HomeMy WebLinkAbout20-City Administrator
CITY OF SAN BERNi lDINO - REQUEST F( .1 COUNCIL ACTION
From:
Fred Wilson, Assistant City
Administrator
Administrative
Subject:
Resolution authorizing agreement
with Motorola, Inc. for the
purchase of an 800 MHz trunked
radio communications system.
D~pt:
Date: November 19, 1993
Synopsis of Previous Council action:
July 1990 -- Mayor and Council authorized the City Administrator to prepare a plan for the purchase and
installation of the 800 MHz System for the City.
August 1990 --
Action Plan represented to Council and was approved.
August 1992 --
Agreement approved with Motorola for the purchase of a M.D.T. System for the City.
October 1992 --
Agreement approved with Omnicon to provide consulting services for the implementation
of the City's 800 MHz Trunked Radio System.
June 1993 --
Motorola awarded purchase order for 800 portable 800 MHz radios.
Recommended motion:
Adopt resolution.
Signature
Contact person: Fred Wilson, Asst. City Administratorphone: 5122
Supporting data attached:
yes
Ward:
FUNDING REQUIREMENTS:
Amount: $1,536,398.36
Source: (Acct. No.) 001-092-55500
(Acct. DescriPtion)
Finance: ~~tUc:::.. /A.,~
/
Council Notes:
,c,.n?fi2
Agenda Item No. 2.0
CITY OF SAN BERNA. .DINO - REQUEST F( 1 COUNCIL ACTION
STAFF REPORT
Overview
The City has been pursuing the acquisition and start up of an 800 MHz radio system for the City for
the past three years. The need for the system was documented in earlier reports and is primarily based
on the inability of the current communication system to accommodate existing and future growth. This
agenda item addresses the proposed implementation plan for the transition of the Police and Fire
Departments to the 800 MHz radio system. The transition plan for this project consists of two phases
as follows:
1.
(a)
Purchase, programming and installation of mobile and portable radios for the
police and fire departments.
(b) The design and cutover of the police and fire dispatch facility to 800 MHz.
2. The purchase of radio system backbone (transmission towers etc.); or, if interference
testing does not identify 'clear' frequencies, the City will contract with the County to
operate as a user on the County 800 MHz radio system.
The cost for the first phase of this project with Motorola is $1,486,398.36.
The cost for the second phase is estimated at approximately $950,000 if the City purchases the radio
system backbone. If the City contracts with the County, the annual costs to operate as a user on the
County system will be approximately $168,000.
Back2I"ound
In the three years preceding August 1990, the County of San Bernardino and the cities had been
dealing with the issue of purchasing and installing an 800 MHz radio communication system. The
County acted as the lead agency on this project and proceeded with the purchase and construction of
a county-wide 800 MHz system. In July 1990, the County requested all cities to make a decision
relative to participating with the County or developing other alternatives. Based on a cost analysis
performed at that time, it was apparent that the establishment and implementation of a city-owned 800
MHz system would be more cost effective than participating in a County system.
Formal action was taken by the Mayor and Council in July 1990 in terms of directing the City
Administrator to prepare an action plan for the start-up of a city-owned 800 MHz system. This action
plan was developed and submitted to the Mayor and Council in August 1990 which recommended that
a two-phase process be implemented. The first phase was a purchase of mobile data terminals (MDT)
system in order to achieve immediate savings in radio air-time usage with the second phase involving
the actual development of the 800 MHz voice system.
The contract for purchase of the MDT system was awarded in March 1992 and the project was
completed in June 1993. The communication engineering work on the 800 MHz project began shortly
after this date and is now completed for this phase of the project.
5.0264
Need for 800 MHz Radio
The need for this system is based on the following issues:
1. A directive from the Federal Communications Commission (FCC) referred to as the
"Refarming of the Radio Spectrum" which, in effect, forces public agencies to replace
the existing 450 MHz frequencies and equipment with the 800 MHz frequencies and
equipment by 1996.
2. Every law enforcement and fire agency in San Bernardino County is currently on the
800 MHz system with the exception of the City of San Bernardino. Allowing the
Police and Fire Departments to move to 800 MHz will allow for significantly improved
communications between these agencies during disasters and other mutual aid
occurrences.
The only means of current mutual aid communications is the state provided VHF
mutual aid radio frequencies. Under this system, for other agencies to talk to us, they
must "patch" a radio to this channel. This delays responses and makes communications
difficult.
3. The existing radio communications network of the police department which consists of
three VHF radio channels is massively overloaded. Industry standards recommend that
a police radio channel never be loaded above 40 percent use. Two of the three
channels are regularly loaded at or above 90 percent use.
4. The VHF spectrum system, which the City implemented more than 20 years ago, is
obsolete. Voice transmissions are often unclear, and the existing system cannot manage
group communications.
5. Improved radio coverage. A Police Officer on the west side of the city, using a
portable radio, can not hear a Police Officer who is on the east side of town. Only one
person can be heard by the dispatcher at a time. When 2 people transmit at the same
time, both are currently blocked out.
The Police Department has documented incidents where a Police Officer has literally
screamed for help on his/her portable radio and their emergency transmission were
"covered" by someone who could not hear the emergency transmission. This is one of
the worst safety problems facing our Police personnel. This problem will be alleviated
since radio transmissions will be repeated and broadcast with enough signal strength
that everyone with a portable radio can hear anyone else with a portable radio anywhere
in our city.
6. Immediate addition of more operational channels for radio traffic. The Police
Department will immediately separate its current 2 channel operations into 6 "talk
groups." Dispatchers will be able to listen to multiple talk groups if necessary with
much more ease than listening to several single user frequencies.
7. Each of the new 800 MHz radios have a red emergency button that can be used to
instantly signal a request for immediate help.
ImDlementation Plan
The City has already purchased new portable radios for police and fire services on the 800 MHz
frequencies. A Statement of Work (Exhibit "A") has been drafted that describes the City's transition
to 800 MHz as a three phase process:
1. The first phase involves the testing of the candidate frequencies, the purchase of the
mobile radio and installations, and the specification and design of the police/fire
dispatch console/backroom equipment.
2. The second phase involves the procurement and implementation of the dispatch centers
and integration of the radio backbone.
3. If the testing of the frequencies realize a set of usable frequencies, the city will
purchase the constructed radio system as the third phase of the project; otherwise, the
City will contract for use on the County system.
It should be noted that the testing of these frequencies is necessary because of the period of time that
has elapsed between the original licensing of the radio channels by the County and the proposed
construction of eight of those frequencies by the City. The original testing of these frequencies
occurred more than four years ago. Since that time there has been activity by commercial and private
companies to try to license these frequencies, and adjacent frequencies, for their own use. If these
parties can show that there is no activity of any of these frequencies, they may petition the FCC to
have the frequency licensed for their use.
As such, it is imperative that the frequencies that the City proposes to use are adequately tested.
Without the test, it would be risky to purchase the radio system backbone since the City would not
have any assurance that the frequencies would be interference-free. If they are not interference-free
they would be substandard for public safety uses.
A joint effort between the City, the County of San Bernardino 800 MHz Group, and Motorola resulted
in a combined and cooperative program to test and secure a final set of radio frequencies that could
be used to successfully construct a new city-owned 800 MHz radio system.
The County of San Bernardino 800 MHz Group has agreed to construct a ten channel 800 MHz
trunking radio system at the Little Sunset radio site for the purpose of comprehensively testing the
City's proposed new radio channels. This testing is being partially underwritten by Motorola, and will
be administered by a team that will include members of the City, County, and Motorola.
If the tested frequencies are determined to be free from interference and useable for the City of San
Bernardino 800 MHz system, the ten-channel trunking system will be released to the City for their use
after a final purchase agreement between the City and Motorola has been secured. If, instead, the
frequencies are impacted by interference, the City will contract for services as a user on the County
800 MHz radio system.
This is a unique opportunity to construct and inspect, prior to purchasing a radio backbone
infrastructure.
Motorola and the County will be investing a substantial amount of money and time in order to test
these frequencies for City use.
It is anticipated that the testing will be completed by February 1994. If the testing indicates that the
ten "clear" channels exist a recommendation will be made to the Council to proceed with purchase of
the radio system backbone at an estimated cost of approximately $900,000. If "clear" channels are
not found the City will be forced to contract with the County as a system user on a permanent basis
at an annual cost of approximately $168,000 a year.
It is anticipated that the Dispatch Center improvements will be completed by March 1994 and that the
system will be fully operational by June 1994.
It should also be noted that all other local government radio users (i.e., Street Department, Refuse
Department, etc.) will also have to migrate to 800 MHz. A phased implementation plan will be
developed through the annual budget process to ensure that this transition occurs by 1996.
Cost
The cost for this phase of the 800 MHz system is broken out as follows:
Police/Fire Mobile Radio Equipment
$ 846,047.48
Dispatch Equipment
$ 640.350.88
TOTAL
$1,486,398.36
Renovation to Radio Equipment Room
$ 35,000
Programming of Radios
$ 15.000
GRAND TOTAL
$1,536,398.36
An accompanying agenda item recommends a financing plan through Motorola. The FY 93-94 budget
includes $354,800 to fund the first year costs associated with this system.
C I T Y 0 F SAN B ERN A R DIN 0
INTEROFFICE MEMORANDUM
TO:
Mayor and Common Council
FROM:
Dennis A. Barlow, Sr. Asst. City Attorney
DATE:
November 30, 1993
RE:
Agreement with Motorola, Inc. for the Purchase
of an 800 MHZ Trunked Radio Communications System
In our review of the Agreement with this Agenda item we felt that
it was important to bring an aspect of the Agreement to your
attention.
Article 23 (page 41) of the Agreement limits Motorola's liability
to the price of the product. It has always been our position that
in such agreements the vendor should be fully responsible for its
actions rather than pushing the liability off on the City. However
we are also aware that in many such cases if the City does not
agree to such a provision there is no agreement at all.
~)
DAB/js [Motorola.Hem]
1 RESOLUTION NO.
2 RESOLUTION OF THE CITY OF SAN BERNARDINO AUTHORIZING AN
AGREEMENT WITH MOTOROLA, INC. FOR THE PURCHASE OF AN 800 MHZ
3 TRUNKED RADIO COMMUNICATIONS SYSTEM INCLUDING DISPATCH EQUIPMENT
AND PORTABLE RADIOS.
