01 94 2347.16 58lZl.57 2927.73 97179.4__ 24 JUN 01 94 2360.85 566.88 2927.73 94818.5'3 -,~ JUL 01 94 2374.62 553. 11 2927.73 92443.97 -- 26 AUG 01 94 2388.47 539.26 2927.73 90055.50 27 SEP 01 94 2402.41 525.32 2927.73 87653.09 28 OCT 01 94 2416.42 511.31 2927.73 85236.67 2'3 NOV 01 94 243121.52 497.21 2927.73 8281216. 15 30 DEC 01 94 2444.69 483.1214 2927.73 8121361.46 Subtotal 94 28418.44 6714.32 35132.76 31 JAN 01 95 2458.95 468.78 2927.73 7791212.51 32 F"EB 01 95 2473.30 454.43 2927.73 75429.21 33 MAP 01 95 2487.73 440.1210 2927.73 72941.48 34 APP 01 95 251212.24 425.49 2927.73 70439.24 35 MAY 01 95 2!:i16.83 4UI.9121 2927.73 67922.41 36 JUN 01 95 2531. 52 396.21 2927.73 6539121.89 37 JUL 01 95 2546.28 _ 381. 45 <?927.73 62844.61 38 AUG 01 95 2561. 14 366.59 2927.73 6121283.47 3'3 SEP fli1 95 2576.1218 351.65 2927.73 5771217.3'3 40 OCT 01 95 2591. 1121 336.63 2927.73 55116.2'3 41 NOV 01 95 2606.22 321.51 2927.73 5251121.1217 42 DEe 01 95 2E.21.42 305.31 2927.73 4988B.E.';';; Subtotal 95 3121472.81 4659.95 35132.75 43 JAN 01 96 263E..71 291.02 2927.73 47251.94 44 FEB 01 96 2652.09 275.64 2927.73 44599.85 45 MAP 01 96 2667.55 2E.lll.17 2927.73 41932.29 4E APr;:' 01 '3E. 2683.12 244.E.1 2927.73 39249.17 47 MAY 01 ':':IE. 2598.78 228.95 2927.73 36550.3'? 48 JUN 01 '3E. 2714.52 213.21 2927.73 33835.87 49 JUL 01 9E 2730.35 197.38 2927.73 31105.52 5~ AUG 01 9E, 2746.28 181.45 2927.73 28359.24 51 SEP 01 '3E.. 27E.2.30 1€.5.43 2927.73 255'36.'34 OC1 01 ':tE. 2778.41 14':'.3:2 2'327.73 22818.53 -" 53 NO\' 01 ':IE" 2794.52 13::'.11 2927.73 2012123.':11 ~,4 DEC 01 9E 2810.92 116.81 2927.73 17212.99 Subtotal 95 32675.65 2457.10 35132.76 55 JAN 01 97 2827.32 100.41 2927.73 14385.67 5~ FEB 0l 97 2843.81 83.92 2927.73 11541.86 57 MAP 01 '37 28621.40 E.7.33 2927.73 eE.81.4E. 58 APF' 01 97 2877.1219 50.64 2927.73 581214.37 5'3 MAY 01 97 2893.87 33.85 2927.73 291121.50 60 JUN 01 97 2910.50 16.98 2927.48 0.00 Subte,tal 97 17212.99 353.14 17565.13 Grand Tc-,te;l 147855.0121 278217.55 175E.E.3.55 . ...'" '. -:,J..'~:~ ..-;-' -;', ~ .; ~:'._"!,"<:.;~;:, ..\~...'.:;.~> '1- a:u:. -<: ., .."'-.....~,- A. ....,..... ~)....c': ....f'if:l"" ,JI"'tf' !f11 ":..- ) . ~ :: :"~: ti.~~ . '~;":: \_~", ..f7';, ~..~ ~ ~ ~~ ..~!..._ . ~_"_~_ . .. ..{ ,., _, .." ~. ~ r 'W "~'. Y:" .:>-l':f;:; ,;' ";" '-~.,~ ~"'.- .... ""- "',"\,,, l~~'). '... ,;.c;"'/fJ!- . \'~'" "' "'",,.. ''''~!#''~....!'' ~', ':'o.~" '" ..:~~' ~~' ....,.,' +,- '. ....,,~ ~("'~ ~ ~ ,..' i~ ....\~ ~ ~ ....... ft":,., ...~.;.......'.~\ ';.. '." ,,~.~ '; ':'(:~('f:'~~';~-5'!:~:'~...~ ~1!:ttB.~"5f.~~". ,~ _.."" J'.., .;'~ ..._'..-_.f'~'~"""~""1('",,;-1,''''::_~~''') c... ..~, _ ... ..... <\ ">" "'_....~ "'''I!~''' .l'''''~-_7oiA.:: ~. ~ ~ . _' ," ~ '~1...;"""'it.......'\.""""~4',,, 'Y1-..~.'J-.,}. .;'~ . ~ '\' ~loo "t\' :'~I' .i-"'-~"":1I!. ;'~"~'(;l~' ~-:,::, ',;1. "':t~;.I. , ,foA " " ...,.. ''''( .....,..\.~ :'1;::, - _,' ;,{~r~.~.,.". V~>-: "i,. ~,( '0"', ~...... :., ,,:.y.~~, ~"l (~r'~'.,..~~~~ ;:\:~~~j' ~ . I... :.. p,'~J'.' ~.:::c< "........r~_..:<.'~. ~..~ ~....~, , .,.,..(' ,. .~ .. ~.~.i '.i<" ...~.,.,::'l;2" 'C;~t.T';-."'4." '~"-,... "". ,,' ( .'(' "'""-~""".~~\f~~).y~~,,,,~'~l.i.o!.'~l1:~ ',.\,Ii, ".~ '''-::: ~.y- : ~.i~-:' ~~.., .1:<: ;:~. ';~ "'\~~~~:"'i$ ;''' -,,' ,. ,'. ~ f'" ;\'~ ,:{ ..:.: ..,.\ ,-. l' :"'):...,,~;:r....~;. -.. ?.:';. ',. ..).' .- ."'. ,~-.~.. ~':. :-~~,; ". ~. ,/ .t-:: \ :....~..,.:..~':..}. ...~., ~ '-' ...-.\...... 'r ,fo..~~~...."'.....~;;~-"-;p.{-ij...4't,<.l1 )... V;. _....... .'...."" .;....,.. ;~... .;'" "'-.. ... "'.'" '" '-I -,.." ~." ~" . - ~. '''-'- "',i. ,~ '" ""i' ... .... ;. '" ." " ,~'. ~, .., ,.( ".r::..~ '.' .' .,' ,'., - ..;c,..... .... , ., ..'^ '!': ,. -' ~ .. ~ '''', ':"; <^,',>:, ~ <_ ...,."i' , ?,..... ;;_~:;'_. .~ ".il'''' .:" '..~-.~ -_. ~ .of. _"''';''''; " ;;,. ,t.' ~ .';". -..., " :<. ~~~i~ '':~~'';- t " t" ":;,.., ,,'j ~.:I""'~ ,,!<!'i~"t ~. :,,-' ...-; 'I ". l' .>.; ,0-' . ,0> iiii -. .' , " .I' ;... , ......... , , " . ~ , + .' '.- "'t., c ~ ...~' '>;'-' ......} }'. '" "Y.. ~! ~ ..~ , . !.-,. .,. ~1"'i" '- .'.. '-"': ~.~., ," '. .~ '.> " '-'J' , " -'f; ,'. -~ . , ;: , ' 'j. (. ," :'A-, .'. 'C ,'.' , , .~ '.-. . > .. ;''' . , . . ;,,<" -~'" .' , < . ,,'r' +. - ,. .. ~" ;'.<.: 0,;;'." '0'" '_::~t:,'-'~. >:, ;.< .~..."j.'~. ~t.: _,; ~ ~:~" - D . ~_~'e;. - ~.;(~ :~'" <i.'"....~:4" ,-" .' ."" ~ ~,~...."<. ~ 'J []. '., .<:<. ':"~ i .:: , : :i;,"~ .' 't'. ..'of ~ .' .~!-'.~ 1.. 0";.,< 'c.:l'.'~.::~~,~rl.. ~-t~; "'.1., ~ '. , . h;.. '" ... .~. ;,-..,,-' ".,- ~ ':. "'- .,.,. ~.. ,~ .. , .",' 'j:'-" .;., . -' n. > ~;! .,.-~ ~ "" .-, ., .:t. , < .' A_.. , , ., ..'~ -'"':' ~. .' "'_~ "'" .': ~. "t,.. ')...... . .'-> -"'f :.."!-'^..."..... v,,;.'" . ." ..'''' ;""'J --;." . .- .~ , .' ,,''''' , .V 1'1- ,\" '. SAN BERNARDINO CITY HALL BUILDING t, ,; .,' " :J.;- , 300 North "D " Street San Bernardino, CA 92418 -_.~, , ,[] '.'.<. \... . . ,- ~ " . ., ~ ! -:'.~, ." ...:~ r ,j ';',1\ , , ;:;~S .' - '";- J ;. ~.i; .... ID ..: ,,;,~~ ;.. ..'''~. .",*. '\.. ,<.\",~~, ';(',_ s .~ ~.,.J-~:;~:~' .;~~ :i. . ,."A"'~' ,'" . ".~ ~ -. ( {-..... .,...:. "_",,-! .l,.~ .... ".< ~' . ''.,-. -:)'.~:~ ~' , -.... ....., ~. _'1 :0- . '.;l"~l ;-,:-, , 4!;J"L' "-~- . ;: ";~ 1"( ; ~t '. .....~. ':",'" .: "'. -,,~, ~ ~., ',.,...~ . ., , ,. , . ~..., , -~- .~. ~ ,"'...... " " ; ., t," ~. ,. . - . r"~' ~~:::, '1': .. c' ,'. :::. "./ '::"'(,.1'. ,~ .~ ~: .' ,~.,'" ,"~' I', " "- " ,J . '.',,' ~. ....; J~'--'. ,~. ,OY'.1 .1- .,.... ....: '\-_ _ <, .:~ .. ~';.~.~~ 'I ,: --l . " ; r,~ '" ~ ",.~ "i- . ~ . ~ . ,0;" )' .>-,.. ,.~ '':i....'..., ~ <. ~..-.... " ...' , .,..... . ~ :t:~ ;1.. ~ 4' . _.. .... #' J, ~.... 'To.."I':. ....,.. ~. ~,.:t L,"' ,~'~', 't'o- .I' . ~', ,,';~::.1 ,~,,- ><~~"'~. .~..~.-.-.:~.;. J~';;~":~_:; ,\~, ~,.-.:.~ ',".< ,'t "" "."" "i:":j:::.'~ ." ~~'..:" :.~' .:... '._.,..... .', .. ." N <;." ,--~ ,"',;~, ~w~~~,'~:;'(::. ~;:: '. ; ~1.'."........i,;..~_~..,.~_..~.~...i.l..;.~,~.;..,;,.l.. .. ',;: ',; "A ",:i:, ~l<'.'~,.'~ i>:'~:;o';"-:' ~\ ~':~; .^:~~:.~ ", --,..r;;;...."!>>~,,: -' ~ ~_ ,~'~s.~;:~~..~f.'~,()a'~'-~; -~_J~.", '~''"' ;~~~~~~ ~ -,. .,.' ~~,~": 7"1:.~'. .': :.~t~,,'- )::;.:..;~ n' -.> t:~i;~~~.-""'''"" CA g?~Jll ..(.714) :P5'lppg. FAX (7~14) 335.ji715 ~:.,.-f'}:,~!n'.Yg!!tjji~ '.f ~".: """. . :. ".f . . '~..~ '~.~_.A ,::'~~"~.' \. . '... "'.~~ ~.';'~. ~ · ';' '~~ ' ;' , :;", .' 't . {~~ Lighting The Way.%.f\. Br.ighterFutiire/,,:," . I. '~~ ~~ ..... . ...... 111 ~., ~, .:; t......:~~~ '... "- '~'<jT~~~~ .~ , -- }. _.>1" .4 "'"'' - , , - .' .- ~'. J" , .~ ,. ,.' ID J' ^' ~" f' /' '";"\ '''- < ~.\ , " , ~ .. ''':,.., ;', .' '. ., , . , .,.' .' ." . , ~ " m ~w -":;. - ". -1.", ; , . . :1,,(- _.-,,~ ~~ '. ~c ..' .-...- , r;'" . , " ~. , , w ~1jI l.lI ., " .. " .~ :. ., " .:.:~ . ^ " ,. ~:i< ,. '.0 " c' , .''-' '<'1" .; ,,,"; " , , Y'., :1.,;..:. , ,,-::'-, '" '-~;'; .... ,".... Q ....... > , '- .' o , ~. ~ " '.. ,. ,. .'>" " " , ._Q , ,~' .1 o , .A , '". ~ o '. " '. ,. I' .1.,.'...... ,.<J .~~. 1758.8 g'ia'],ge T ~I'Jane.~ Re<;liands, j,: l - .' ~.. \%I ,. ~7 .~ " . f" "0 , ,: ...r;,:....~~~.~. <~~ .~ - . ,:,;;-"':';:;.'" y~ .' ..~ , . ';, ;.;.i . ~~, '''''- \. '~--'" ~; " " '''-' ~i-' '). i'-r" ,~ ..^ ,. , ~~. ': '_Ii ~",',. .,";'... ~~ -": ::~/..... ..;. -.'- .. .. ~ 1 ... .~ ... --, .' ~ ~ '...... , , .' ,. j. :."...,., '.., '.:~ " l ~, " \- ~:r " . ".Jf>; ..,;Y" ~, . . ~, \ ~. ,. - . .' " \(~::: .' '\.' JI.,"" ;;~'; C., . '....\. " ~ . " . "'. '''-' -. , ,. . " ~. .,. , " i.'; "'. ~ , , .. oJ,,/" . ~. ~. , ;,'" ....' .: " ... , . , ;:..... , , , .' . . , ~ -... ;,; ,,' , .' ~ :. t .' .(i.:: .,. . ~' i"",.. .~..... <!', ,. , , .> , .....l. ,. .~"',;c -' t' ..:~ (!~r ...... " oJ-.:.,. y ;"':i,.. .~, .r ..,.1'^'~ ~.'.. .~\.'-! ~~,~ '--,! , .. .~" "~,'l .- > y l~ ...:". .'i ~'...:- ,.' ....~;... < ." c ~:"t ->" 'i ., , ..it :_.l . - - ~ Energy Controls & Concepts - .. .... ... 1758-B Orange Tree Lane. Redlands, CA 92374. (714)335-1699. FAX (714)335-5715 .... ... .. .. Prepared For: Mr. Bert Murphy Manager Facilities Management Department May 12,1992 .. aM .. CC: Mr. Jim W. Sharp Project Manager Economic Development Agency lIIIl .. lIIIl Project: Address: San Bernardino City Hall Building 300 North "0" Street San Bernardino, CA 92418 ... .. .. lIIIl Objectives: Update, modify and improve existing lighting equipment with new energy efficient replacements. Increase the lamp life and reduce electrical costs. Improve existing light levels as well as lamp life. Provide client a reasonable time frame for recapturing initial costs. Coordinate energy audits with the respective utility company in the area(s). Estimate utility rebates (if any) and cost savings. .. aM ... .. General Specifications: Includes energy efficient fluorescent lamps, electronic ballasts and controls in specified areas. Also includes compact fluorescent lamps in place of incandescents / floods and some replacement of diffusers. "" .. .. .. .. .. The following data was compiled using estimated burn times for all the various areas in this facility. You will note that burn times, lighting specifications and applications will vary in each area. In addition, please note that lamp wattage is computed based on lamp/ballast types in accordance with specifications provided by ANSI (the American National Standards Institute), the primary source by which electrical standards and measurements are assessed, and manufacturers' specifications. .. .. .. .. These assumptions are believed to be as close to accurate as can possibly be assessed based on our various sources of information that we deem reliable. Estimations in burn time were gathered from various sources at this facility. .. .. .. .. ... ... ... ... ... II. ... Project Areas II. Area 1 ... Ai'ea 2 ... Area 3 Area 4 ,. Area 5 ... Area 6 Area 7 II' Area 8 IW Area 9 Area 10 II' Area 11 IW Area 12 II' Area 13 ... Area 14 Area 15 ... Area 16 ... Area 17 '" Area 18 .. Area 19 Area 20 '" Area 21 .. Area 22 Area 23 ,.. Area 24 .. Area 25 !I" Area 26 .. Area 27 .. Area 28 .. Area 29 Area 30 '" Area 31 ... Area 32 "" Area 33 Area 34 .. '" Area 35 ... Area 36 Area 37 II" .. Description 6th Floor - Copy & Reception 6th Floor - Break Rooms 6th Floor - Administration, Conference & Storage 6th Floor - Sister City Showcase 6th Floor - City Attorney 6th Floor - City Attorney 6th Floor - Administration I Mayor I Conference 6th Floor - Administration Halls 6th Floor - Mayor's Office 6th Floor - Mayor's Office 6th Floor - Conference Room I Mayor's Suite 5th Floor - Break Rooms 5th Floor - Water Department 5th Floor - BP I Storage I Copy I Conference 5th Floor - Water Department 5th Floor - Wa.ter Department I Circulation 5th Floor - Water Board Control Room 4th Floor - Occupational Health I Risk Management 4th Floor - Occupational Health I Risk Management 4th Floor - OH Copy Room 4th Floor - Occupational Health I Risk Management 4th Floor - Public Services 4th Floor - Public Services I Finance 4th Floor - Public Services I Conference" A" & "B" I Break Room I Copy Area I Filing 4th Floor - Finance I Break Room 4th Floor - Finance I Purchasing 4th Floor - Finance I Purchasing 4th Floor - Finance I Storage 3rd Floor - Planning I Public Works 3rd Floor - Planning I Public Work:; 3rd Floor - Storage Rooms & Break Rooms 3rd Floor - Planning I Public Work:; 3rd Floor - Planning I Public Works-Storage 3rd Floor - Planning I Circulation 2nd Floor - City Treasurer 2nd Floor - City Treasurer-Storage 2nd Floor - City Treasure( I StOI age I Filing Rooms .. - .. .. .. ... ".. Area 38 .. Area 39 Area 40 .. Area 41 .. Area 42 ".. Area 43 .. Area 44 Area 45 '" Area 46 .. Area 47 I'" Area 48 .. Area 49 '" Area 50 Area 51 .. Area 52 '" Area 53 .. Area 54 '" Area 55 Area 56 .. Area 57 !I' Area 58 . Area 59 II. Area 60 ,. Area 61 II. Area 62 "" Area 63 IlIII Area 64 Area 65 ,.. Area 66 ill Area 67 Area 68 .. Area 69 .. Area 70 Area 71 .. Area 72 II. Area 73 Area 74 I'" ill Area 75 Opt. 1 Area 75 Opt. 2 .. .. 