4
BE IT RESOLVED BY THE MAYOR AND COMMON COUNCIL OF THE CITY OF
5 SAN BERNARDINO AS FOLLOWS:
6 SECTION 1. The Mayor is hereby authorized and directed to
7 execute on behalf of the City an agreement by and between the City
8 of San Bernardino and Motorola, Inc., for the purchase of an 800
9 MHz trunked radio communication system and equipment including
10 dispatch equipment and portable radios.
11 SECTION 2. The authorization to execute the above referenced
12 agreement is rescinded if the parties to the agreement fail to
13 execute it within sixty (60) days of the passage of this
14 resolution.
15 I HEREBY CERTIFY that the foregoing resolution was duly
16 adopted by the Mayor and Common Council of the city of San
17 Bernardino at a meeting thereof, held on the day
18 of , 1993, by the following vote, to wit:
19
20 Councilmembers AYES NAYS ABSTAIN ABSENT
21 NEGRETE
22 CURLIN
23 HERNANDEZ
24 OBERHELMAN
25 DEVLIN
26 POPE-LUDLAM
27 MILLER
28
RESOLUTION OF 'HE CITY OF SAN BERNARDINO DTHORIZING AN AGREEMEN
WITH MOTOROLA, INC. FOR THE PURCHASE OF ,,,' 800 MHz TRUNKED
RADIO COMMUNICATIONS SYSTEM INCLUDING DISPATCH EQUIPMENT
AND PORTABLE RADIOS.
1
2
3
4
5
6
7
8
City Clerk
The foregoing resolution is hereby approved this
day of
, 1993.
Tom Minor, Mayor
City of San Bernardino
JAMES F. PENMAN
city A torney
.f~
By:
15
16
17
18
19
20
21
22
23
24
25
26
27
28
2
~~ ~~ Cbft
AGREEMENT BETWEEN THE CITY OF SAN BERNARDINO. CALIFORNIA
AND
MOTOROLA COMMUNICATIONS AND ElECTRONICS. INC.
FOR THE
DESIGN. IMPLEMENTATION. AND TESTING OF
AN 800 MEGAHERTZ TRUNKED RADIO COMMUNICATIONS SYSTEM
November, 1993
Prepared by:
800 MHz Proiect
Transition Committee
[Technical Subcommittee]
Police/Fire/Communications
Management of Information Services
300 N 'D' Street
San Bernardino, CA 92418
#:ZQ
TABLE OF CONTENTS
ARTICLE 1. STATEMENT OF PERFORMANCE ..................... I
1.1 MOTOROLA's Performance ............................ 1
1.1.1 Receiving Area ................................ 2
1.2 CITY's Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2
1.2.1 FCC License - Authorizations ....................... 2
1.2.2 CITY Facilities/Sites . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3
ARTICLE 2. TERM - IMPLEMENTATION AND PERFORMANCE
SCHEDULE .......................................... 3
2.1 Term........................................... 3
2.2 Implementation Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3
2.3 Performance Schedule ................................ 4
2.3.1 Implementation Schedule Obligations . . . . . . . . . . . . . . . . . .. 4
2.3.2 CITY's Obligations . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 4
2.3.3 800 MHz TRCS Sites ............................ 5
2.3.4 CITY Acquisition of Communications Sites and Facilities ...... 5
2.4 Failure to Perform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 6
ARTICLE 3. CONTRACT PRICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 6
3.1 Price - 800 MHz TRCS ............................... 6
3.2 Taxes.......................................... 7
3.3 Payment......................................... 7
3.4 Payment Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 7
3.5 General Option for Addition/Deletion . . . . . . . . . . . . . . . . . . . . . .. 7
3.5.1 Price Validity ................................. 9
3.6 Option to Purchase .................................. 9
ARTICLE 4. CITY APPRO V AL OF MOTOROLA DOCUMENTS AND
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 9
ARTICLE 5. SYSTEM PERFORMANCE AND ACCEPTANCE TESTING. . . .. 10
5.1 TRCS Acceptance Test Plan. . . . . . . . . . . . . . . . . . . . . . . . . . ., 10
5.1.1 Internal Testing ............................... 11
5.2 Functional Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 11
5.2.1 Performance Testing ............................ 11
5.3 Testing Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., 12
5.4 Test Responsibility ................................. 12
5.5 Evaluation of Test Data .............................. 13
5.6 Test Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 14
ARTICLE 6. Installation of TRCS. .............................. 14
6.1 Installation...................................... 14
6.2 Facilities........................................ 14
6.3 Loss, Damage to or Destruction of TRCS Equipment, Materials and
Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 14
6.3.1 CITY Responsibility ............................ 14
6.3.2 MOTOROLA Responsibility ....................... IS
6.4 Identification of Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 15
6.4.1 MOTOROLA Responsibility ....................... IS
6.5 Repair or Replacement of Equipment, Materials, Supplies or Software
Damaged or Destroyed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 15
6.5.1 MOTOROLA - Loss, Damage or Destruction . . . . . . . . . . . .. 15
6.5.2 CITY - Loss, Damage or Destruction. . . . . . . . . . . . . . . . .. 16
6.6 Standard of Work ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 16
6.7 Trammg........................................ 16
6.7.1 System Operator Training. . . . . . . . . . . . . . . . . . . . . . . .. 16
6.7.2 System Maintenance Training. . . . . . . . . . . . . . . . . . . . . .. 17
ARTICLE 7. WARRANTY AND MAINTENANCE. . . . . . . . . . . . . . . . . . .. 17
7.1 TRCS Equipment and Software Warranties and Services .......... 17
7.1.1 Parts Availability Warranty . . . . . . . . . . . . . . . . . . . . . . ., 19
7.2 Warranty Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., 19
7.3 Warranty Ownership, Authority ......................... 19
7.4 Compliance with Applicable Laws . . . . . . . . . . . . . . . . . . . . . . .. 20
7.5 TRCS Software Defects .............................. 20
7.6 Maintenance and Warranty Records ....................... 20
7.7 Copyright or Proprietary Data Notices ..................... 20
7.8 Confidentiality ofInformation . . . . . . . . . . . . . . . . . . . . . . . . . .. 20
7.9 Radio Coverage ................................... 21
ARTICLE 8. PERSONNEL ................................... 21
8.1 MOTOROLA Personnel .............................. 21
8.2 CITY Personnel Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 21
ARTICLE 9. AUTHORIZED REPRESENTATIVES ................... 21
9.1 CITY Representative ................................ 22
9.2 MOTOROLA Representative ........................... 22
ARTICLE 10. COMMUNICATIONS AND NOTICES .................. 22
10.1 Communications.................................. 22
10.2 Official CITY Address .............................. 22
10.3 Official MOTOROLA Address. . . . . . . . . . . . . . . . . . . . . . . . .. 23
ARTICLE 11. FINANCIAL REPORTS AND STATEMENTS ............. 23
ARTICLE 12. NON-INTERFERENCE WITH CITY AGENCIES . . . . . . . . . .. 25
ARTICLE 13. EXCUSABLE DELAYS OF PERFORMANCE ............. 25
ARTICLE 14. CHANGES, DELETIONS OR ADDITIONS TO AGREEMENT .. 25
14.1 CITY Change Requests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 25
14.2 Change Proposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 26
14.3 Change Order Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 27
14.4 MOTOROLA Change Requests . . . . . . . . . . . . . . . . . . . . . . . . .. 27
14.5 Changes in CITY's Total Obligation . . . . . . . . . . . . . . . . . . . . . .. 27
ARTICLE 15. DISPUTES .................................... 28
15.1 General ........................................ 28
15.2 Procedure....................................... 28
15.3 Attorney's Fees ................................... 28
ARTICLE 16. TERMINATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 28
16.1 CITY's Right to Terminate ............................ 29
16.2 Notification of Termination ............................ 29
16.3 Effect of Termination Notification . . . . . . . . . . . . . . . . . . . . . . .. 30
16.4 Invoicing of Non-Default Termination Expenses. . . . . . . . . . . . . . .. 30
16.5 Determination of Costs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 31
16.6 Failure to Agree on Cost. . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 31
16.7 Payment in Case of Dispute Re: Termination Costs ............. 32
16.8 Deductions from Agreed to Costs ........................ 32
ARTICLE 17. LIABILITY .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 32
17.1 Indemnification.................................... 32
17.2 Indemnification Regarding Patent Rights, Copyrights, Proprietary Data
and Trade Secrets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 33
17.3 Liquidated Damages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 33
ARTICLE 18. BONDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 34
18.1 Faithful Performance and Payment Bond . . . . . . . . . . . . . . . . . . .. 34
18.2 Bond Form and Penal Amounts. . . . . . . . . . . . . . . . . . . . . . . . .. 34
ARTICLE 19. RIGHT TO RETAIN A CONSULTANT(S) . . . . . . . . . . . . . . .. 34
ARTICLE 20. INCORPORATION OF EXHIBITS AND DEFINITIONS ...... 35
20.1 Incorporation of Exhibits . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., 35
20.2 Definition of "CITY" . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 35
20.3 Definition of "MOTOROLA" . . . . . . . . . . . . . . . . . . . . . . . . . .. 36
ARTICLE 21. ORDER OF PRECEDENCES BETWEEN AGREEMENT AND
EXHIBITS .......................................... 36
ARTICLE 22. GENERAL PROVISIONS . . . . . . . . . . . . . . . . . . . . . . . . . ., 36
22.1 Construction of Provisions and Titles Herein .................. 36
22.2 Number of Originals .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 36
22.3 Severability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ., 37
22.4 Applicable Law, Interpretation and Enforcement . . . . . . . . . . . . . . .. 37
22.5 Time of Effectiveness ................................ 37
22.6 Integrated Agreement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 37
22.7 Amendment ...................................... 38
22.8 Breach. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 38
22.9 Independent Contractor ............................... 38
22.10 Prohibition Against Assignment or Delegation . . . . . . . . . . . . . . . .. 38
22.11 Permits ........................................ 39
22.12 Nondiscrimination and Affirmative Action ................... 39
22.13 Claims for Labor and Materials . . . . . . . . . . . . . . . . . . . . . . . . ., 39
22.14 Insurance ....................................... 39
22.14.1 Insurance Certificates . . . . . . . . . . . . . . . . . . . . . . . . .. 40
22.14.2 Insurance Endorsements. . . . . . . . . . . . . . . . . . . . . . . .. 41
22.14.3 Waiver of Subrogation ......................... 41
22.14.4 Primary Insurance ............................ 41
22.14.5 Self-Insurance and Self-Insured Retentions ............. 41
22.14.6 Failure to Procure Insurance . . . . . . . . . . . . . . . . . . . . .. 41
22.14.7 Underlying Insurance .......................... 41
22.15 Consent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 42
22.16 Survival .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 42
22.17 Waivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 42
22.18 Time of Essence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 42
22.19 Promotional Tours. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 42
22.20 Substitutions ..................................... 42
ARTICLE 23. LIMITATION OF LIABILITY ....................... 43
ARTICLE 24. GLOSSARY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 43
EXHmIT A .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 45
STATEMENT OF WORK ..... . . . . . . . . . . . . . . . . . . . . . . . . . . .. 45
EXHmIT B .............................................. 46
IMPLEMENTATION SCHEDULE . . . . . . . . . . . . . . . . . . . . . . . . . . .. 46
EXHmIT C .............................................. 47
MILESTONES AND SYSTEM PAYMENT SCHEDULE. . . . . . . . . . . . .. 47
EXHmIT D ...... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 48
ADD AND DELETE SCHEDULE . . . . . . . . . . . . . . . . . . . . . . . . . . .. 48
EXHmIT E .............................................. 49
PURCHASED EQUIPMENT LIST . . . . . . . . . . . . . . . . . . . . . . . . . . .. 49
EXHmIT F .............................................. 50
OPTIONAL SPARE PARTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 50
EXHmIT G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 51
MOTOROLA "FNE INSTALLATIONS" QUALITY STANDARDS ....... 51
EXHmIT H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 52
SOFTW ARE LICENSES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 52
AGREEMENT BETWEEN THE CITY OF SAN BERNARDINO, CALIFORNIA
AND MOTOROLA COMMUNICATIONS AND ELECTRONICS, INC.
FOR THE DESIGN, IMPLEMENTATION AND TESTING OF
AN 800 MEGAHERTZ TRUNKED RADIO COMMUNICATIONS SYSTEM
This Agreement is entered into by and between the City of San Bernardino (hereinafter
referred to as the CITY) and MOTOROLA Communications and Electronics, Inc. an Illinois
Corporation, with its principal offices located at 1301 East Algonquin Road, Schaumburg,
Illinois (hereinafter referred to as "MOTOROLA"), with respect to the following facts:
WITNESSETH:
WHEREAS, the CITY desires to purchase a fully operational "turnkey" 800 MHz
Trunked Radio Communications System (hereinafter referred to as TRCS) for an integrated
public safety radio communications system operating in the 800 megahertz band.
WHEREAS, the CITY desires to purchase the equipment, materials and services that are
necessary to provide a complete 800 MHz trunked communications system for the CITY.
WHEREAS, the parties hereto wish to enter into an Agreement pursuant to which
MOTOROLA shall perform the work and furnish the equipment, materials and services as more
particularly described herein for the consideration and upon the terms and conditions as
hereinafter provided.
NOW, THEREFORE, in consideration of the above premises and of the covenants and
representations herein contained, the parties hereto covenant and represent as follows:
ARTICLE 1. STATEMENT OF PERFORMANCE
1.1 MOTOROLA's Perfonnance
MOTOROLA shall engineer, design, develop, produce, deliver to the CITY, install,
integrate, interface, and test the 800 MHz Motorola Trunked Radio Communications
System. Motorola shall install, integrate, interface, and test the system equipment and
interfaces as identified and described in this Agreement, and as detailed in Exhibit A, the
document entitled "DESIGN and IMPLEMENT A nON" . In so doing MOTOROLA
shall perform the work and deliver the items described in said document and other
Exhibits incorporated herein and, notwithstanding any other provision of this Agreement,
I
perform such other work and deliver such other items as are necessary to ensure that the
Communication System for which MOTOROLA is responsible hereunder meets all of the
operational and other requirements set forth in this Agreement.
1.1.1 Receiving Area
Equipment will be delivered to a CITY provided facility for inventory and equipment
check-out prior to installation at the sites.
MOTOROLA and the CITY will jointly inventory the equipment at the receiving/storage
area and shall immediately reconcile any discrepancies. A joint inventory list shall be
prepared. No equipment shall be released from the receiving/storage area without
authorization by the CITY representative who shall assure that the equipment is logged
out for application at a designated site. Copies of log sheets will be maintained jointly
by the CITY and MOTOROLA.
All sales and deliveries will be made F.O.B. Destination to purchaser facilities, or local
MOTOROLA storage facilities or any combination thereof. Title to the equipment shall
pass to the CITY upon delivery to the F.O.B. point. After delivery to CITY facilities,
risk of loss and damage to the articles shall be borne by the CITY. The above not
withstanding title to software and any third party supplied software shall not pass upon
payment of the license fee or under any circumstances.
1.2 CITY's Performance
1.2.1 FCC License - Authorizations
The CITY is solely responsible for obtaining any licenses or other related authorizations
required by the Federal Communications Commission ("FCC"). Neither MOTOROLA
nor any of its employees is an agent or representative of the CITY in FCC matters or
otherwise. MOTOROLA, however, may assist the CITY in obtaining licenses at no
charge to the CITY. The CITY and MOTOROLA acknowledge that project
implementation is dependent on receipt of proper FCC licensing.
1.2.2 CITY Facilities/Sites
The CITY shall, in addition to responsibilities described elsewhere in this Agreement,
2
perform the following coincident with MOTOROLA's performance of this Agreement:
(a) Provide ingress and egress to CITY's owned facilities and/or City of San
Bernardino sites as reasonably requested by MOTOROLA, and have such
facilities available for installation of the equipment to be installed.
(b) Provide dedicated 20 amp AC circuits at 117 V AC 60 Hz for the base site
equipment.
(c) Provide a designated work area with adequate heat and light, and a secure storage
area for equipment delivered to the CITY.
ARTICLE 2. TERM - IMPLEMENTATION AND PERFORMANCE SCHEDULE
2.1 Tenn
The term of this Agreement shall commence on its effective date and terminate when all
performance required hereunder is complete. The effective date is the date this
Agreement is approved by the CITY as indicated on the signature page.
2.2 Implementation Schedule
An Implementation Schedule shall be prepared by MOTOROLA. This schedule shall
indicate in detail all of the TRCS tasks and related sub tasks (including equipment,
delivery, installation, testing, etc.) to be performed for each subsystem which is part of
the "turnkey" 800 MHz trunked communications system, the dates said tasks and
subtasks shall be completed, and a final completion date. No equipment shall be
scheduled for delivery more than four (4) weeks prior to its scheduled installation. The
implementation schedule shall be attached hereto as Exhibit B.
2.3 Perfonnance Schedule
A Performance Schedule shall be prepared and updated by MOTOROLA every 30 days
to indicate the actual and projected completion dates of the tasks and subtasks identified
in the Implementation Schedule. The relationship between these Schedules and
MOTOROLA's and the CITY's obligations are defined in Sections 2.3.1, 2.3.2, 2.3.3,
3
and 2.3.4.
2.3.1 Implementation Schedule Obligations
Except for meeting the final completion date for the total Communications System and
the liquidated damages provisions of Article 17.3, Liquidated Damages, MOTOROLA
shall be deemed to have complied with the Implementation Schedule obligations if actual
completion dates of the Performance Schedule and updates reasonably and substantially
meet the completion dates set forth in the Implementation Schedule. Nothing in this
ARTICLE is intended to relieve MOTOROLA from its obligations to complete each task
and subtask identified therein.
2.3.2 CITY's Obligations
MOTOROLA's ability to reasonably and substantially meet its schedule obligations is in
part dependent upon the CITY adhering to its obligations as set forth in this Agreement
and Exhibits hereto. The parties agree that any failure in this regard may adversely
affect MOTOROLA's ability to perform. In this connection, the CITY agrees to inform
MOTOROLA, at the earliest time reasonably possible, of any projected inability of the
CITY to adhere to its obligations. MOTOROLA will reasonably cooperate with the
CITY to minimize, and if possible eliminate, the impact on MOTOROLA's work of any
projected inability or failure of the CITY or the CITY's other contractors to adhere to
its obligations. However, except as provided in ARTICLE 2.3.4, City Acquisition of
Communications Sites and Facilities, MOTOROLA will not be obligated to incur,
without reimbursement, additional costs in its performance of this Agreement as a result
thereof. Payment for such additional costs incurred in the performance of this
Agreement shall be accomplished through the Change procedure set forth in ARTICLE
14.
2.3.3 800 MHz TRCS Sites
The TRCS will utilize the sites which are identified in Exhibit A, the DESIGN and
IMPLEMENTATION. Should it be determined by either MOTOROLA or the CITY
during the course of performance on this Agreement that the sites or contigurations
selected are no longer available or desired, new or replacement sites or configurations
will be selected by the CITY. If any price adjustments are necessary as a result of these
new or replacement sites, such price adjustments will be added to this Agreement by
4
change order in accordance with ARTICLE 14 of this Agreement.
2.3.4 CITY Acquisition of Conununications Sites and Facilities
CITY acquisition of communications sites and facilities may require CITY coordination
and formal arrangements for site acquisition and access, and facilities construction. The
CITY will use its best efforts to provide all sites and facilities by the scheduled
occupancy dates. MOTOROLA shall schedule and reschedule its efforts so that no
additional compensation will be due it, and no such additional compensation shall be paid
by the CITY, as a result of any delay in the availability of any communications site or
facility to be provided by the CITY, except as provided herein. In the event
MOTOROLA is unable to schedule/reschedule its work to eliminate the effects of such
a delay, MOTOROLA shall notify CITY of its inability to so schedule/reschedule, the
reasons Gustification) for its inability, the impact MOTOROLA believes the delay will
have on the cost and scheduling of the work delayed, and justifications for the cost and
scheduling impact. In the event the cumulative total delays which cannot be so
scheduled/rescheduled extend the project final completion date by more than sixty (60)
calendar days, CITY shall reimburse MOTOROLA for any reasonable additional costs
incurred as a direct cause of such delays, but only for that portion of the delays
exceeding sixty (60) calendar days. If any individual, site or facility delay exceeds thirty
(30) days, MOTOROLA and the CITY will negotiate any impact to both cost and
schedule and such delay will not be included as part of the above stated cumulative sixty
(60) days. Notwithstanding any other provision to the contrary, during the period of the
delay in availability of any such site or facility, the parties shall use the change order
procedure set forth in ARTICLE 14, Changes, to arrive at mutually acceptable revisions
in the Implementation Schedule.