2nd Floor - City Clerk 2nd Floor - City Clerk-Storage 2nd Floor - Civil Service 2nd Floor - Civil Service-Storage Mezzanine - Council Offices Mezzanine - Council Offices Mezzanine - Council Offices Mezzanine - Conference Mezzanine - Conference 1 st Floor - Lobby 1 st Floor - Council Chambers 1 st Floor - Council Chambers 1st Floor - Council Chambers 1 st Floor - Council Chamber I Audio Visual 1 st Floor - Council Chambers 1st Floor - Council Chambers (Wall Washers) Basement - EOC Basement - B57 I Break Room I Mail Room Basement - Centrai Services Basement - Central Services I Office Rooms Basement - Central Services Basement - MIS I Building Management Basement - MIS I Building Management Basement - MIS I Building Management Penthouse - Mechanical Penthouse - Mechanical Stairwells Common - Elevators Common - Circulation Common - Circulation Common - Circulation Common - Electrical Rooms Common - Ditto Rooms I Storage Common - Restrooms Common - Restrooms I Janitorial Common - Elevators Common - Exit Signs Perimeter Luminaires I Ambient Light Sensing I Continuous Dim Perimeter Luminaires IIR Occupancy Sensing I Daylight Overri - ... - ... - ... Areal 6th Floor - Copy & Reception ... "" Specifications: 2' x 4' Drop-Ins 14 lamp I F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-41 OOks Lamps, Replace lamps 2 for 4 and clean fixtures. Add One Passive LA. Sensor. iI.. ... "" Anticipated Results: Will equal existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve. ... ioo ~ iii Fixture I Lamp Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 2 4 F40CW/SS 156 $1,95 15000 (20000) 0.105 9 2730 ... ... II' Ii. ~ II. II" ll. Comparitive Cost Light Eoergy Lamps Labor Cooling T olal Annual Cost 89.43 0.00 0,00 19.12 108.55 II" .. II" i. Estimated Annual Cost Savings $71.53 .. i. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... II. II" .. II" ... "" ... Page 1 Prooosed 2 2 F032T8-41 ks 76 $2.50 26000 0,105 9 1911 30.50 0.00 0,00 6.52 37.02 0.66 Percent (%) 852 290 561 .. .. .. .. "" iii Area 2 6th Floor - Break Rooms ... ... 2' x 4' Drop-Ins 12 lamp I F40CW/SS - 34 Watts Specifications: ,.. i... Retrofit fixtures with electronic bailasts and F032-4100ks Lamps, Replace lamps 2 for 2 & clean lixlUre, Add Two Passive I.R, Sensor. Use remote bailast. Recommendations: "" iii Anticipated Results: Will increase existing light levels. Lamp lile wiil increase significantly, Bailast heat wiil be greatly reduced, Color rendering will also improve. ... iii "" .. Existin2 5 2 F40CW/SS 78 $1.95 15000 (20000) 0,105 9 2730 "" ill Fixture I Lamp Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fIxture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) "" i.. "" i.. "" . Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 111.79 0,00 0,00 23.90 135.69 ., "" .. ... .. Estimated Annual Cost Savings $69.93 .. ill Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. '"' iii I .. Ii. ; ... iii Page 2 Proposed 5 2 F032T8-41 ks 54 $2.50 26000 0.105 9 1911 54.18 0.00 0.00 11.58 65.76 0.52 Percent (%) 1065 516 549 .. .. .. ... .. ... Area 3 6th Floor - Conference & Storage "" ill Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CWISS - 34 Watts .. Recommendations: Retrofit fixtures with HBF elec\ronic: ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 & clean fixture, Replace diffusers, ... .. .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, "" ill .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existinl! 9 HBF Ballast 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 IllI '"' IllI '"' .. .. ill '"' Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 402.46 0.00 0.00 86,03 488.48 .. .. lit .. $250.50 IllI Estimated Annual Cost Savings .. III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. III .. III .. .. .. Page 3 .. Prowsed 9 2 F032T8-41 ks 76 $2,50 26000 0,105 9 2730 196.07 0.00 0.00 41.91 237,98 0.51 Percent (%) 3833 1867 1966 - - "" .. .. .. Area 4 6th Floor - Sister City Showcase ... II. Specifications: 4' Strips I 2 lamp f F40GWfSS - 34 Watts "" Recommendations: Retrofit fixtures with electronic ballasl:; and F032-4100ks Lamps. .. Replace lamps 1 for 2, Use remote ballast. ... .. "" .. "" .. "" .. !'" ... "" .. "" .. !'" . "" .. "" . "" .. ... .. - .. ... lit Anticipated Results: Will increase existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will also improve, Fixture / Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type ES-Ballast Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existing 12 2 F40CW/SS PrOOQsed 12 1 F032T8-41 ks 28 $2,50 26000 0.105 9 2730 72 $1,95 15000 (20000) 0.105 9 2730 Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 247,67 0.00 0.00 52,94 300,60 96.31 0.00 0.00 20.59 116.90 Estimated Annual Cost Savings $183.70 0.61 Percent (%) Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 2359 917 1441 Page 4 .. .. I. .. .. .. 6th Floor - City Attorney AreaS ,. III Specifications: 2' x 4' Drop-Ins 14 lamp I F40CW/SS - 34 Watts "" III Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 & clean fixture, Replace all diffusers. . , "" .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve. II' .. !II .. Fixture I Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 55 4 F40CW/SS 156 $1.95 15000 (20000) 0.105 9 2730 ; .. .. . .. .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 2459.46 0.00 0.00 525,71 2985,17 .. i .. .. .. .. Estimated Annual Cost Savings $1,530.85 i .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. .. " < ... .. .. Page 5 .. Prooosed 55 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 1198.20 0,00 0.00 256,11 1454.31 0.51 Percent (%) 23423 11411 12012 .. - - .. - .. .. Area 6 6th Floor - City Attorney .. Specifications: 2' x 2' Drop-Ins - U-tubes I 2 lamp I FB40CW - 40 Watts .. Recommendations: Retrofit fixtures with electronic ballasts and F017-4100ks Lamps. Replace lamps 2 for 2. Add specular reflectors. .. .. .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will improve, .. .. .. .. .. Fixture I LamD Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 6 2 FB40CW 92 $5,85 18000 0.105 9 2730 PrODOsed 6 2 F017T8-41ks 38 $3.85 26000 0.105 9 2730 .. .. .. ill .. .. ill Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 158,23 0.00 0,00 33.82 192.05 65.36 0.00 0.00 13.97 79,33 . .. .. .. ill Estimated Annual Cost Savings $112.73 0.59 Percent (%) .. .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 1507 622 885 .. .. .. ... .. ... Page 6 .. - - ... .. .. .. Area? 6th Floor - Administration I Mayor I Conference .. .. 2' x 4' Drop-Ins 14 lamp I F40CW/SS - 34 Watts Specifications: .. Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and ciean fixture. .. .. .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, ~ .. ~ lIIII Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 24 4 F40CW/SS 156 $1.95 1 5000 (20000) 0.105 9 2730 .. .. .. lIIII .. lIIII .. .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 1073.22 0.00 0,00 229.40 1302.62 .. .. .. .. Estimated Annual Cost Savings $668.01 .. .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours iii .. ... .. .. ... Page 7 ... Prooosed 24 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 522,85 0.00 0.00 1 t 1,76 634.61 0.51 Percent (%) 10221 4980 5242 .. - .. .. .. .. .. .. Area 8 6th Floor - Administration Halls Specifications: 2'x 4' Drop-Ins I 2 lamp f F40CW/SS - 34 Watts .. .. Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 2, Clean fixtures. ... lit Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will improve. .. lit ... .. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existine 3 2 F40CW/SS 78 $1.95 15000 (20000) 0.105 9 2730 .. .. - lit .. .. .. lit Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 67.08 0,00 0,00 14.34 81.41 !lit .. !Ill .. Estimated Annual Cost Savings $14.61 - .. , .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours - .. "'" .. ... Page 8 .. Proposed 3 2 F032T8-41 ks 64 $2,50 26000 0.105 9 2730 55.04 0.00 0,00 11.76 66,80 0.18 Percent (%) 639 524 115 - - ... - ... .. ... .. ... .. '"' .. .. .. .. . .. . .. .. ... . '"' .. .. .. .. .. ... .. .. .. toO .. ... .. Area 9 6th Floor - Mayor's Office Specifications: 2 X 4' Surface Box I 4 lamp I F40CW/SS - 34 Watt Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps, Replace lamps 4 for 4, Clean fixture thoroughly. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will improve, Fixture / LamD Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (bours) Existing 1 4 F40CW/SS 156 $1,95 15000 (20000) 0.105 9 2730 Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 44,72 0.00 0.00 9.56 54.28 Estimated Annual Cost Savings $16.70 Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... Page 9 .. PrODOsed 1 4 F032T8-41 ks 108 $2.50 26000 0.105 9 2730 30.96 0,00 0.00 6.62 37.58 0.31 Percent (%) 426 295 131 ... ... ... .. .. ill Area 10 6th Floor - Mayor's Office III ill Specifications: 75 Watt Indoor Flood Lamps (large ceiling cans) III Recommendations: Retrofit fixtures with 13 Watt Quad PAR-38 Lamps, .. III ... Anticipated Results: Will equal existing light levels. Lamp life will increase approximately 500%. Lamp heat will be reduced significantly. III ill III .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 4 1 75W Indoor Flood 75 $2.95 2000 0.105 9 2730 III .. .. ill .. ... .. ill Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 85,99 0.00 0.00 18.38 104,38 .. ilII .. ill Estimated Annual Cost Savings $82.81 .. .. "" Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. .. ... .. ... Page 10 .. PrODOSed 4 1 13 Watt Quad 15.5 $4.25 10000 0.105 9 2730 17,77 0,00 0.00 3,80 21.57 0.79 Percent (%) 819 169 650 - .. ... .. ... 11oo Area 11 6th Floor - Conference Room I Mayor's Suite "" III Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts "" ill Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly, "" .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced. Color rendering will also improve. "" IiII II' iii Fixture I Laffin Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 15 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 1300 l'" . "" ill l'" ill l'" . Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 319.41 0.00 0,00 68,27 387.68 "" . III .. Estimated Annual Cost Savings $198.81 "" IiII "" . Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. .. ... Page 11 .. Prooosed 15 2 F032T8-41 ks 76 $2.50 26000 0,105 9 1300 155.61 0.00 0.00 33.26 188.87 0.51 Percent (%) 3042 1482 1560 - - - .. '" III Area 12 5th Floor - Break Rooms "" .. Specifications: 2' x 4' Drop-Ins I 2 lamp I F40CW/SS - 34 Watts r iii Retrofit fixtures with electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 2 and clean fixtures. Add one Ultra-Sonic Sensor. Use remote ballast. Recommendations: '... .. Anticipated Results: Will increase existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, ... .. II .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 4 2 F40CW/SS 78 $1.95 15000 (20000) 0.105 9 2730 II III IJII' ... !II' .. ... III Comparitive Cost Light Euergy Lamps Labor Cooling Total Annual Cost 89.43 0,00 0.00 19,12 108.55 r .. !II' III Estimated Annual Cost Savings $55.95 !II" III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours "" .. '" ... .. .. ... ... ... Page 12 PrOOQsed 4 2 F032T8-41 ks 54 $2.50 26000 0.105 9 1911 43.34 0.00 0.00 9.26 52.61 0.52 Percent (%) 852 413 439 .- - - ... "" ... '"' ... Area 13 5th Floor - Water Department Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts :,. .. Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-41 OOks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly. 1,.. ... Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, I"' .. '"' .. Fixture I LamD Analvsis Fixture Quanlity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rale Months of Cooling Annual Burn Time (hours) Existing 94 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 ,. .. I"' ill '"' III '"' .. Comparilive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 4203.44 0.00 0,00 898.48 5101,92 - '"' .. '"' .. Estimated Annual Cost Savings $2,616.37 "" .. '"' .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Redut.1ion - Annual Kilowatt Hours "" .. ,.. .. ... .. Page 13 PrODOSed 94 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 2047.83 0.00 0.00 437.72 2485,55 0.51 Percent (% ) 40033 19503 20530 - - - ... ... .. ... Area 14 5th Floor - BP I Storage I Copy I Conference .. Specifications: 2' x 4' Drop-ins I 4 lamp I F40CW/SS - 34 Watt "" .. Retrofit fixtures with electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4. Clean fixtures thoroughly. Add 4 Ultra-Sonic Occupancy Sensors, Recommendations: . .. .. Anticipated Results: Will have a slight decrease in existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will be improved, .. .. "" III Fixture I LaffiO Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fiXture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existing 14 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 .. III .. III ... III . "" Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 626,04 0.00 0,00 133,82 759.86 .. , .. .. .. .. Estimated Annual Cost Savings $541.64 ... .. "" Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. ... .. , ... iIio ... Page 14 .. Prooosed 14 2 F032T8-41 ks 64 $2.50 26000 0.105 9 1911 179.79 0,00 0.00 38,43 218,22 0.71 Percent f%) 5962 1712 4250 - - - ... - . Area 15 5th Floor - Water Department ... 110 Specifications: 2' x 2' Drop-Ins - U-tubes I 2 lamp I FB40CW - 40 Watts ... Recommendations: Retrofit fixtures with electronic ballasts and F017-41 OOks Lamps. Replace lamps 2 for 2, Add specular reflectors. Remote ballast 50%, .. ... lIII Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will improve. I!IO .. ... .. "" 110 Fixture I Lamn Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 6 2 FB40CW 92 $5.85 18000 0.105 9 2730 Prooosed 6 2 FOl7T8-41 ks 38 $3,85 26000 0.105 9 2730 I!IO .. ... ill .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 158,23 0.00 0.00 33.82 192.05 65.36 0,00 0.00 13,97 79.33 ... .. , ... . .. Estimated Annual Cost Savings $112.73 0.59 Percent (%) .. .. ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 1507 622 885 .. "" .. ... ... ... Page 15 ... - - - - ... . Area 16 5th Floor - Water Department I Circulation ... .. Specifications: 2'x 4' Drop-Ins i 2 lamp I F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps. Replace lamps 2 for 2, Clean fixtures thoruoghly. Remote ballast 50%. .. "" .. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve, .. .. .. ill Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) ExistiQg 12 2 F40CW/SS 78 $1.95 15000 (20000) 0,105 9 2730 "" .. .. .. "" ill .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 268,30 0,00 0.00 57,35 325,65 .. .. .. .. .. Estimated Annual Cost Savings $75.15 .. .. ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. .. .. ... Page 16 ... Proposed 12 2 F032T8-41 ks 60 Avg. $2.50 26000 0,105 9 2730 206.39 0,00 0.00 44,12 250.50 0.23 Percent (%) 2555 1966 590 - - - .. - .. Area 17 5th Floor - Water Board Control Room .. .. Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with H8F electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly, .. .. III Anticipated Results: Will equal existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced. Color rendering will also improve, .. .. .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 4 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 II .. III .. .. .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 178,87 0,00 0.00 38,23 217,10 .. .. III .. .. Estimated Annual Cost Savings $111.33 .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours III .. ... .. ... .. ... Page 17 .. Prooosed 4 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 87,14 0.00 0.00 18,63 105.77 0.51 Percent (%) 1704 830 874 - .. ... ... ... ... Area 18 4th Floor - Occupational Healtrll Risk Management ... '" Specifications: 2' x 4' Drop-Ins I 4 lamp I F4QCW/SS - 34 Watts ... .. Recommendations: Retrofit fixtums with HBF electrrJnic ballasts and F032-41 OOks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly. ... .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will also improve. ... .. .. .. Fixture / Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Mnnths of Cooling Annual Bum Time (hours) Existing 18 4 F40CW/SS 156 $1.95 15000 (20000) 0.105 9 2730 ... .. ... .. ... ill .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 804.91 0.00 0,00 172.05 976,96 .. .. ... .. Estimated Annual Cost Savings $501.01 .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (alter completion) Estimated Reduction - Annual Kilowatt Hours II' .. ... .. ... 110 ... Page 18 - Prooosed 18 2 F032T8-41 ks 76 $2.50 26000 0,105 9 2730 392.14 0.00 0.00 83.82 475.96 0.51 Percent (%) 7666 3735 3931 - - .. - .. ... Area 19 4th Floor - Occupational Health I Risk Management .. lilt Specifications: 2' x 4' Drop-Ins! 4 lamp I F40CWISS - 34 Watts .. lilt Recommendations: Retrofit fixtures with HBF electronic l)allasts and F032-4100ks Lamps. Replace lamps 2 lor 4 and clean fixtures thoroughly. .. .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. .. .. .. .. Fixture I Laffin Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Mooths of Cooling Annual Burn Time (hours) Existing 9 4 F40CWISS 156 $1.95 15000 (20000) 0.105 9 2730 .. .. .. .. .. .. III .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 402.46 0,00 0,00 86,03 488.48 .. .. .. .. Estimated Annual Cost Savings $250.50 . .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. .. lilt ... .. ... Page 19 too PrODQsed 9 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 196.07 0.00 0.00 41.91 237,98 0.51 Percent (%) 3833 1867 1966 ,- - .. .. .. .. Area 20 4th Floor - OccupatIOnal Health-Copy Room .. ill Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts .. ill Recommendations: Retrofit fixtures with HBF eleCtronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 Md Clean tixtures thoroughly. .. ill Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. 11II .. \III III Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 1 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 .. .. i 11II .. ... ... ... . Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 44.72 0.00 0.00 9,56 54.28 . ,.. .. 11II . Estimated Annual Cost Savings $35.77 !III .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours !III . !III ... ... .. - ... Page 20 ... PrOOQsed 1 2 F032T8-41 ks 76 $2.50 26000 0.105 9 1911 15.25 0.00 0,00 3.26 18,51 0.66 Percent (%) 426 145 281 - - - - - - Area 21 4th Floor - Occupational Health I Risk Management ... .. Specifications: 2'x 4' Drop-Ins 12 lamp I F40CW/SS - 34 Watts "'" .. Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 2, Clean fixtures thoruoghly, "'" .. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will improve. "'" .. .. ill Fixture I Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existinl! 2 2 F40CW/SS 78 $1,95 15000 (20000) 0.105 9 2730 .. .. .. ... .. . .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 44.72 0,00 0.00 9.56 54,28 . . "'" ... Estimated Annual Cost Savings $9.74 .. ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. "'" .. .. .. ... Page 21 .. Proposed 2 2 F032T8-41 ks 64 Avg. $2.50 26000 0,105 9 2730 36.69 0.00 0.00 7.84 44.53 0.18 Percent (%) 426 349 76 - ... - ... .. Area 22 4th Floor - Public Services .. .. Specifications: 2' x 4' Drop-Ins! 4 lamp I F40CW!8S -. 34 Watts .. Recommendations: Retrofit fixtures with HBF electronic ballasts and FC32-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly. .. .. .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. .. .. .. .. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existing 44 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 .. .. .. .. ... .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 1967.57 0.00 0,00 420,57 2388.13 .. .. - III Estimated Annual Cost Savings $1,224.68 II' .. Estimated Annual Kilowatt Usage (existing) Estimated Anl1uai Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. .. ... ... .. ... Page 22 .. Prooosed 44 2 F032T8-41 ks 76 $2.50 26000 0,105 9 2730 958.56 0.00 0,00 204.89 1163.45 0.51 Percent (%) 18739 9129 9610 - - .. - - - .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. - .. - .. - .. - .. - .. - .. Area 23 4th Floor - Public Services I Finance Specifications: 2' x 2' Drop-Ins - U-tubes i 2 lamp I FB40CW - 40 Watts Recommendations: Retrofit fixtures with electronic ballasts and F017-4100ks Lamps. Replace lamps 2 for 2. Add specular reflectors. Remote ballast 500/0. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve, Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 17 2 FB40CW 92 $5.85 18000 0,105 9 2730 Proposed 17 2 F017T8-41ks 38 $3.85 26000 0.105 9 2730 Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 448,32 0,00 0.00 95.83 544,15 185.18 0.00 0.00 39,58 224.76 Estimated Annual Cost Savings $319.39 0.59 Percent (%) Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 4270 1764 2506 .. _ Page 23 ... ... ... - .. lit Area 24 4th Floor - Public Services I Cont. A & B I Break I Copy I Filing .. .. Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts .. III Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 & clean fixture, Add Five Ultra-Sonic Occupancy Sensors, Recommendations: .. .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will also improve, .. .. .