2.4 Failure to Perform
If MOTOROLA or its subcontractors fail to perform the work defined in Exhibit A,
DESIGN and IMPLEMENTATION, within the project schedule, CITY shall schedule
and reschedule its efforts so that no additional compensation will be due it, and no such
additional compensation shall be paid by MOTOROLA, as a result of any delay that is
caused by MOTOROLA or its subcontractors, except as provided herein. In the event
CITY is unable to schedule/reschedule its work to eliminate the effects of such a delay,
CITY shall notify MOTOROLA of its inability to so schedule/reschedule, the reasons
Gustification) for its inability, the impact CITY believes the delay will have on the cost
5
and scheduling of the work delayed, and justifications for the cost and scheduling impact.
In the event the cumulative total delays which cannot be so scheduledlrescheduled extend
the project final completion date by more than sixty (60) calendar days, MOTOROLA
shall reimburse CITY in accordance with Article 17.3, Liquidated Damages, of this
Agreement, but only for that portion of the delays exceeding sixty (60) calendar days.
If any individual delay exceeds thirty (30) days, CITY and MOTOROLA will negotiate
any impact to both cost and schedule and such delay will not be included as part of the
above stated cumulative sixty (60) days. Notwithstanding any other provision to the
contrary, during the period of the delay in availability of any such site or facility, the
parties shall use the change order procedure set forth in ARTICLE 14, Changes, to
arrive at mutually acceptable revisions in the Implementation Schedule.
ARTICLE 3. CONTRACT PRICE
3.1 Price - 800 MHz TRCS
For and in consideration of the 800 MHz trunked radio communications system,
including the supplies and implementation services to be performed by MOTOROLA as
described in this Agreement and its Exhibits, the CITY agrees to pay MOTOROLA a not
to exceed price of $ 1 , 48 6 , 3 9 8 . 36 unless authorized change orders are made
pursuant to the expressed provisions of Article 14 of the Agreement. This price is as
detailed in the MOTOROLA Price Summary, Exhibit E, Purchased Equipment List.
3.2 Taxes
The prices set forth in the Agreement are exclusive of any amount of Federal, State or
local excise, sales, lease, gross income service, rental, use, property, occupation or
similar taxes. If any taxes are determined applicable to this transaction and
MOTOROLA is required to payor bear the burden thereof, the CITY agrees to pay to
MOTOROLA the amount of such taxes and any interest or penalty thereon no later than
thirty (30) days after receipt of an invoice thereof. MOTOROLA will identify all
applicable taxes as separate line items on all MOTOROLA invoices.
3.3 Payment
The City reserves the right to withhold any lease payment as it becomes due should
Motorola fail to complete this project within the established timeline and to the City's
6
satisfaction.
3.4 Payment Provisions
Subject to the provisions of ARTICLE 15, Disputes and ARTICLE 18, Bonds, the timely
payment of all amounts due MOTOROLA herein shall be a condition precedent to the
continuance of work by MOTOROLA.
3.5 General Option for Addition/Deletion
MOTOROLA grants to CITY the option to delete from this Agreement any of the
equipment listed or services to be provided, and to add to this Agreement any of the
equipment listed or services to be provided at the lowest per-item cost as shown on
Exhibit E, Purchased Equipment List, subject to the following:
(a) If an item of MOTOROLA manufactured equipment is cancelled after it has been
shipped, but the item of equipment can be used elsewhere in this project, there
will be no additional charge to CITY.
(b) If an item of MOTOROLA manufactured equipment is cancelled after it has been
shipped, and that item of equipment cannot be used elsewhere in this project, the
CITY will be required to either pay any restocking charges, or purchase that item
of equipment, at the CITY's option.
(c) If an item of non-MOTOROLA manufactured equipment is cancelled after it has
been shipped and cannot be used elsewhere in the project, it will be subject to the
cancellation, restocking or equipment return policy of the equipment supplier.
(d) If an item of non-MOTOROLA manufactured equipment is cancelled after it has
been shipped, but the item can be used elsewhere in this project, there will be no
additional charge to the CITY.
(e) For each add or delete option exercised by CITY, CITY shall be required to pay
or shall be granted credit against the contract amount, as the case may be, in the
amounts specified in Exhibits D, and E, and F, Add and Delete Schedules,
Purchased Equipment List, and Optional Spare Parts.
7
(f) Add and delete options shall be exercised by written amendment to this
Agreement under Article 14 of this Agreement. Verbal notification in emergency
situations will be accepted: 1) if received either from CITY's Representative or
CITY Purchasing; and, 2) confirmed in writing within the same day via FAX.
Except as limited by Article 3.5(g), below, MOTOROLA shall agree to all such
amendments.
(g) An item shall be considered to have been "cancelled" upon notification to
MOTOROLA when applicable to MOTOROLA manufactured equipment, and
upon notification by MOTOROLA to the equipment supplier when applicable to
non-MOTOROLA manufactured equipment. MOTOROLA shall exercise its best
efforts to notify its suppliers immediately upon notification by CITY of any such
cancellation.
3.5.1 Price Validity
The prices reflected in Exhibit E, Purchased Equipment List, will remain valid for a
period of one year from contract award. Subsequent one year price validity renewals
shall be adjusted by the percentage increase/decrease in the Producer Price Index (PPI)
Commodity Index 1178 for Electronic Components and Accessories, with the base year
being the date of award. This validity is applied only to MOTOROLA manufactured
products and applies for years two (2) through four (4) from the contract award date.
Any non-MOTOROLA manufactured products shall be subject to their individual
manufacturer's price increases.
3.6 Option to Purchase
MOTOROLA grants every public entity which enters into an agreement with the CITY
to use any portion of the City of San Bernardino 800 MHz trunked radio communications
system the option to purchase the subscriber equipment as set forth in Exhibits E and F,
Purchased Equipment List and Optional Spare Parts List, provided that MOTOROLA and
said entity reach mutual agreement on purchase terms and conditions, delivery, payment
8
and warranty. Services will be as negotiated between MOTOROLA and said entity.
Said public entities may exercise this option independently of the CITY, upon notification
by CITY to MOTOROLA that the public entity is qualified under this section. The
prices for said equipment shall remain valid as set forth in Article 3.5.1, Price Validity,
of the Agreement.
ARTICLE 4. CITY APPRO V AL OF MOTOROLA DOCUMENTS AND
SPECIFICATIONS
Notwithstanding any other provision of this Agreement, approval by the CITY of
MOTOROLA engineering or design documents and specifications, or any part thereof,
shall not relieve MOTOROLA of the responsibility to meet all of the requirements for
the interface and 800 MHz TRCS as set forth in this Agreement and to correct any errors
or omissions in said documents. MOTOROLA shall have no claim for additional costs
on account of reasonable delays due to correction of errors or omissions in said
previously approved documents or revisions of said documents which may be found
necessary to comply with this Agreement. However, if any such delays cause reasonable
delays in MOTOROLA's performance of this Agreement, the Implementation Schedule
shall be extended by mutual agreement to account for such delay without penalty.
ARTICLE 5. SYSTEM PERFORMANCE AND ACCEPTANCE TESTING
5.1 TRCS Acceptance Test Plan
ACCEPTANCE CRITERIA
A. MOTOROLA will submit an Acceptance Test Plan (ATP), which demonstrates
system performance in accordance with the specifications contained herein, no
later than thirty (30) days prior to the commencement of the system test. The
CITY will then approve, conditionally approve or disapprove the proposed A TP
no later than 15 days prior to the commencement of the system test. Approval
of the ATP will be assumed by MOTOROLA in the absence of notifications
otherwise. See SOW section 1.10, Acceptance Test Plan. The successful
completion of the A TP and delivery of system documentation will be the sole
criterium for final system acceptance.
9
B. Should the CITY commence use of the system for its beneficial use, other than
for the express purposes of training or testing, prior to system acceptance, final
payment for the system shall be due net thirty (30) days. The warranty
maintenance period shall be deemed to have commenced concurrently with the
beneficial use of the system. Beneficial use of the system is defined as ten (10)
or more active radios.
C. Upon notification by MOTOROLA that the system is available for acceptance
testing, it is agreed that should the acceptance testing of the system or any
subsystem thereof be delayed for reasons beyond MOTOROLA's control, that
final payment for the subsystem or system shall become due net thirty (30) days
and warranty or maintenance shall commence upon notice to CITY by
MOTOROLA, unless the delay is also beyond the CITY's control. If a delay
occurs, beyond both MOTOROLA's and the CITY's control, the project schedule
will be adjusted accordingly.
MOTOROLA shall prepare an Acceptance Test Plan ("ATP") which states the
procedures for testing all of the physical, electrical, and functional specifications of the
800 MHz Motorola Trunked Radio Communications System. The ATP shall, as a
minimum, incorporate all of the requirements set forth below and shall be designed to
follow the Implementation Schedule.
5.1.1 Internal Testing
The A TP shall provide for the internal testing of each piece of equipment and its related
software, if any. Any equipment or software not meeting the requirements or
specifications specified in the DESIGN and IMPLEMENTATION or Motorola provided
Technical Specifications sheets shall be repaired or replaced by MOTOROLA without
additional cost to the CITY.
5.2 Functional Testing
The A TP shall provide for the functional testing of each piece of equipment and its
related software provided by MOTOROLA under this contract. Any equipment or
software not meeting the requirements or specifications shall be repaired or replaced by
MOTOROLA without additional cost to the CITY.
10
MOTOROLA shall provide a description of the procedures used for validating the
functional performance of the TRCS. Tests will exercise and validate the functional
performance of each subsystem and the entire system as a whole.
5.2.1 Perfonnance Testing
The ATP shall contain a detailed methodology for quantifying and validating, as
appropriate, the performance of the total system, each segment and each sub-system,
including, but not limited to: R.F. coverage, system overhead delay, system
functionality and operability, and system throughout capacity.
(a) The system must successfully complete a thirty (30) day performance test under
full actual load of the total system, without a major failure. A major failure is
defined as any failure that reduces the operation of the 800 MHz trunked radio
communications system and/or its flexibility by more than ten (10%) percent,
including mobile/portable radio failures (out of service) exceeding ten (10%)
percent of CITY's radio units. In the event of a major failure, the fault(s) will
be corrected by and at the sole expense of MOTOROLA, prior to reattempting
a thirty (30) day performance test.
(b) If successful performance of the full system cannot be accomplished within ninety
(90) days of initiation of system A TP, MOTOROLA may be deemed in default,
and the CITY may enforce the provisions of the performance bond or other
remedial measures, at the option of the CITY.
5.3 Testing Notice
MOTOROLA will notify CITY sufficiently in advance of all performance testing so that
CITY can determine and document the beginning and end of the thirty (30) day
performance test period, including any new test periods required as a result of a major
failure.
Not less than five (5) calendar days prior to conducting any test of the A TP,
MOTOROLA shall notify CITY of the date, time, and location of the test(s) to be
II
conducted.
5.4 Test Responsibility
The conduct of the 800 MHz trunked radio communications system Acceptance Test
Plan, and all testing identified by any terminology (e.g. unit testing, factory testing,
program testing, systems testing, installation and preliminary testing, external testing,
internal testing, functional testing and performance testing) shall be the responsibility of
MOTOROLA. It is recognized that a variety of testing procedures and equipment may
be utilized to conduct a particular test or to verify a particular specification. Therefore,
MOTOROLA will be afforded latitude in this regard provided the methods proposed are
regarded as acceptable in the industry and acceptable to the CITY. All tests performed
at CITY facilities or City communication sites shall be witnessed by CITY personnel
and the resulting program data shall be attested to and signed by MOTOROLA and the
CITY representative. The format to be used for recording of test program data shall be
submitted to the CITY for written approval prior to testing. All recorded test program
data shall be dated, witnessed and signed by a CITY representative and a MOTOROLA
representative. The entire test data shall be presented in a single test report, certifying
that such test data verifies that the tested elements of the system meet required
specifications and performance criteria, and shall be accepted by the CITY as set forth
below. MOTOROLA shall loan the necessary test equipment to the CITY during the
system acceptance test period.
5.5 Evaluation of Test Data
Upon completion of any testing, MOTOROLA shall promptly provide the test data to the
CITY for evaluation. MOTOROLA understands that the test data provided by
MOTOROLA must be evaluated by CITY in order to determine if the results of any such
test are within acceptable limits. Therefore, MOTOROLA agrees that the evaluation
shall constitute an integral part of any such test. The CITY's Representative shall
perform such evaluation within fifteen (15) calendar days after delivery to the CITY of
the data produced as a result of said test. In the event that the CITY's Representative
fails to complete and provide a written report indicating therein the results of the
evaluation to MOTOROLA within said fifteen (15) day period, the test shall be
conclusively presumed to have been successfully completed within acceptable limits. At
the conclusion of the evaluation phase, the CITY's Representative shall (if the test was
12
within acceptable limits), within five (5) calendar days thereof, provide MOTOROLA
with a written "Notice of Successful Completion" of the test and said Notice shall
constitute the formal acceptance of the test by the CITY. In the event of a negative
finding by the CITY's Representative (i.e., that the test was not successfully completed
within acceptable limits), he shall report thereon and set forth in writing the basis for
said findings. The report shall describe all deficiencies in sufficient detail to enable
MOTOROLA to correct such deficiencies. MOTOROLA shall then have forty-five (45)
calendar days within which to correct the deficiencies noted in the CITY's report. The
test shall be rescheduled and the CITY shall evaluate the results in the same manner as
set forth above. It is agreed that minor deficiencies or other minor errors that do not
reasonably affect the CITY's ability to operate the tested equipment in a user
environment may be identified in a "punch list" and, in such instance, the CITY's
Representative, at his discretion, may elect to conditionally accept the test results and to
make associated payments therefor, if any, with final acceptance of the test results and
further testing held in abeyance until the "punch list" items have been corrected by
MOTOROLA and verified by CITY.
5.6 Test Documentation
Test documentation of a pass/fail to previously specified criteria will be established by
MOTOROLA during test.
ARTICLE 6. Installation of TRCS.
6.1 Installation
MOTOROLA shall furnish all labor required for unpacking and placing of the delivered
hardware and software in the appropriate locations at the CITY designated facilities. The
equipment, software and related hardware delivered by MOTOROLA under this
Agreement shall be installed and placed in working order by MOTOROLA at their final
delivery locations.
6.2 Facilities
The CITY will not be obligated to provide for equipment, materials or supplies
warehousing prior to the respective facility occupancy dates set forth in the
Implementation Schedule and as specified in Article 2.3.4, CITY Acquisition of
Communications Sites and Facilities. MOTOROLA acknowledges that access to some
13
sites and facilities may be restricted by the CITY. Therefore, MOTOROLA agrees to
cooperate fully with all reasonable access requirements for deliver, installation and
testing of the TRCS.
6.3 Loss, Damage to or Destruction of TRCS Equipment, Materials and Supplies
6.3.1 CITY Responsibility
The CITY shall be responsible for loss, damage or destruction of all equipment,
materials and supplies provided by MOTOROLA, whether such loss, damage or
destruction occurs prior to CITY acceptance and payment therefor or after, provided the
loss, damage or destruction occurs through no fault of MOTOROLA, and when such
equipment, materials or supplies have been received at a CITY designated facility or
vehicle under the protective custody of the CITY. This provision does not relieve
MOTOROLA of the responsibility to use reasonable care in the protection of all such
equipment, materials or supplies or to provide the insurance required by Article 22.14.
6.3.2 MOTOROLA Responsibility
MOTOROLA shall be responsible for all loss, damage or destruction of all TRCS
equipment, hardware and software, and materials or supplies to be provided by
MOTOROLA prior to delivery to a CITY designated facility or vehicle under the
protective custody of the CITY.
6.4 Identification of Software
6.4.1 MOTOROLA Responsibility
MOTOROLA shall clearly label all in-development magnetic tapes, disc packs, cards,
listing and other software materials during the performance of its software work at CITY
facilities.
6.5 Repair or Replacement of Equipment, Materials, Supplies or Software Damaged or
Destroyed
14
6.5.1 MOTOROLA - Loss, Damage or Destruction
Prior to delivery to City facilities and during transit between City and Motorola facilities,
repair or replacement of lost, destroyed or damaged equipment, materials, supplies or
software for which MOTOROLA is responsible shall be made by MOTOROLA.
6.5.2 CITY - Loss, Damage or Destruction
After delivery to the City facilities and prior to final system acceptance, repair or
replacement of lost, destroyed or damaged equipment, materials, supplies or software for
which the CITY is responsible shall be made by the City. In the event of such repair or
replacement, the CITY and MOTOROLA will agree on a schedule adjustment and an
equitable price prior to MOTOROLA's undertaking the work. The price for this work
will become due and payable to MOTOROLA upon presentation of its invoice. The
repair or replacement need not be made until such agreement is reached.
6.6 Standard of Work
MOTOROLA shall perform all services required pursuant to this Agreement, including
but not limited to, the installation of which is provided for in this Agreement, in the
manner and according to the standards of the higher of MOTOROLA, as set forth in
Exhibit G, MOTOROLA's Quality Standards - "FNE Installations", or those observed
by a competent provider of services in the business in which MOTOROLA is engaged.
In the event that MOTOROLA, in its reasonable judgement, determines that a particular
practice or procedure is inappropriate in a particular situation, MOTOROLA may follow
whatever practice or procedure it deems appropriate providing that such practice or
procedure shall be at least that of the standard observed by a competent provider of
services in the business in which MOTOROLA is engaged. MOTOROLA agrees to
notify CITY of any such changed practices or procedures, either prior to implementation,
if practicable, or if not, as soon thereafter as is practicable.
6.7 Training
MOTOROLA will provide to the CITY printed technical, operational, and as-built
documentation relating to the operation and maintenance of the new system. Such
materials may be provided prior to or during training periods.
6.7.1 System Operator Training
15
MOTOROLA will provide on-site instruction to CITY personnel for the purpose of
training others in the use of the System, with an emphasis on operational functionality
presented with hands-on training of dispatcher operation and field unit operation as
defined in the STATEMENT OF WORK. A description of Motorola's training courses
is also presented in Exhibit A, Statement of Work.
6.7.2 System Maintenance Training
On-site, hands-on system maintenance trammg will be provided by qualified
MOTOROLA personnel experienced in the training of maintenance personnel regarding
the mechanics/electronics of the newly purchased system. Training materials will be
provided as part of the training as defined in the DESIGN and IMPLEMENTATION.
ARTICLE 7. WARRANTY AND MAINTENANCE
7.1 TRCS Equipment and Software Warranties and Services
A. System Warranty: MOTOROLA represents and warrants that all products,
software, and items delivered under this Agreement conform in design, materials
and workmanship to the SOW and appropriate manufacturer's Technical
Specifications. MOTOROLA further warrants that all products, software, and
other items delivered by MOTOROLA will interact according to the specifications
specified in the DESIGN and IMPLEMENTATION and the communications
coverage predictions. Successful completion of the A TP shall constitute full
compliance with and fulfillment of this warranty.
B. Hardware Warranty: MOTOROLA warrants that the radio communications
products delivered by this Agreement are free from defects in material and
workmanship for a period of one (1) year from the date of system acceptance,
except for crystal devices, channel elements, and crystal filters, which are
16
warranted for a period of ten (10) years from the date of shipment. Parts,
including crystals and channel elements, will be replaced free of charge for the
full warranty period. The labor to replace defective parts will be provided for
one-hundred, twenty (120) days from system acceptance. Thereafter, the CITY
must pay for the labor involved in repairing the product or replacing the parts at
the prevailing rates together with any transportation charges to or from the place
where warranty service is provided. The express warranty is extended by
MOTOROLA Communications and Electronics, Inc., 1301 E. Algonquin Road,
Schaumburg, Illinois 60196, to the original purchaser only.
C. Software Warranty: The warranty for MOTOROLA provided software shall be
covered by MOTOROLA for a period of one (I) year from the date of system
acceptance.
D. The expressed warranties contained in this section of this agreement are given in
lieu of all other warranties, expressed or implied, which are specifically excluded
including, without limitation, the implied warranties of merchantability and fitness
for a particular purpose. IN NO EVENT SHALL MOTOROLA BE LIABLE
FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES TO THE
FULL EXTENT SUCH MAYBE DISCLAIMED BY LAW.