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 23 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 . III .. !III . .. III - Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 1028.50 0.00 0,00 219,84 1248,34 .. .. .. !III . Estimated Annual Cost Savings $822.63 !III .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. ... .. lit ... Page 24 .. PrODOsed 23 2 F032T8-41 ks 76 $2,50 26000 0.105 9 1911 350.74 0.00 0,00 74,97 425.72 0.66 Percent (%) 9795 3340 6455 - ,- - '... .. ... Area 25 4th Floor - Finance Break Room .. Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts .. .. Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 & clean fixture. Add One Ultra-Sonic Occupancy Sensors. Recommendations: ... .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. .. .. ... Fixture I Lamp Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 5 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 . .. . ... . ... . ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 223,59 0,00 0,00 47.79 271.38 . .. .. .. .. Estimated Annual Cost Savings $178.83 ... .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. ... .. ... Page 25 .. PrOpOsed 5 2 F032T8-41 ks 76 $2.50 26000 0,105 9 1911 76.25 0.00 0.00 16.30 92.55 0.66 Percent (%) 2129 726 1403 - - - .. - .. Area 26 4th Floor - Finance I Purchasing - .. Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts - Recommendations: Retrofit fixtures with H8F electror.iG ballasts and F032-4100ks Lamps, Replace lamps 2 tor 4 and clean fixtures thoroughly. .. .. .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced. Color rendering will also improve. .. .. .. .. Fixture I Lamp Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 40 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 - .. .. .. .. .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 1788,70 0.00 0.00 382,33 2171.03 .. .. .. .. Estimated Annual Cost Savings $1,113.35 .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. ... ... .. ... Page 26 ... Prooosed 40 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 871.42 0,00 0,00 186.27 1057,68 0.51 Percent (%) 17035 8299 8736 .. - .. .. .. .. Area 27 4th Floor - Finance I Purchasing ... .. Specifications: 75 Watt Indoor Flood Lamps (Track Lights) ,. Recommendations: Retrofit fixtures with 13 Watt Quad PAR-38 Lamps, .. !II .. Anticipated Results: Will equal existing light levels, Lamp life will increase approximately 500%. Lamp heat will be reduced significantly. !II III .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 7 1 75W Indoor Flood 75 $2,95 2000 0,105 9 2730 .. !II ill !II III !II ill '" .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 150.49 0,00 0,00 32.17 182,66 ill .. !II .. Estimated Annual Cost Savings $144.91 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours !II .. ... .. II" .. ... .. Page 27 Proposed 7 1 13 Watt Quad 15.5 $4,25 10000 0.105 9 2730 31.10 0.00 0.00 6,65 37,75 0.79 Percent (%) 1433 296 1137 - - - .. - .. Area 28 4th Floor - Finance Storage '"' IiII Specifications: 2' x 4' Drop-Ins f 4 lamp I F40CW/SS - 34 Watts '"' IiII Retrofit fixtures with H 8F electronic ballasts and F032-4100ks Lamps. Replace lamps 2 fer 4 and clean fixtures. Add Three Ultra-Sonic Occupancy Sensors, Recommendations: .. IiII Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. .. IiII .. III Fixture I Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 9 4 F40CW/SS 156 $1,95 15000 (20000) 0.105 9 2730 '"' IiII .. IiII .. IiII .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 402.46 0.00 0,00 86,03 488.48 "" .. '"' IiII Estimated Annual Cost Savings $321.90 .. IiII Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. '"' .. '"' .. ... Page 28 too Prooosed 9 2 F032T8-41 ks 76 $2.50 26000 0.105 9 1911 137.25 0.00 0.00 29.34 166.58 0.66 Percent (%) 3833 1307 2526 - - - ... - ... '" ill '" ... - ... !II . !II III '" .. "" III !II ... .. .. .. ... - ... - . ... ... - ... - ... ... ... Area 29 4th Floor - Finance Storage Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Walts Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures, Add Three Ultra-Sonic Occupancy Sensors. Recommendations: Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 9 4 F40CW/SS 156 $1.95 15000 (20000) 0.105 9 2730 Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 402,46 0.00 0.00 86,03 488.48 Estimated Annual Cost Savings $321.90 Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours Page 29 Proposed 9 2 F032T8-41 ks 76 $2.50 26000 0.105 9 1911 137.25 0.00 0.00 29,34 166.58 0.66 Percent (%) 3833 1307 2526 - - - ... ... "" Area 30 3rd Floor - Planning 1 Public Works "" III Specifications: 2' x 4' Drop-Ins 14 lamp 1 F40CW/SS - 34 Watts "" Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly. III "" .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat wili be greatly reduced, Color rendering will also improve, "" III "" .. Fixture I LamD Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existinl! 103 4 F40CW/SS 156 $1,95 15000 (20000) 0.105 9 2730 "" .. "" .. "" .. .. III Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 4605.89 0.00 0.00 984,51 5590.40 .. .. ... III Estimated Annual Cost Savings $2,866.87 .. .. Estimated Annua! Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours "" III ... III ... .. ... Page 30 ... PrODOsed 103 2 F032T8-41 ks 76 $2.50 26000 0,105 9 2730 2243.90 0.00 0.00 479,63 2723,53 0.51 Percent (%) 43866 21370 22495 - - .. .. .. ill Area 31 3rd Floor - Planning / Public Works (storage rooms & break rooms) "" ill Specifications: 2' x 4' Drop-Ins / 4 lamp / F40CW/SS - 34 Watts "" ... Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and clean fixtures, Add Three Ultra-Sonic Occupancy Sensors, Recommendations: .. II Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. "" It II' ... Fixture I Laffin Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existinl! 18 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 "" Iii "" It II' ... II' It Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 804,91 0,00 0,00 172.05 976.96 .. II .. II Estimated Annual Cost Savings $643.79 "" It Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. II .. .. ... .. .. Page 31 ill Prooosed 18 2 F032T8-41 ks 76 $2,50 26000 0,105 9 1911 274.50 0,00 0.00 58.67 333.17 0.66 Percent (%) 7666 2614 5052 .. .. "" .. .. .. Area 32 3rd Floor - Planning I Public Works .. .. Specifications: 2' x 2' Drop-Ins - V-tubes I 2 lamp I FB40CW - 40 Watts .. Recommendations: Retrofit fixtures with electronic ballasts and F017-4100ks Lamps. Replace lamps 2 for 2. Add specular reflectors. ... "" ... Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve. "" .. .. .. ... Fixture I LamD Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 7 2 FB40CW 92 $5,85 18000 0.105 9 2730 Prooosed 7 2 F017T8-41ks 38 $3,85 26000 0.105 9 2730 .. ... .. ... .. !III Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 184.60 0.00 0.00 39.46 224,06 76.25 0,00 0,00 16.30 92.55 ... .. .. "" .. Estimated Annual Cost Savings $131.51 0.59 Percent (%) "" iIII III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 1758 726 1032 .. .. .. .. III .. Page 32 III - - ,- - ... ... Area 33 3rd Floor - Planning I Public Works (storage) .. .. Specifications: 2' x 2' Drop-Ins - U-tubes I 2 lamp I FB40CW - 40 Watts .. Recommendations: Retrofit fixtures with eiectronic ballasts and F017-4100ks Lamps, Replace lamps 2 for 2, Add specular reflectors, Add One Ultra-Sonic Occupancy Sensor. III ... - Anticipated Results: Will equal existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will improve, .. .. .. .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 4 2 FB40CW 92 $5,85 18000 0,105 9 2730 Prooosed 4 2 F017T8-41 ks 38 $3.85 26000 0.105 9 2730 .. .. .. .. .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 105.49 0,00 0,00 22,55 128.04 43,57 0.00 0.00 9.31 52.88 .. .. .. ... .. Estimated Annual Cost Savings $75.15 0.59 Percent (%) ... III .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 1005 415 590 ... fill ... .. ... Page 33 fill ... ... ... ... .. III Area 34 3rd Floor - Planning (circulation) '" III Specifications: 2'x 4' Drop-Ins I 2 lamp I F40CW/SS - 34 Walls '" Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps. Replace lamps 2 for 2. Clean fixtures, tit '" tit Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve. '" tit '" 11II Fixture I Lamn Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existinl! 11 2 F40CW/SS 78 $1,95 15000 (20000) 0.105 9 2730 '" 11II - tit '" .. - tit Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 245,95 0,00 0.00 52.57 298.52 '" .. ... tit Estimated Annual Cost Savings $53.58 '" .. ... tit Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. .. ... Page 34 III Prooosed 11 2 F032T8-41 ks 64 $2.50 26000 0.105 9 2730 201.80 0.00 0.00 43,14 244.94 0.18 Percent (%) 2342 1922 420 ... - ... ... ... .. Area 35 2nd Floor - City Treasurer '" .. Specifications: 2' x 4' Drop-Ins 14 lamp 1 F40CW/SS - 34 Watts .. .. Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly. ''"" .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, '"" .. "" III Fixture I LamD Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rale Months of Cooling Annual Bum Time (hours) Existing 17 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 '" .. '"" .. '"" .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 760,20 0,00 0,00 162.49 922,69 T ". , .. '"" .. Estimated Annual Cost Savings $473.17 "" .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. r- .. , ... .. Page 35 Prooosed 17 2 F032TB-41 ks 76 $2.50 26000 0.105 9 2730 370.35 0.00 0.00 79.16 449.51 0.51 Percent ('!Ii) 7240 3527 3713 ... .. ... .. ... .. Area 36 2nd Floor - City Treasurer (storage) .. .. Specifications: 4' Fixtures I 2 laillp I F40CWISS - 34 Watts .. Recommendations: Replace fixtures with 2 Surface Wraps, electronic ballasts and F032- 41 OOk lamps I two lamp fixtures, Add One Ultra-Sonic Occupancy Sensor. ... ... .. Anticipated Results: Will increase existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. .. .. .. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 2 2 F40CW/SS 78 $1.95 1 5000 (20000) 0,105 9 2730 .. "" .. ... .. "" .. ... .. Comparitive Cost Light Energy Lamps Labor Cooling Tolal Annual Cost 44.72 0.00 0,00 9,56 54.28 .. .. ... $23.10 .. Estimated Annual Cost Savings ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... .. .. .. .. Page 36 .. ProPOsed 2 2 F032T8-41 ks 64 $2.50 26000 0,105 9 1911 25.68 0.00 0.00 5.49 31,17 0.43 Percent (%) 426 245 181 - - - ... - .. Area 37 2nd Floor - City Treasurer (storage/filing rooms) .. .. Specifications: 2' x 4' Drop-Ins /4 lamp / F40CW/SS - 34 Watts .. . Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures, Add Four Ultra-Sonic Occupancy Sensors. Recommendations: .. .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve, .. .. .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rale Months of Cooling Annual Bum Time (hours) Existing 9 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 .. .. ill .. .. .. . .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 402.46 0.00 0.00 86,03 488.48 . .. . .. . Estimated Annual Cost Savings $321.90 .. . .