E. In the event of a defect, malfunction or failure to conform to specifications
established by MOTOROLA, or if appropriate, to specifications accepted by
MOTOROLA in writing, during the period shown, MOTOROLA, at its option,
will either repair or replace the product or refund the purchase price thereof, and
such action on the part of MOTOROLA shall be the full extent of MOTOROLA's
liability hereunder.
The warranty is void if:
(a) the product is used in other than its normal and customary manner;
(b) the product has been subject to misuse, accident, neglect or damage;
(c) unauthorized alterations or repairs have been made, or unapproved parts used in the
equipment.
F. This warranty extends only to individual products; batteries are excluded but
carry their own separate limited warranty.
17
G. In order to obtain performance of this warranty, the CITY must contact its
MOTOROLA salesperson or MOTOROLA at the address first shown attention
Quality Assurance Department.
7.1.1 Parts Availability Warranty
MOTOROLA warrants the full and complete availability of all MOTOROLA
manufactured TRCS equipment parts, components, and service for a period of seven (7)
years following MOTOROLA notice of intent to cancel.
7.2 Warranty Period
The periods of the warranties set forth in this ARTICLE shall commence upon the actual
date that the TRCS system is accepted (final system acceptance) or placed in use by the
CITY in accordance with the provisions of ARTICLE 5.1 of this Agreement and
terminate as provided in ARTICLE 7.1. MOTOROLA shall provide CITY with a list
indicating the description and serial number of each piece of equipment in use. Said list
shall be delivered to CITY by or on the day of final system acceptance and updated by
delivery of a modified list with each shipment of additional TRCS related equipment
purchased by the City, from MOTOROLA, after the date of final system acceptance. In
all instances the warranty period shall commence on the date of final system acceptance
set forth in the A TP of ARTICLE 5, and it shall terminate as provided in ARTICLE 7.1.
7.3 Warranty Ownership, Authority
MOTOROLA warrants that it has full power and authority to grant the rights set forth
in this Agreement to the CITY with respect to the TRCS, its software and related
documentation without the consent of any other person; and that neither the performance
of the services by MOTOROLA nor the right to and use by the CITY of the TRCS, its
software and documentation (including the copying thereof as provided herein) will in
any manner constitute an infringement or other violation of any copyright, trade secret,
trademark, patent, invention, proprietary information, nondisclosure or other rights of
any third party. CITY understands that as part of this Agreement CITY may be required
to execute license agreements with the licensors of the software needed to operate the
TRCS as described in this Agreement and that CITY's possession and use of said
software shall be governed by the provisions of said license agreements in addition to the
18
provisions contained herein.
7.4 Compliance with Applicable Laws
MOTOROLA further warrants that TRCS, software, its license to and use by the CITY,
and the performance by MOTOROLA of the services provided hereunder, shall be in
compliance with all applicable laws, rules and regulations.
7.5 TRCS Software Defects
All software provided under this agreement will be repaired or replaced to correct
reproducible defects that cause a material variance from its published specification during
the warranty period as defined in Article 7. I.
7.6 Maintenance and Warranty Records
MOTOROLA shall maintain adequate records of all TRCS related hardware and software
maintenance and warranty work performed at any time by MOTOROLA and provide the
CITY with copies of all such records upon completion of such maintenance and warranty
work.
7.7 Copyright or Proprietary Data Notices
CITY shall affix copyright or proprietary data notices, as provided by MOTOROLA,
where necessary or proper in accordance with MOTOROLA's direction. CITY further
agrees to reproduce and include said copyright or proprietary data notices on any copies,
in whole or in part, in any form, for the TRCS as such notices may be requested in the
future by MOTOROLA.
7.8 Confidentiality of Information
The TRCS software, file structures, documentation, algorithms and related software
concepts except as otherwise provided herein, shall not be disclosed to any third party
in any manner without the written permission of MOTOROLA.
19
7.9 Radio Coverage
The City assumes responsibility for system coverage and excuses MOTOROLA from any
warrants for guarantee of radio communications coverage.
ARTICLE 8. PERSONNEL
8.1 MOTOROLA Personnel
The MOTOROLA key personnel to be assigned to the project shall be identified in
Article 9 and in Exhibit A, Statement of Work. MOTOROLA shall make its best effort
to retain these key personnel assigned to the project until its completion. Temporary or
permanent replacement of those individuals identified may occur only with prior written
approval of the CITY's Representative. MOTOROLA shall promptly replace any key
or other personnel upon the reasonable request of the CITY's Representative.
MOTOROLA shall at all times exercise reasonable care and diligence in enforcing
discipline and good order among its assigned personnel and in ensuring that the work is
executed in a timely and high quality manner.
8.2 CITY Personnel Support
The CITY shall make its best effort to retain key CITY personnel assigned to the project.
A written list of such personnel and their assignments shall be made available to
MOTOROLA within thirty (30) calendar days of the effective date of this Agreement.
In the event it becomes necessary to change CITY personnel assignments the CITY shall
provide written notification to MOTOROLA regarding such changes.
ARTICLE 9. AUTHORIZED REPRESENTATIVES
9.1 CITY Representative
The CITY hereby appoints Fred Wilson, or his successor or assignee to represent the
CITY with respect to all matters connected with this Agreement.
(a) Except for the Dispute Escalation Sequence described in Article 15.2, the CITY's
20
TRCS Project Manager is authorized to perform all roles and duties ascribed in
this Agreement to the CITY Representative.
9.2 MOTOROLA Representative
During the term of this Agreement, John Anderson, or his successor or assignee is
authorized to represent MOTOROLA with respect to all matters connected with this
Agreement.
ARTICLE 10. COMMUNICATIONS AND NOTICES
10.1 Communications
All official notices, demands, requests, consents, and approvals either party is required
or desires to give to the other shall be in writing and transmitted by U.S. mail, facsimile,
or by messenger; and delivery shall be deemed effective upon receipt at the addressee's
office or upon personal delivery to the addressee's office or upon personal delivery to
the addressee, whichever is applicable. All such notices, if to the CITY, shall be
addressed as set forth in ARTICLE 10.2 and if to MOTOROLA shall be addressed as
set forth in ARTICLE 10.3. Either party may change its address by notifying the other
party of the change and its effective data.
10.2 Official CITY Address
All written communications pertaining to this agreement from MOTOROLA to the CITY
shall be addressed as follows:
City of San Bernardino
Attn: Mr. Fred Wilson
300 N 'D' Street
San Bernardino, CA 92418
Additionally, MOTOROLA shall use its best efforts to send a copy of all written
communications pertaining to this agreement, via first class mail to:
THE COMMUNICATIONS GROUP
Attn: Kenyon Crabtree
21
1863 Montgomery Drive
Vista, California 92084
10.3 Official MOTOROLA Address
All written communication pertaining to this agreement from the CITY to MOTOROLA
shall be addressed as follows:
MOTOROLA Communications and Electronics, Inc.
1301 Algonquin SH/4
Schaumburg, IL. 60196
Attn: Mr. John Andersen
Additionally, CITY shall use its best efforts to send a copy of all written communications
pertaining to this agreement, via first class mail, to:
MOTOROLA Communications and Electronics, Inc.
1700 Iowa Avenue, Suite 190
Riverside, CA 92507
Attn: Rex Hamilton
and
THE COMMUNICATIONS GROUP
1863 Montgomery Drive
Vista, CA 92084
Attn: Mr. Kenyon Crabtree
ARTICLE 11. FINANCIAL REPORTS AND STATEMENTS
During the period of this Agreement MOTOROLA will provide the CITY with oral and
written financial data in the form of reports and statements as indicated herein. Such
reports shall be delivered to the CITY's Representative and will be limited to the
following specific types of financial data.
(a) Invoices for equipment and services provided to the CITY under this
22
agreement.
(b) Periodic summaries of payments received by MOTOROLA from the CITY.
(c) Projections of Milestone completions and related payments over specific future
time periods.
(d) Quotations in response to CITY requests as related to changes in the work.
23
ARTICLE 12. NON-INTERFERENCE WITH CITY AGENCIES
MOTOROLA's performance of work under this Agreement must not interfere
unnecessarily with the operation of any CITY Agency. If MOTOROLA, as a result of
its own operations or work efforts, disrupts or otherwise interferes with existing City
operations and causes a degradation or interruption of the City's performance of those
operations beyond the scheduled computer downtime, Motorola will assume responsibility
and costs incurred for resolution of the problem. If the CITY, as a result of its own
operations, substantially delays, disrupts or otherwise interferes with and changes
MOTOROLA's performance hereunder, schedule and/or price adjustments will be
determined mutually and accomplished by a change order in accordance with ARTICLE
14.
ARTICLE 13. EXCUSABLE DELAYS OF PERFORMANCE
The parties obligations to perform under this Agreement shall be suspended, without
forfeiture of any performance bond or the incurring of any financial liability , when and
for as long as such performance is prevented by reason of any of the following cases:
(a) acts of God, (b) operation of law, (c) the inability to obtain necessary materials,
supplies or equipment by reason of appropriation or use thereof by the State or Federal
Government or by reason of regulations imposed by the State or Federal Government,
(d) any acts of the enemies of the State of California or of the United States of America,
(e) an industry-wide strike, (I) mob violence, or, (g) fire and delays in transportation,
to the extent that they are not caused by the party's willful or negligent acts or omissions,
and to the extent that they are beyond the party's reasonable control. The
Implementation Schedule shall be adjusted consistent with the term of this delay.
ARTICLE 14. CHANGES, DELETIONS OR ADDITIONS TO AGREEMENT
14.1 CITY Change Requests
In the event that the CITY identifies changes or deletions to the work tasks specified in
this Agreement or additional work to be performed within the scope of the work set forth
in this Agreement, the CITY shall submit a request for such changes, deletions or
additions, in writing, in the following manner:
24
(a) The nature of the change, deletion or addition requested including a brief
description of any new or altered requirements, a description of the requested
work to be changed, deleted or added and, to the extent possible, whether or not
the CITY is willing to alter any requirement to accommodate the change,
deletion, or addition, reference to the portions of this Agreement, including
exhibits or attachments or other documents which will be affected.
14.2 Change Proposal
Within twenty (20) (ten (10) for CITY designated "priority" requests) CITY working
days following MOTOROLA's receipt of the CITY's written request for a change,
deletion or addition, MOTOROLA shall prepare and deliver to the CITY a written
statement which shall include the following data:
(a) Technical impact of the change, deletion or addition on existing requirements and
characteristics;
(b) Total cost of the change, addition or deletion;
(c) Estimated time schedule to incorporate the change, deletion or addition and its
impact on the Implementation Schedule;
(d) Impact of the change, deletion or addition on the suppliers, vendors or
subcontractors, if any;
(e) Impact of the change, deletion or addition on any other part of this Agreement
including exhibits, attachments or other documents which will be affected by a
request.
(f) Estimated California Sales or Use Tax Impact; and
(g) The period of time for which such statement is valid.
(h) Any alterations to this contract which cause an increase or decrease in the cost
or time required for the performance of any part of this contract shall not become
binding until both the CITY and MOTOROLA have agreed upon an equitable
adjustment and the contract has been modified in writing accordingly.
25
14.3 Change Order Notice
Upon acceptance by the CITY of MOTOROLA's written statement for a proposed
change, the CITY shall deliver to MOTOROLA a Change Order Notice, executed by the
CITY's Representative, or his designated representative, specifying the change to be
made and all of the particulars set forth in ARTICLE 14.1 and 14.2 above as agreed
upon, and except as otherwise provided herein, this Agreement and all pertinent Exhibits
and Attachments hereto shall be deemed amended in accordance with said Change Order
Notice(s); and related copy changes to said pertinent Agreement, exhibits, and
attachments shall be provided to the CITY by MOTOROLA, see Add and Delete
Schedules in Exhibit D.
14.4 MOTOROLA Change Requests
MOTOROLA may suggest to the CITY that changes be made to the work program
within the general scope of the work contemplated in this Agreement. Such suggested
changes may include, but shall not be limited to, substitutions, deletions or additions,
upgrading or enlarging the TRCS components. Such changes may also be suggested for
the purpose of adjusting the Implementation Schedule or meeting other TRCS
requirements. All such suggested changes shall be made in accordance with the
applicable provisions of ARTICLE 14.2 and 14.3 above and no such changes shall be
made without the prior written approval of the CITY's Representative.
14.5 Changes in CITY's Total Obligation
NOTWITHSTANDING Article 9.1, CITY Representative, or any other provision of this
Agreement, any changes or additions thereto which will increase the CITY's total
obligation set forth in ARTICLE 3.1 of this Agreement shall be accomplished by a
written amendment approved by the CITY. The CITY shall not be obligated for payment
of any such changes or additions made in violation of this ARTICLE.
Should the total obligation of the CITY be reduced by any changes, substitutions, or
deletions hereunder, the CITY shall be credited for such reduction which shall be suitably
defined and detailed upon the subsequent billing invoice to the CITY.
26
ARTICLE 15. DISPUTES
15.1 General
"Dispute" shall include every controversy arIsmg under or in connection with this
Agreement, its performance, or any acts or events done or occurring in connection with
the Communications System.
15.2 Procedure
Any dispute by either party shall be presented to the CITY for its consideration and
decision through the CITY's Representative. MOTOROLA and the CITY agree to
negotiate in good faith to resolve any dispute under this Agreement. Any dispute that
is not settled by agreement of both parties may be settled in the State or Federal Courts
of the State of California. MOTOROLA agrees to adhere to the decision of the CITY
and continue with all work on the TRCS except in situations where MOTOROLA feels
performance thereof shall jeopardize system performance. However, nothing herein is
meant to limit the rights of either party available by law.
15.3 Attorney's Fees
In any action at law or in equity by the CITY or MOTOROLA for recovery of any sum
or credit due under this Agreement, or to enforce any of the terms, covenants or
conditions contained herein, the prevailing party shall be entitled to reasonable attorney's
fees in addition to costs and necessary disbursements incurred in such action.
ARTICLE 16. TERMINATION
16.1 CITY's Right to Terminate
(a) If MOTOROLA fails to provide an operational system as described in the SOW,
or fails to make delivery or complete installation under the Agreement, the CITY
may consider MOTOROLA to be in default, unless such failure has been caused
by the conditions set forth in Article 13. The CITY shall give MOTOROLA
written notice of such default and MOTOROLA shall have thirty (30) days to
provide a mutually acceptable plan of action to cure said default. If
27
MOTOROLA fails to cure said default, the PURCHASER may terminate any
unfulfilled portion of this Agreement or complete the system through a third
party. In this event, CITY has the right to invoke the provisions of the
Performance Bond, executed per Article 18. In the event of default,
MOTOROLA shall not be liable for any incidental, special or consequential
damages, nor for any liquidated damages subsequent to default.
(b) In the event that the CITY chooses to terminate this contract solely for the
convenience of the CITY, MOTOROLA will, upon notification, take all
reasonable steps to minimize termination costs. The CITY shall be liable to
MOTOROLA for equipment and services provided to the date of notice to
terminate and for reasonable costs which may be borne by MOTOROLA in the
termination of subcontracts, removal of installation and test equipment, and other
costs directly related to an unforeseen and abrupt termination.
16.2 Notification of Termination
Any such termination shall be effected by delivery to MOTOROLA of a Notice of
Termination specifying whether termination is for the default of MOTOROLA or for the
CITY's convenience, the extent to which work under this Agreement is terminated, and
the date upon which such termination becomes effective. If, after Notice of Termination
of this Agreement for default it is determined by CITY or a court of competent
jurisdiction that MOTOROLA's failure to perform is due to causes specified in the
provisions of ARTICLE 13 of this Agreement (Excusable Delays of Performance) the
Notice of Termination shall be deemed to have been issued in the interests of the CITY
and the rights and obligations of the parties hereto shall in such event be governed
accordingly.
16.3 Effect of Termination Notification
After receipt of a Notice of Termination and except as otherwise directed by the CITY,
MOTOROLA shall stop work under this Agreement on the date and to the extent
specified in the Notice of Termination. MOTOROLA shall place no further orders or
subcontracts for materials, services, or facilities except as may be necessary for
completion of such portion of the work under this Agreement as is not terminated.
28
MOTOROLA shall terminate all orders and subcontracts to the extent that they relate to
the performance of work terminated by the Notice of Termination. The CITY shall settle
or pay any and all claims arising out of such orders and subcontracts assigned to the
CITY to the extent MOTOROLA has not been paid therefor and is not responsible for
such payments as the result of the CITY's notice of termination for its convenience. At
the CITY's option and with its prior approval, MOTOROLA shall settle all outstanding
liabilities and all claims arising out of the termination of such orders and subcontracts.
(a) MOTOROLA shall be paid for items it delivers hereunder. MOTOROLA and
the CITY shall work together in good faith to determine and agree upon the
whole or any part of the amount or amounts to be paid to MOTOROLA by
reason of the total or partial termination of work pursuant to this ARTICLE.
(b) MOTOROLA shall complete performance of such part of the work as shall not
have been terminated by the Notice of Termination. MOTOROLA shall take
such action as may be necessary, or as the CITY may direct, for the protection
and preservation of the property related to this Agreement which is in the
possession of MOTOROLA and in which the CITY has or may acquire an
interest.
(c) MOTOROLA shall proceed immediately with the performance of the obligations
specified in ARTICLE 16.3 notwithstanding any delay in determining or adjusting
the prices due under this Agreement.
16.4 Invoicing of Non-Default Tennination Expenses
After receipt of a Notice of Termination for CITY's convenience by MOTOROLA,
MOTOROLA shall submit to the CITY its invoices for its termination expenses. Such
invoices shall be submitted promptly, but in no event later than one hundred eighty (180)
calendar days from the effective date of termination, unless one or more extensions in
writing are granted by the CITY upon requests of MOTOROLA made in writing within
such period or any authorized extension thereof.
16.5 Detennination of Costs
Upon any termination for the convenience of the CITY, MOTOROLA and the CITY
shall work together in good faith to determine and agree upon the whole or any part of
29
the amount or amounts to be paid to MOTOROLA by reason of the total or partial
termination of work.
16.6 Failure to Agree on Cost
In the event of the failure of MOTOROLA and the CITY to agree in whole or in part,
as provided in Section 16.5, as to the amounts to be paid to MOTOROLA in connection
with the termination of work for the convenience of the CITY, MOTOROLA shall,
nevertheless, be entitled to payment for the following:
(a) All amounts and expenses incurred by MOTOROLA in the performance of the
work on this Agreement prior to said termination not previously paid to
MOTOROLA and such additional amounts as may be incurred out of necessity
within a reasonable time thereafter with the written approval of or as directed by
the CITY. Provided, however, that MOTOROLA shall proceed as rapidly as
practicable to discontinue all additional costs.
(b) So far as not included under Section 16.6(a), the costs of settling and paying
claims arising out of the termination of work under subcontracts or orders, as
provided in ARTICLE 16.3 which are related to the terminated portion of this
Agreement.
(c) The reasonable costs of settlement, including accounting, legal, clerical, and other
expenses reasonably necessary for the preparation of the invoices for termination
expenses and supporting data for the termination and settlement of subcontracts
hereunder, together with reasonable storage, transportation, and other costs
incurred in connection with the protection or disposition of termination inventory.
16.7 Payment in Case of Dispute Re: Termination Costs
If MOTOROLA disagrees with any determination made by the CITY, such difference
shall be resolved in accordance with ARTICLE 15 of this Agreement. In any case
where the CITY had made a determination of the amount due in accordance with
ARTICLE 16.4 or ARTICLE 16.6 the CITY shall pay such amount to MOTOROLA
forthwith. If a protest has been taken up to the CITY Representative, the CITY shall
also pay to MOTOROLA any additional amount finally determined to be due
30
MOTOROLA as a result of such protest.
16.8 Deductions from Agreed to Costs
In arriving at the amount due MOTOROLA under ARTICLE 16 there shall be deducted
(a) all payments theretofore made to MOTOROLA applicable to the terminated portion
of this Agreement, (b) any amount due the CITY from MOTOROLA in connection with
this Agreement, and (c) the Agreed price for, or the proceeds of sale of, any materials,
supplies, or other items acquired by MOTOROLA and sold pursuant to the provisions
of this ARTICLE and not otherwise recovered by or credited to the CITY.