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. ... .. "" Page 37 .. Prooosed 9 2 F032T8-41 ks 76 $2.50 26000 0.105 9 1911 137.25 0.00 0.00 29,34 166.58 0.66 Percent (%) 3833 1307 2526 "" .. "" III .. III 2nd Floor - City Clerk Area 38 .. III Specifications: 2' x 4' Drop-Ins 14 lamp 1 F40CW/SS - 34 Watts .. Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps;; for 4 and clean fixtures thoroughly. III Ill' .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will also improve. Ill' .. Ill' II Fixture I Lamu Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 76 4 F40CW/SS 156 $1.95 15000 (20000) 0.105 9 2730 "" .. !Ill ill III' II !Ill III Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 3398.52 0.00 0.00 726.43 4124.96 Ill' .. .. Estimated Annual Cost Savings $2,115.36 III .. III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduc.1ion - Annual Kilowatt Hours .. ill "" .. .. .. .. Page 38 .. Prooosed 76 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 1655.69 0.00 0.00 353,90 2009.59 0.51 Percent ('!O) 32367 15768 16598 ... ... - - ... ill Area 39 2nd Floor - City Clerk (storage) .. ... 8' Fixtures I 4 lamp I F40CW/SS - 34 Watts Specifications: .. ... Replace fixtures with 4 Surface Wraps, electronic ballasts and F032- 41 OOk lamps I two lilmp fixtures, Add Two Ultra-Sonic Occupancy Sensors, Recommendations: .. ... Anticipated Results: Will increase existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, .. ... .. . Fixture I Lamn Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 4 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 .. .. .. .. .. .. .. ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 178.87 0,00 0.00 38,23 217,10 ... .. .. .. Estimated Annual Cost Savings $154.76 .. ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. ill "" ill .. Page 39 ... Prooosed 4 2 F032T8-41 ks 64 $2.50 26000 0.105 9 1911 51.37 0.00 0,00 10.98 62.35 0.71 Percent (%) 1704 489 1214 - - - ... .. .. Area 40 2nd Floor - Civil Service '"' .. Specifications: 2' x 4' Drop-Ins i 4 lamp I F40CW/SS - 34 Watts I!IIII Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures thoroughly. 11II ... 11II Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, "" 11II "" . Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months nf Cooling Annual Burn Time (hours) Existing 21 4 F40CW/SS 156 $1,95 15000 (20000) 0.105 9 2730 "" .. ... iiII III" .. .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 939.07 0.00 0,00 200,73 1139.79 III .. III III" liIo Estimated Annual Cost Savings $584.51 III" .. '" III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours III" .. Ii"' .. '" III Page 40 Prooosed 21 2 F032T8-41 ks 76 $2.50 26000 0,105 9 2730 457.49 0.00 0.00 97,79 555.28 0.51 Percent (%) 8943 4357 4586 - - ,- ... ... ... Area 41 2nd Floor - Civil Service (storage) '" ill Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts ... III Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and clean fixtures. Add Two Passive Ultra-Sonic Occupancy Sensors, Recommendations: '" .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will also improve, ... .. ... .. Fixture I Lamn Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 8 4 F40CW/SS 156 $1,95 1 5000 (20000) 0,105 9 2730 ,. .. ... III '" .. ,. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 357.74 0.00 0,00 76.47 434,21 "" .. ... .. Estimated Annual Cost Savings $286.13 "" .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. .. .. .. .. "" Page 41 .. Prooosed 8 2 F032T8-41 ks 76 $2.50 26000 0,105 9 1911 122.00 0.00 0.00 26,08 148.08 0.66 Percent (%) 3407 1162 2245 - .. ... .. ... .. Area 42 Mezzanine - COllncii Offices ... II. Specifications: 4' Surface Wraps I 2 lamp I F40CW/SS - 34 Watts ... II. Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps, Replace lamps 2 for 2, Clean fixtures, , II" II. Anticipated Results: Will exceed existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will improve, II" ill "" . Fixture I Lamp Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existing 3 2 F40CW/SS 78 $1.95 15000 (20000) 0.105 9 2730 II" ill pili .. "" .. "" Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 67,08 0,00 0.00 14,34 81.41 ill .. .. .. lit Estimated Annual Cost Savings $14.61 .. II. , II" II. Estimated Ann~al Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ". .. "" Page 42 .. Provased 3 2 F032T8-41 ks 64 $2,50 26000 0.105 9 2730 55,04 0,00 0,00 11,76 66,80 0.18 Percent (%) 639 ~24 115 ... - - - ... ... Area 43 Mezzanine - Council Offices "'" lilt Specifications: 2' x 4' Surface Boxes 14 lamp 1 F40CW/SS - 34 Watts !II' Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and clean fixtures thoroughly, . "'" lilt Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve, !lI' . .. .. Fixture / Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 6 4 F40CW/SS 156 $1.95 15000 (20000) 0.105 9 2730 "" .. !II' .. "" .. "" Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 268.30 0.00 0.00 57.35 325,65 . .. . ... .. Estimated Annual Cost Savings $167.00 ... .. ... . Estimated Annuai Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (atter completion) Estimated Reduction - Annual Kilowatt Hours ... .. "'" ... ... Page 43 ... Prooosed 6 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 130.71 0,00 0,00 27,94 158.65 0.51 Percent (%) 2555 1245 1310 t t: t: Area 44 Mezzanine - Council Offices t: Specifications: 4 X 4' Surface Box 14 lamp 1 F40CW/SS - 34 Watt t: Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps. Replace lamps 4 for 4. Clean fixture thoroughly, t: Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced. Color rendering will improve, c c Fixture I Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existinl! 1 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 t t c E Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 44.72 0.00 0.00 9,56 54.28 t .. .. Estimated Annual Cost Savings $16.70 r III t Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours t t t Page 44 Prooosed 1 4 F032T8-41 ks 108 $2.50 26000 0,105 9 2730 30.96 0.00 0.00 6.62 37.58 0.31 Percent (%) 426 295 131 - --, - - .... .. Area 46 Mezzanine - Conference ...' .. Specifications: 75 Watt Indoor Flood Lamps (Downlights) "" Recommendations: Replace lamps with 45 Watt HIR Flood Lamps, ... "" .. Anticipated Results: Will equal existing light levels, Lamp life will be about the same. Lamp heat will be reduced, "" ... !It lit Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 2 1 75W Indoor Flood 75 $2.95 2000 0.105 9 2730 !It lit "" .. !II ill "" .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 43.00 0.00 0,00 9.19 52.19 ... .. - ... Estimated Annual Cost Savings $20.88 ... . ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... ... ... "" . ,. ~ Page 46 Prooosed 2 1 45 Watt HIR 45 $7.85 2000 0,105 9 2730 25.80 0.00 0.00 5.51 31.31 0.40 Percent (%) 410 246 164 ... - ... ... .. ... Area 47 1 st Floor - Lobby III ill Specifications: 1'x 4' Surface Box I 2 lamp I F40CW/SS - 34 Watts ... III Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps, Replace lamps 2 for 2. Clean fixtures. III ill Anticipated Results: Will exceed existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will improve. .. ill '" .. Fixture I LamD Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 15 2 F40CW/SS 78 $1,95 15000 (20000) 0,105 9 2730 .. ill ,. .. .. .. III Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 335.38 0.00 0.00 71,69 407.07 .. III .. .. .. Estimated Annual Cost Savings $73.06 .. .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. ... .. ... ... ... Page 47 ... Prooosed 15 2 F032T8-41 ks 64 $2,50 26000 0.105 9 2730 275.18 0,00 0.00 58.82 334,00 0.18 Percent (%) 3194 2621 573 - - ... .. ... ... "" Area 48 1 st Floor - Council Chambers .. Specifications: 1 'x 4' Surface Box I 2 lamp I F40CW/SS - 34 Walls ... ... Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps, Replace lamps 2 for 2. Clean fixtures, ... .. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve, .. 11II !!II 11II Fixture I LamD Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rale Months of Cooling Annual Bum Time (hours) Existing 8 2 F40CW/SS 78 $1.95 15000 (20000) 0.105 9 2730 .. 11II !II .. .. 11II !II 11II Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 178.87 0,00 0.00 38,23 217,10 iio ia - .. Estimated Annual Cost Savings $38.97 .. .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 11II ... .. .... ... .... ... Page 48 Prooosed 8 2 F032T8-41 ks 64 $2.50 26000 0.105 9 2730 146.76 0.00 0.00 31.37 178,14 0.18 Percent (%) 1704 1398 306 .. .. .. .. ,- .. Area 49 1st Floor - Council Chambers .. .. Specifications: 4 X 4' Surface Box I 4 lamp I F40CW/SS - 34 Watt III .. Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps. Replace lamps 4 for 6, Clean fixture thoroughly. III .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced. Color rendering will improve. III .. III .. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rale Months of Cooling Annual Bum Time (hours) Existing 2 6 F40CW/SS 234 $1,95 15000 (20000) 0.105 9 520 III .. III .. ... .. III .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 25.55 0.00 0.00 5.46 31,01 .. .. .. .. Estimated Annual Cost Savings $16.70 III .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours III .. "" ... ... .. ... Page 49 .. Proposed 2 4 F032T8-41 ks 108 $2.50 26000 0.105 9 520 11,79 0,00 0.00 2.52 14.31 0.54 Percent (%) 243 112 131 - .. ... ... ... .. Area 50 1 st Floor - Council Chambers ... '" Specifications: 2' x 2' Drop-Ins - U-tubes I 2 lamp I FB40CW - 40 Watts "'" Recommendations: Retrofit fixtures with electronic ballasts and F017-4100ks Lamps. Replace lamps 2 for 2, Add specular reflectors. (3 fixtures = 22ft. high) iii "'" iii Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve. "'" .. . III ... Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 4 2 FB40CW 92 $5.85 18000 0.105 9 520 PrODOsed 4 2 F017T8-41 ks 38 $3.85 26000 0,105 9 520 ... .. iii . III ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 20,09 0,00 0.00 4.29 24.39 8.30 0.00 0.00 1.77 10.07 .. . lit ... . Estimated Annual Cost Savings $14.31 0.59 Percent (%) "'" . Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 191 79 112 "'" . "" ... ... ... ... ... Page 50 - - """'" - - Area 51 1 st Floor - Council Chambers 1 Audio Visual .. Specifications: 2' x 4' Drop-Ins 14 lamp 1 F40CW/SS - 34 Watts .. .. Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and clean fixtures thoroughly, ... . Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve. .. .. '" . Fixture / Lamo Analysis Fixture Quanlity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existinl! 6 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 .. .. .. . .. .. .. Comparilive Cost Light Energy Lamps Labor Cooling Total Annual Cost 268.30 0,00 0,00 57,35 325.65 . ,. .. "" .. Estimated Annual Cost Savings $167.00 .. . ". .. Estimated A"nual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt HOllrs - .. .. .. ... ... Page 51 PrODOsed 6 2 F032T8-41 ks 76 $2.50 26000 0,105 9 2730 130.71 0.00 0.00 27.94 158.65 0.51 Percent (%) 2555 1245 1310 .... ... .. .. "" .. Area 52 1 st Floor - Council Chambers .. .. Specifications: 2'x 4' Drop-Ins I 2 lamp I F40CW/SS - 34 Watts "" .. Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 2. Clean fixtures, (22 feet high) Remote ballast. .. .. Anticipated Results: Will exceed existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will improve. .. .. .. III Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existing 26 2 F40CW/SS 78 $1,95 15000 (20000) 0,105 9 520 .. .. .. .. .. . .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 110,73 0,00 0.00 23,67 134.40 .. .. .. .. Estimated Annual Cost Savings $41.35 "" .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. "" .. .... ... .. Page 52 .. PrODOsed 26 2 F032T8-41 ks 54 $2.50 26000 0.105 9 520 76.66 0,00 0,00 16,39 93,04 0.31 Percent (%) 1055 730 324 - - - ... .. Area 53 1st Floor - Council Chambers (Wall Washers) "" ... Specifications: 1 'x 4' Wall Washers I 2 lamp I F40CW/SS - 34 Watts .. .. Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps, Replace lamps 2 for 2. Clean fixtures. ... .. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve. .. .. .. II Fixture I Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rale Months of Cooling Annual Bum Time (bours) Existing 10 2 F40CW/SS 78 $1,95 15000 (20000) 0,105 9 2730 "" .. .. .. .. II .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 223.59 0.00 0.00 47.79 271.38 .. ... .. . .. .. Estimated Annual Cost Savings $48.71 .. .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. .. .. ... .. .. Page 53 .. Prowsed 10 2 F032T8-41 ks 64 $2,50 26000 0.105 9 2730 183,46 0.00 0,00 39,21 222.67 0.18 Percent (%) 2129 1747 382 ... - - ... ... ... Area 54 Basement - EOC ... .. Specifications: 2' x 4' Drop-Ins 14 lamp I F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 fer 4 and clean fixtures thoroughly. .. ... .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will also improve. .. .. . ill III Fixture I Lama Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) 4 F40CW/SS 156 $1,95 15000 (20000) 0.105 9 2730 Existing 22 !II III . .. !II . .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 983,78 0.00 0.00 210,28 1194,07 . .. ... .. Estimated Annual Cost Savings $612.34 - .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... .. .. .. ... Page 54 .. Prooosed 22 2 F032T8-41 ks 76 $2.50 26000 0,105 9 2730 479.28 0,00 0.00 102,45 581.72 0.51 Percent (%) 9369 4565 4805 ... .. ..' ... '" ... Area 55 Basement - B57 / Break Room I Mail Room '" ... Specifications: 2' x 4' Drop-Ins / 4 lamp / F40CW/SS - 34 Watts "'" .. Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and clean fixtures thoroughly. !"" ... Anticipated Results: Will equal existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced. Color rendering will also improve, pili .. ,. iii Fixture I LamD Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 8 4 F40CW/SS 156 51.95 15000 (20000) 0,105 9 2730 !"" Ii. !"" Ii. !"" III !"" .. Comparitive Cost Light Energy Lamps Labor Cooling T olal Annual Cost 357,74 0,00 0.00 76.47 434.21 iii' ~ .. "" .. Estimated Annual Cost Savings t222.67 "" .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours "'" III ~ lot ;', ... lot "'" lot Page 55 Prooosed 8 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 174.28 0.00 0.00 37.25 211.54 0.51 Percent (%) 3407 1660 1747 - - - .. - ... Arr.a 56 Basement - Central ServlCG;S ... .. Specifica!ions: 2' x 4' Drop-ins i 4 lamp I F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures wi Ii"! HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and Clean fixtures thoroughly. .. ... .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve, ... .. ... Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 25 4 F40CW/SS 156 $1.95 15000 (20000) 0,105 9 2730 .. ... .. ... .. ... .. ... Comparitive Cost Light Energy Lamps Labor Cooling Toml Annual Cost 1117.94 0.00 0,00 238,96 1356,89 .. ... .. ... .. Estimated Annual Cost Savings $695.&4 ... IiiII Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... ... ... ... ... Page 56 .. Prooosed 25 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 544.64 0.00 0.00 116.42 661.05 0.51 Percent (%) 10647 5187 5460 .. .. .. .. .. .. Area 57 Basement - Central Services 1 Office Rooms ... III Specifications: 2' x 4' Drop-Ins 14 lamp 1 F40CW/SS - 34 Watts ... ... Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and clean fixtures. Add Five Ultra-Sonic Occupancy Sensors, Recommendations: .. III Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. ... ... ... Fixture / Lamp Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 13 4 F40CW/SS 156 $1,95 15000 (20000) 0.105 9 2730 .. ... ... ... .. ... .. ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 5Bl,33 0,00 0.00 124,26 705,5B .. !II' .. ... .. Estimated Annual Cost Savings $464.96 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... ... ... .. .. ... ... Page 57 .. Prooosed 13 2 F032TB-41 ks 76 $2.50 26000 0,105 9 1911 19B.25 0.00 0.00 42.3B 240.62 0.66 Percent (%) 5536 lBBB 3648 .. ... .. ... ... ... Area 58 Basement - Central Services ... III Specifications: 2' x 2' Drop-Ins - U-Iubes I 2 lamp I FB40CW - 40 Watts ... Recommendations: Retrofit fixtures with electronic ballasts and F017-4100ks Lamps. Replace lamps 2 for 2. Add specular reflectors, .. ... III Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve. II" III "" .. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 2 2 FB40CW 92 $5,85 18000 0,105 9 2730 PrODOsed 2 2 FOl7T8-41 ks 38 $3,85 26000 0.105 9 2730 III II" III ill .. ill II" III Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 52,74 0.00 0.00 11,27 64,02 21.79 0.00 0.00 4.66 26.44 "" III "" III Estimated Annual Cost Savings $37.58 0.59 Percent (%) .. III III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after compietion) Estimated Reduction - Annual Kilowatt Hours 502 207 295 .. "" ... "" lit "" Page 58 III ... .. ... .. ... ... Area 59 Basement - MIS 1 Building Management .. ... Specifications: 2' x 4' Drop-Ins 14 lamp 1 F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 lor 4 and dean fixtures thoroughly, ... .. .. Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced. Color rendering will also improve. '"" .. .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 28 4 F40CW/SS 156 $1.95 15000 (20000) 0.105 9 2730 .. .. .. ... ... .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 1252,09 0,00 0.00 267,63 1519.72 .. ... ... .. ... Estimated Annual Cost Savings $779.34 .. ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. ... .. .. ... ... ... Page 59 III PrODOsed 28 2 F032T8-41 ks 76 $2.50 26000 0,105 9 2730 609,99 0,00 0.00 130,39 740.38 0.51 Percent (%) 11925 5809 6115 .. .. .. .. .. .. Area 60 Basement - MIS I Building Management ... IiIII 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts Specifications: ... IiIII Retrofit fixtures with H8F electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 4 and clean fixtures, Add Fifteen Ultra-Sonic Occupancy Sensors. Recommendations: ... ... Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve, ... . .. Fixture I Lamv Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 49 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 ... ... ... ... ... .. ... .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 2191,15 0.00 0.00 468,36 2659.51 IiIII - .. ... ... - Estimated Annual Cost Savings $1,752.55 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... ... ... ... ... IiIII ... Page 60 ... Prooosed 49 2 F032T8-41 ks 76 $2,50 26000 0.105 9 1911 747.24 0,00 0.00 159.72 906.96 0.66 Percent (%) 20868 7117 13752 .. - .. - .. III Area 61 Basement - Building Management .. .. Specifications: 2' x 2' Drop-Ins - U-tubes I 2 lamp J FB40CW - 40 Watts .. Recommendations: Retrofit fixtures with electronic ballasts and F017-41 OOks Lamps, Replace lamps 2 for 2. Add specular reflectors, III .. III Anticipated Results: Will equal existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve. ... III ... III Fixture I Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (bours) Existinl! 8 2 FB40CW 92 $5,85 18000 0,105 9 2730 Prooosed 8 2 F017T8-41 ks 38 $3.85 26000 0.105 9 2730 ill .. .. .. lOll .. '" Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 210.97 0,00 0,00 45,10 256,07 87.14 0.00 0.00 18.63 105.77 .. .. III .. III Estimated Annual Cost Savings $150.30 0.59 Percent (%) '" III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 2009 830 1179 .. .. .. .. ~ ... ... Page 61 ... - - - 1M - - Area 62 Penthouse 1 Mechanical ... - Specifications: 2'x 4' Drop-Ins 12 lamp 1 F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 2. Clean fixtures, Remote ballast. .. ... .. Anticipated Results: Will exceed existing light levels. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will improve. ... .. ... .. Fixture I Laffin Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (bours) Existing 28 2 F40CW/SS 78 $1.95 15000 (20000) 0,105 9 780 ... .. .. .. ... .. ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 178,87 0,00 0,00 38,23 217.10 .. ... .. "" .. Estimated Annual Cost Savings $66.80 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... till ... lOll ... .. ... Page 62 lOll Prooosed 28 2 F032T8-41 ks 54 $2.50 26000 0.105 9 780 123.83 0.00 0.00 26.47 150.30 0.31 Percent (%) 1704 1179 524 - - - ... - .. Area 63 Penthouse I Mechanical ... .. Specifications: 8' Industrial Hoods I 4 lamp I F40CW/SS - 34 Watt ... Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps. Replace lamps 4 for 4, Clean fixture thoroughly, .. ... .. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced. Color rendering will improve, .. .. .. Fixture I Laffin Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existin I! 13 4 F40CW/SS 156 $1.95 15000 (20000) 0.105 9 780 .. .. .. ... .. .. .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 166,09 0.00 0,00 35,50 201,60 .. .. ... .. Estimated Annual Cost Savings $62.03 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... .. ... loll ... Page 63 .. Prooosed 13 4 F032T8-41 ks 108 $2.50 26000 0,105 9 780 114.99 0.00 0.00 24,58 139.57 0.31 Percent (%) 1582 1095 487 - - - - - ... Area 64 Stairwells ... ... Specifications: 4' Strips 11 lamp 1 F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps. Replace lamps 1 for 1, - ... - Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly. Ballast heat will be greatly reduced, ... - ... Fixture I LamD Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 54 1 F40CW/SS 48 $1,95 15000 (20000) 0,105 o 8760 .. .. .. "" .. ... III "" Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 2384,12 0,00 0.00 0,00 2384,12 III ... .. - .. Estimated Annual Cost Savings $695.37 ... .. ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... ... .. - .. ... Page 64 .. Prooosed 54 1 F032T8-41 ks 34 $2.50 26000 0.105 o 8760 1688.75 0,00 0,00 0.00 1688.75 0.29 Perceot (%) 22706 16083 6623 - - - - ... - Area 65 Common - Elevators ... .. Specifications: 4' Strips 11 lamp 1 F40CW/SS - 34 Watts ... .. Recommendations: Retrofit fixtures with electronic ballasts and F032-4100ks Lamps, Replace lamps 1 for 1. ... .. Anticipated Results: Will exceed existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, ... .. .. .. Fixture / Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 6 1 F40CW/SS 48 $1.95 15000 (20000) 0,105 o 8760 ill ... .. ... ill ... ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 264,90 0,00 0,00 0,00 264,90 .. ... .. ... .. Estimated Annual Cost Savings ~7.26 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... .. ... ... ... Page 65 .. Proposed 6 1 F032T8-41 ks 34 $2,50 26000 0,105 o 8760 187,64 0.00 0,00 0.00 187.64 0.29 Percent (%) 2523 1787 736 - - - - - - Area 66 Common - Circulation .. ... Specifications: 8' Surface Wraps I 2 lamp I F40CW/SS - 34 Watts - .. Recommendations: Retrofit fixtures with LBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 2, Clean fixtures, Remote ballast. .. .. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will improve. - .. .. lIII .. Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 179 2 F40CW/SS 78 $1.95 15000 (20000) 0,105 9 2730 .. .. ... .. "" .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 4002.21 0.00 0,00 855.47 4857.68 .. . .. .. ... .. Estimated Annual Cost Savings $1,868.34 .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. - .. - ... ... .. Page 66 ... PrODOSed 179 2 F032T8-41 ks 48 $2.50 26000 0.105 9 2730 2462.90 0.00 0.00 526.44 2989.34 0.38 Percent (%) 38116 23456 14660 - - - - ... .. Area 67 Common - Circulation ... .. Specifications: 4' Strips /1 lamp! F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with electronic ballasts and F032-41 OOks Lamps. Replace lamps 1 for 1, Use remote ballast. .. .. .. Anticipated Results: Will exceed existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced. .. .. ... .. Fixture I Laffin Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Walts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 14 1 F40CW/SS 48 $1.95 15000 (20000) 0.105 9 2730 .. ... .. ... .. ... ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 192.63 0.00 0.00 41.17 233,80 .. .. .. ... .. Estimated Annual Cost Savings $102.29 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... .. ... .. ... Page 67 .... Prooosed 14 1 F032T8-41 ks 27 $2.50 26000 0,105 9 2730 108,35 0.00 0.00 23.16 131.51 0.44 Percent (%) 1835 1032 803 - .. .. .. ... .. Area 68 Common - Circulation .. .. Specifications: 3' Strips 11 lamp 1 F40CW/SS - 34 Watts .. .. Recommendations: Retrofit fixtures with electronic ballasts and F025-4100ks Lamps. Replace lamps 1 for 1, Use remote ballast. 1 ... .. Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, ... .. ... Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watls (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existine 15 1 F36CW 45 $1.95 15000 (20000) 0.105 9 2730 .. ... .. - .. .. .. ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 193.49 0,00 0,00 41,36 234,85 .. .. .. ... .. Estimated Annual Cost Savings $93.94 ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... ... ... ... ... Page 68 ... Prooosed 15 1 F025T8-41 ks 27 $2.50 26000 0,105 9 2730 116.09 0,00 0,00 24,81 140,91 0.40 Percent (%) 1843 1106 737 - - .. .. - .. Area 69 Common - ElectricHI Rooms ... III Specifications: 8' Industrial Hoods 12 lamp I F40CW/SS - 34 Watts ... Recommendations: Retrofit fixtures with LBF electronic ballasts and F032-4100ks Lamps. Replace lamps 2 for 2, Clean fixtures, III ... III Anticipated Results: Will exceed existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will improve, ... III .. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 15 2 F40CW/SS 78 $1.95 1 5000 (20000) 0,105 9 520 III .. III ... .. ... III '" .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 63,88 0,00 0,00 13,65 77,54 .. ... ... 11II Estimated Annual Cost Savings $29.82 ... 11II ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 11II ... ... ... ... ... Page 69 .. PrODOsed 15 2 F032T8-41 ks 48 $2,50 26000 0.105 9 520 39.31 0,00 0,00 8.40 47,71 0.38 Percent (%) 608 374 234 ... - ~ .. ... ... Area 70 Common - Ditto Rooms I Storage ... .. Specifications: 4' Surfaces Wraps I 4 lamp I F40CW/SS - 34 Watts "" Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 and clean fixtures thoroughly. .. "" .. Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve, ... III "'" ill Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existing 7 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 .. III "" .. "" III "" III Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 313.02 0.00 0,00 66,91 379.93 "'" III .. III Estimated Annual Cost Savings $194.84 ... .. ... Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. ... .. ... .. ... Page 70 ... Prooosed 7 2 F032T8-41 ks 76 $2.50 26000 0.105 9 2730 152.50 0.00 0,00 32.60 185,09 0.51 Percent (%) 2981 1452 1529 - - - ... - ... Area 71 Common - Restrooms ... ... Specifications: l' x 4' Drop-Ins 12 lamp I F40CW/SS - 34 Watts ". .. Retrofit fixtures with electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 2 & clean fixture. Add Fourteen Ultra-Sonic Occupancy Sensors. Use remote ballast 66%. Recommendations: .. .. Anticipated Results: Will increase existing light levels, Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve. .. .. .. Fixture I Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (hours) Existinl! 57 2 F40CW/SS 78 $1.95 15000 (20000) 0.105 9 2730 .. .. .. .. .. .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 1274.45 0,00 0.00 272.41 1546.86 .. ... .. .. .. Estimated Annual Cost Savings $713.93 .. .. .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. ... ... .. ... ". .. Page 71 Proposed 57 2 F032T8-41 ks 60 Avg, $2.50 26000 0.105 9 1911 686.24 0.00 0.00 146.68 832.92 0.46 Percent (%) 12138 6536 5602 - - - - .' .. Area 72 Common - Restrooms I Janitoria! ... ... Specifications: 2' x 2' Drop-Ins - 2' tubes I 2 lamp I F24CW - 40 Watts ... Recommendations: Retrofit fixtures with electronic ballasts and F017-4100ks Lamps, Replace lamps 2 for 2. .. ... ... Anticipated Results: Will equal existing light levels. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will improve, ... .. ... ... Fixture / Lamp Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (bours) Existing 14 2 F24CW 90 $5,85 18000 0.105 9 2730 Proposed 14 2 FOl7T8-41 ks 38 $3,85 26000 0,105 9 2730 III .. .. ,.. .. .. ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 361.18 0.00 0.00 77.20 438,38 152.50 0.00 0.00 32.60 185,09 ... III iii "" .. Estimated Annual Cost Savings $253.29 0.58 Percent (%) "" .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 3440 1452 1987 ... ... ... .. ... .. ... Page 72 .. - - - .. .. .. Area 73 Common - Elevators .. ill Specifications: 2' Strips - 2' tubes I 2 lamp I F24CW - 40 Walts ... Recommendations: Remove fixtures, ill ... ill Anticipated Results: Will equal existing light levels, Lamp life will increase significantly. BaJlast heat will be greatly reduced, Color rendering will improve. .. .. .. .. Fixture I LamD Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 9 2 F24CW 90 $5.85 18000 0,105 9 2730 PrODOsed o 2 F017T8-41ks 38 $3.85 26000 0,105 9 2730 ill .. .. ,. ill .. , Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 232.19 0.00 0.00 49,63 281.82 0.00 0.00 0.00 0,00 0.00 ,. .. ,. .. ... .. Estimated Annual Cost Savings $281.82 1.00 Percent (%) ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 2211 Q 2211 ... .. - .. - ... I ... Page 73 ... - - ... - ... - Area 74 Common - Exit Signs ... - Specifications: 15 Watt T -6 Lamps in Exit Signs, ... Recommendations: Retrofit with 7 Watt P,L. 's Replace lamps 1 for 2, - ... III Anticipated Results: Will equal existing light levels, Lamp life will increase approximately 1200%. Lamp heat will be significantly reduced, ... - ... III Fixture I Lamo Analvsis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 40 2 15 Watt Incand, 30 $0,95 750 0,105 9 8760 PrODOsed 40 1 ... .. ... 7 Watt P,L. III ... III 9 $2.95 10000 0.105 9 8760 ... Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 1103.76 0.00 0.00 235.93 1339.69 331.13 0.00 0,00 70.78 401.91 III ... .. ... .. Estimated Annual Cost Savings $937.78 0.70 Percent (%) ... III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours 10512 3154 7358 ... iIt ... loot ;JIIIl ... ... Page 74 ... - - - - ... - Area 75 Opt. 1 Mezzanine through 6th Floor - Daylight Dimming ... .. Specifications: 2' x 4' Drop-Ins 14 lamp 1 F40CW/SS - 34 Watts .. Retrofit fixtures with dimming electronic ballasts and F032-4100ks Lamps, Replace lamps 2 for 4 & clean fixture, Replace all acrylic diffusers. Add 119 Ambient Light Sensors for continuous light adjustment. ... Recommendations: .. .. Anticipated Results: Will maintain 40-50+ FC at tasks. Lamp life will increase significantly, Ballast heat will be greatly reduced, Color rendering will also improve. ... .. .. Fixture I LaffiO Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt hours) Kilowatt Hour Rate Months of Cooling Annual Burn Time (hours) Existing 343 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 .. .. .. .. .. .. .. .. .. Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 15338,07 0,00 0,00 3278,51 18616.58 .. .. .. Estimated Annual Cost Savings $14,559.12 .. ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours ... .. ... - .... .. ... Page 75 .. Prooosed 343 2 F032T8-41 ks 34 (averag $2.50 26000 0,105 9 2730 3342.91 0.00 0,00 714,55 4057.46 0.78 Percent (%) 146077 31837 114240 ... ... ... ... ... lot Area 75 Opt. 2 Mezzanine through 6th Floor - IR Occ. Sensing I Daylight Control ... lot Specifications: 2' x 4' Drop-Ins I 4 lamp I F40CW/SS - 34 Watts .. Recommendations: Retrofit fixtures with HBF electronic ballasts and F032-41 OOks Lamps. lot Replace lamps 2 for 4 & clean fixture, Replace all acrylic diffusers. Add 119 IR Occupancy Sensors with Daylight Override. Remote Ballast 50% ... III Anticipated Results: Will maintain 40-50+ FC at tasks. Lamp life will increase significantly. Ballast heat will be greatly reduced, Color rendering will also improve. ... III .. Fixture I Lamo Analysis Fixture Quantity Lamps Per Fixture Lamp Type Lamp Watts (per fixture) Lamp Cost Lamp Life (kilowatt bours) Kilowatt Hour Rate Months of Cooling Annual Bum Time (bours) Existin!! 343 4 F40CW/SS 156 $1,95 15000 (20000) 0,105 9 2730 III .. III .. III ... III '" III Comparitive Cost Light Energy Lamps Labor Cooling Total Annual Cost 15338.07 0.00 0,00 3278,51 18616.58 .. l01I . . .. III Estimated Annual Cost Savings $13,174.81 ... III Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Estimated Reduction - Annual Kilowatt Hours .. III ... l01I .. III .. Page 76 l01I Prooosed 343 2 F032T8-41 ks 76 $2.50 26000 0.105 9 1638 4483,44 0.00 0.00 958,33 5441,77 0.71 Percent (%) 146077 42699 103377 - - OPTION 1 - CONTINUOUS DIMMING & ALS - ... .... Estimated Cumulative Cost Savings .. .. Energy Lamps Labor Cooling 1st Year 37241.43 2055,52 5299.55 7795.21 52391. 71 2nd Year 75227.69 4234,37 10917,07 15746,32 106125.46 3rd Year 113593.81 6478.59 16703.12 23776,95 160552,47 .... .. .. .. .. Energy Lamps Labor Cooling 4th Year 152343.59 8790.13 22662,75 31887,88 215684.36 5th Year 191480.87 11171,02 28801.17 40079.92 ...............,-,.,...,.,..-.-.... ........27...1..5....32........9..9...'..'. . . -- " .. ..... , . . ... ........ ... '.. {:~:~::::'..::..:{.::::;.::;.:<.;.:.)::...,.. , .,:=:::: .. .. ,. .. ASSUMPTIONS & NOTES .. .. ... The above forecast as well as other data contained herein is based on the following assumptions; .. .. (1) Wattage is calculated on a "per fixture basis" in accordance with the equipment manufacturers' specifications and/or ANSI standards, .. .. .. (2) Kilowatt hour rates are calculated using a standing average, This average is subject to variances depending on "KW Demand" and demand cycles in the service area of the respective utility. .. (3) The various "project areas" reflect only estimated lighting energy costs/savings and associated cooling costs savings. Cooling costs savings and incremental heating cost increases associated with light energy reductions are calculated using an ASH RAE net space conditioning savings formula. (Light Energy Savings/Monthly Correction Factor" .35) .. .. .. .. .. (4) The "summary" pages reflect lighting energy, cooling energy related to lighting. lamp and labor cost variances. This includes inflation factors of one percent (1.0%) annually for the purpose of calculating energy costs, Inflation factors for lamps and labor are calculated at three percent (3.0%) annually, ... .. (5) Labor is calculated at 20 minutes per lamp installation (average) multiplied by a $10.00 hourly rate. .... .. (6) Cooling is not factored in the analysis for outside areas, .... .. ... .. - -. OPTION 1 - CONTINUOUS DIMMING & ALS - ASSUMPTIONS & NOTES (con't.) ... .. ... (7) For the purpose of estimating energy rebates, applicable programs from the respective utility company(s) are utilized, In some cases the utility mayor may not calculate cooling load reductions for the purpose of estimating rebates, The respective energy services representative from the utility company will verify and substantiate the information contained herein. ... ... - ... - Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Projected Estimated Annual Kilowatt Hours Saved Kilowatt Hours Reduced (Controls) Estimated Monthly KW Demand Reductions 616585 261905 354680 43587 103.79 42% 58% ... ... .. ... Total Project Cost Estimated Utility Rebate (KW Reduced) Other Controls $147,855.72 $10,379.00 $1,307.61 ... - Total Less Estimated Rebate $136,169.11 .. First Year Estimated Return On Investment (ROI) Estimated Recapture Period (months) ... 31.2 ... NOTE: This evaluation does not take into account additional cost savings attributed to depreciation. ... ... The total project costs are binding. however, any added variance in actual materials and/or labor may affect these costs, Total savings estimates include labor, materials and energy. ... .. Sales tax will be added to the invoice at the current applicable rate. - .. All labor and materials are guaranteed as specified, All work will be completed in a timely and professional manner and in accordance with acceptable practices. Any alterations, changes or modifications in the above specifications will be approved oniy in writing and added to the above estimate, Customer agrees to pay a charge equal to one and one-half percent (1.5%) per month on all past due balances of any invoices in order to reimburse Energy Controls & Concepts for its estimated administrative costs and other losses which may be associated with such delinquint accounts. Notwithstanding, nothing contained herein shall be construed as an alternative performance provision except as provided for in writing, All balances are otherwise due within ten (10) working days from the date of completion of all work specified. ... ... ... ... ... .. ... There will be an additional charge (based on a "per drum" basis at current disposal rates) for proper and legal disposal of magnetic ballasts containing PCB's, There will be an additional charge (based on $,10 per lineal foot) for proper and legal disposal andlor recycling of fluorescent lamps. .. ... .. - ... - - OPTION 1 - CONTINUOUS DIMMING & ALS - - Green Lights I Environmental Impact .. - ... The Environmental Protection Agency (EPA) has taken a strong look at the positive environmental impact of "demand side management", In particular, the EPA estimates that for each kilowatt hour of energy saved there is an associated reduction in generation side pollution, - - .. ... The EPA has recently undertaken the task of retrofitting their own facilities in Washington D.C, with newer triphosphors lamps, specular reflectors and electronic ballasts, This newer technology has proven to result in tremendous savings with an even greater enhancement to the quality of light in all environments, .. ... .. One very significant effect of an energy efficient lighting retrofit is that of emmission reductions. Outlined below is an estimate of your annual reduction of carbon dioxides, sulfur dioxides and nitrogin oxides emitted from the generation of electric power based on national statistics, ... .. ... .. Estimated Annual Carbon Dioxide Reductions (lbs.) 567488 ... Estimated Annual Sulfur Dioxide Reductions (lbs.) 4150 .. ... Estimated Annual Nitrogen Oxide Reductions (lbs.) 2188 .. ... For more information on the environmental affects of demand side management, please contact us or the EPA or talk to us regarding the "Green Lights Partner Program". .. " ... - ... .. .. - .. ... .. - .. - - .. - '.. OPTION 2 - IR OCCUPANCY SENSORS & DAYLIGHT OVERRIDE - ... Estimated Cumulative Cost Savings - .. .. Energy Lamps Labor Cooling 1st Year 36100.91 2127.55 5394.63 7551.42 51174.51 2nd Year 72923.84 4382.75 11112.94 15253.87 103673.40 3rd Year 110115.00 6705.61 17002.79 23033.34 156856.74 .. .. .. - - Energy Lamps Labor Cooling 4th Year 147678.06 9098.16 23069.35 30890.61 210736.18 5th Year 185616.76 11562.48 29317.90 38826.45 I/2. 6. 5. 3. 2.'.3:5. 9.I.: ..............,............. ......................w............w........,...... .. .. - ... - ASSUMPTIONS & NOTES .. - The above forecast as well as other data contained herein is based on the following assumptions; .. - (1) Wattage is calculated on a "per fixture basis" in accordance with the equipment manufacturers' specifications and/or ANSI standards. .. - (2) Kilowatt hour rates are calculated using a standing average. This average is subject to variances depending on "KW Demand" and demand cycles in the service area of the respective utility. .. .. (3) The various "project areas" reflect only estimated lighting energy costs/savings and associated cooling costs savings. Cooling costs savings and incremental heating cost increases associated with light energy reductions are calculated using an ASH RAE net space conditioning savings formula. (Light Energy Savings/Monthly Correction Factor" .35) .. - .. - (4) The "summary" pages reflect lighting energy, cooling energy related to lighting, lamp and labor cost variances. This includes inflation factors of one percent (1.0%) annually for the purpose of calculating energy costs. Inflation factors for lamps and labor are calculated at three percent (3.0%) annually. .. - .. (5) Labor is calculated at 20 minutes per lamp installation (average) multiplied by a $10.00 hourly rate. - ... (6) Cooling is not factored in the analysis for outside areas. - .. - .. ... .. OPTION 2 - IR OCCUPANCY SENSORS & DAYLIGHT OVERRIDE ... .. ASSUMPTIONS & NOTES (con'!.) ... .. (7) For the purpose of estimating energy rebates. applicable programs from the respective utility company(s) are utilized. In some cases the utility mayor may not calculate cooling load reductions for the purpose of estimating rebates. The respective energy services representative from the utility company will verify and substantiate the information contained herein. .. .. ... .. Estimated Annual Kilowatt Usage (existing) Estimated Annual Kilowatt Usage (after completion) Projected Estimated Annual Kilowatt Hours Saved Kilowatt Hours Reduced (Controls) Estimated Monthly KW Demand Reductions 616585 272767 343818 40216 110.31 44% 56% ... .. ... .. ... Total Project Cost Estimated Utility Rebate (KW Reduced) Other Controls $131,406.60 $11 ,031.00 $1,206.48 .. ... Total Less Estimated Rebate $119,169.12 ... First Year Estimated Return On Investment (ROI) Estimated Recapture Period (months) ... 27.9 .. NOTE: This evaluation does not take inlD account additional cost savings attributed to depreciation. ... .. The total project costs are binding, however, any added variance in actual materials and/or labor may affect these costs. Total savings estimates include labor, materials and energy. ... .. Sales tax will be added to the invoice at the current applicable rate. ... .. All labor and materials are guaranteed as specified, All work will be completed in a timely and professional manner and in accordance with acceptable practices. Any alterations, changes or modifications in the above specifications will be approved only in writing and added to the above estimate. Customer agrees to pay a charge equal to one and one-half percent (1.5%) per month on all past due balances of any invoices in order to reimburse Energy Controls & Concepts for its estimated administrative costs and other losses which may be associated with such deiinquint accounts. Notwithstanding, nothing contained herein shall be construed as an alternative performance provision except as provided for in writing. All balances are otherwise due within ten (10) working days from the date of completion of all work specified. ... .. ... .. ... .. ... There will be an additional charge (based on a "per drum" basis at current disposal rates) for proper and legal disposal of magnetic ballasts containing PCB's. There will be an additional charge (based on S.l 0 per lineal foot) for proper and legal disposal and/or recycling of fluorescent lamps. .. ... .. ... .. ... ... OPTION 2 -IR OCCUPANCY SENSORS & DAYLIGHT OVERRIDE ... .. Green Lights I Environmental Impact ... .. .. The Environmental Protection Agency (EPA) has taken a strong look at the positive environmental impact of "demand side management". In particular, the EPA estimates that for each kilowatt hour of energy saved there is an assoCiated reduction in generation side pollution. ... ... III ... The EPA has recently undertaken the task of retrofitting their own facilities in Washington D.C. with newer triphosphors lamps, specular reflectors and electronic ballasts. This newer technology has proven to result in tremendous savings with an even greater enhancement to the quality of light in all environments. III ... .. One very significant effect of an energy efficient lighting retrofit is that of emmission reductions. Outlined below is an estimate of your annual reduction of carbon dioxides, sulfur dioxides and nitrogin oxides emitted from the generation of electric power based on national statistics. III III ... III Estimated Annual Carbon Dioxide Reductions (Ibs.) 550109 ... Estimated Annual Sulfur Dioxide Reductions (Ibs.) 4023 .. ... Estimated Annual Nitrogen Oxide Reductions (Ibs.) 2121 .. ... For more information on the environmental affects of demand side management, please contact us or the EPA or talk to us regarding the "Green Lights Partner Program". III ... .. ... .. ... .. ... .. ... .. ... .. ... ..