ARTICLE 17. LIABILITY
17.1 Indemnification
MOTOROLA agrees to and hereby indemnifies and saves CITY harmless from all
liabilities, judgements, costs, damages and expenses which may accrue against, be
charged to, or recovered from the CITY by reason of or on account of damage to the
property of the CITY or the property of, injury to, or death of any person, when such
damage or injury is caused by MOTOROLA's negligence or that of its employees,
subcontractors, or agents while on the premises of the CITY during the delivery and
installation of the communications equipment. In no event will MOTOROLA be liable
for incidental, special or consequential damages.
17.2 Indemnification Regarding Patent Rights, Copyrights, Proprietary Data and Trade
Secrets
(a) MOTOROLA does hereby indemnify and shall hold harmless the CITY,
(hereinafter referred to as the "Indemnified Party") against all claims including
reasonable attorney's fees, arising out of or relating to the violation or alleged
violation, or infringement or alleged infringement of any trade secret, proprietary
information, trademark, copyright or patent right, in connection with the CITY's
use of the TRCS. MOTOROLA shall at CITY's option conduct the defense in
any such third party action arising as described herein and CITY promises fully
to cooperate with such defense. This indemnification is limited to the TRCS
31
delivered to the CITY or as modified by MOTOROLA and does not cover third
party claims arising from any modifications not authorized by MOTOROLA. .
(b) If a third party claim causes quiet enjoyment and use of the TRCS equipment,
hardware or software to be seriously endangered or disrupted, MOTOROLA shall
(I) replace the TRCS equipment, hardware or software, without additional
charge, by a compatible, functionally equivalent and non-infringing product; or
(2) retain the TRCS functions but modify the TRCS to avoid the infringement;
or (3) obtain a license for the CITY to continue use of the TRCS as provided in
this Agreement and pay for an additional fee required for such license.
17.3 Liquidated Damages
MOTOROLA agrees to pay Liquidated Damages in the amount of three hundred dollars
($300.00) per day for every day system acceptance is delayed beyond the dates set forth
in Exhibit B to the Agreement, Implementation Schedule. In no event will liquidated
damages extend past sixty (60) days. MOTOROLA will not be held responsible for any
damages that are assessed as a result of delays as defined in Article 13, or delays by the
CITY which shall include but are not limited to the providing of appropriate and required
information, timely access to sites, facilities and vehicles, licensing, and the providing
of outside services or any other causes outside of MOTOROLA's control. In no event
will MOTOROLA accept the assessment of liquidated damages once the CITY is using
the trunked radio communications system for its intended purpose.
ARTICLE 18. BONDS
18.1 Faithful Performance and Payment Bond
Within seven (7) calendar days of approval by CITY of this Agreement, MOTOROLA
shall post a Faithful Performance and Payment Bond from a corporate surety which is
satisfactory to the CITY:
(a) Conditioned for the faithful performance by MOTOROLA of all the terms,
covenants, and conditions of this Agreement; and
32
(b) As security for the prompt payment to all persons supplying labor and material
in the prosecution of the work to be performed under this Agreement and any and
all duly authorized modifications hereof.
18.2 Bond Fonn and Penal Amounts
Such bond shall be on a form to be approved by the CITY. The penal amount of the
bond shall be a penal sum equal to one hundred percent (100%) of the Total Price
specified in ARTICLE 3 to be paid to MOTOROLA for its performance hereunder,
without any deduction therefrom.
Recovery by the CITY under any performance bond(s) shall occur upon determination
of default in accordance with Section 16.1. In no event will liquidated damages extend
beyond the final determination of default.
ARTICLE 19. RIGHT TO RETAIN A CONSULTANT(S)
The CITY shall have the right to retain consultants and firm(s) in an advisory capacity
to assist the CITY in reviewing MOTOROLA's progress and technical efforts, and to
assist the CITY in other matters as the CITY may deem appropriate.
ARTICLE 20. INCORPORATION OF EXHffiITS AND DEFINITIONS
20.1 Incorporation of Exhibits
The following Exhibits are hereby incorporated into and made a part of this Agreement
hereafter referred to as though set forth at length, except where certain portions of
specific Exhibits have been deleted or superseded by other sections of this Agreement.
Exhibit A
Exhibit B
Exhibit C
Exhibit D
Exhibit E
STATEMENT OF WORK
Implementation Schedule
Milestones and System Payment Schedule
Add and Delete Schedule
Purchased Equipment List
33
Exhibit F
Exhibit G
Exhibit H
Optional Spare Parts
Motorola "FNE Installations" Quality Standards
Software Licences
Any reference to the "Agreement" in these documents includes this document and
Exhibits A through H. The effect, significance and applicability of the various Exhibits
or Sections thereof are as specified in those portions of the Agreement which make
specific reference to them.
20.2 Definition of "CITY"
Unless otherwise specified, whenever the term "the CITY" or "CITY" is used in this
Agreement, it shall mean and include the City of San Bernardino, California, its officers,
agents and employees.
20.3 Definition of "MOTOROLA"
Unless otherwise specified, whenever the term "MOTOROLA" is used in this
Agreement, it shall mean and include MOTOROLA Communications and Electronics,
Inc. its officers, agents, employees, suppliers and subcontractors.
ARTICLE 21. ORDER OF PRECEDENCES BETWEEN AGREEMENT AND EXHffiITS
In the event of an inconsistency between any of the provisions of this Agreement and/or
the Exhibits hereto, the inconsistency shall be resolved by giving precedence in the
following order:
1. Articles of this Agreement
2. Exhibit A, STATEMENT OF WORK
3. Exhibit E, Purchased Equipment List
4. Exhibit B, Implementation Schedule
5. Exhibit C, Milestones and System Payment Schedule
34
ARTICLE 22. GENERAL PROVISIONS
22.1 Construction of Provisions and Titles Herein
All titles or subtitles appearing herein have been inserted for convenience and shall not
be deemed to affect the meaning or construction of any of the terms or provisions hereof.
The language of this Agreement shall be construed according to its fair meaning, not
strictly for or against the CITY or MOTOROLA, and not against either party as its
drafter since both parties agree they had an equal hand in drafting this Agreement. The
singular shall include the plural; use of the feminine, masculine, or neuter genders shall
be deemed to include the genders not used.
22.2 Number of Originals
The number of original texts of this Agreement shall be equal to the number of the
parties hereto, one text being retained by each party. In the event of a conflict between
the two original texts, the copy maintained by the CITY Representative shall control.
22.3 Severability
If any portion of this Agreement or any exhibits or portion thereof is held to be invalid
by a court of law such provision shall be considered severable, and the remainder of this
Agreement or any provision hereof shall not be affected.
22.4 Applicable Law, Interpretation and Enforcement
Each party's performance hereunder shall comply with all applicable laws of the United
States of America, the State of California, and the CITY. This Agreement shall be
enforced and interpreted under the laws of the State of California and the CITY.
22.5 Time of Effectiveness
Unless otherwise provided this Agreement shall take effect when all of the following
events have occurred:
35
(a) This Agreement has been signed on behalf of MOTOROLA by the person or
persons authorized to bind MOTOROLA hereto; and
(b) This Agreement has been approved by the CITY.
This Agreement will be in effect as of the last date of signature.
22.6 Integrated Agreement
This Agreement sets forth all of the rights and duties of the parties with respect to the
subject matter hereof, and replaces any and all previous agreements or understandings,
whether written or oral, relating thereto. This Agreement may be amended only as
provided for in Article 22.7 hereof.
22.7 Amendment
All amendments hereto shall be in writing and signed by the persons authorized to bind
the parties thereto. The CITY Representative shall approve all amendments for the CITY
except those identified under Article 14.5 entitled "Changes in CITY's Total Obligation"
providing for expressed approval by the CITY.
22.8 Breach
Except for excusable delays, if any party fails to perform, in whole or in part, any
promise, covenant, or agreement set forth herein, or should any representation made by
it be untrue, any aggrieved party may avail itself of all rights and remedies, at law or
equity, in the courts of law. Said rights and remedies are cumulative of those provided
for herein except that in no event shall any party recover more than once, suffer a
penalty or forfeiture, or be unjustly compensated. MOTOROLA and CITY agree to
utilize the disputes resolution procedure of Article 15, Disputes, prior to commencing
any legal or equitable action.
22.9 Independent Contractor
MOTOROLA is acting hereunder as an independent contractor and not as an agent or
employee of the CITY. MOTOROLA shall not represent or otherwise hold out itself or
any of its directors, officers, partners, employees, or agents to be an agent or employee
36
amounts due under the Unemployment Insurance Act with respect to such labor.
22.14 Insurance
In order to accomplish the indemnification herein provided for, but without limiting the
indemnification, MOTOROLA shall secure and maintain throughout the term of the
contract the following types of insurance with limits as shown:
(a) Workers Comoensation
A program of worker's compensation insurance or a State-approved Self
Insurance Program in an amount and form to meet all applicable requirements of
the Labor Code of the State of California, including Employer's Liability with
$250,000 limits, covering all persons providing services on behalf of
MOTOROLA and all risks to such persons under this Agreement.
(b) Comorehensive General and Automobile Liability Insurance
This coverage to include contractual coverage and automobile liability coverage
for owned, hired, and non-owned vehicles. The policy shall have combined
single limits for bodily injury and property damage of not less than one million
dollars ($1,000,000).
(c) Contractual Liability - Work Contracts
The liability policy shall include Contractual Liability Coverage designed to
protect the CITY for contractual liabilities assumed by MOTOROLA in the
performance of the contract.
(d) Subcontractor's Public Liability and Prooerty Damag:e Insurance
MOTOROLA shall require each of his subcontractors to secure and maintain
during the life of the contract, insurance of the types specified above or insure the
activities of his subcontractors in his policy, as specified above.
(e) Broad Form Property Dama!!e Coverages and Comoleted Operations
The liability policy shall include Broad Form Property Damage Coverage and
Completed Operations.
22.14.1 Insurance Certificates
38
of the CITY.
22.10 Prohibition Against Assignment or Delegation
MOTOROLA may not, unless it has first obtained the written permission of the CITY;
(a) Assign or otherwise alienate any of its rights hereunder, including the right to
payment; or
(b) Delegate, subcontract, or otherwise transfer any of its duties hereunder.
22.11 Pennits
MOTOROLA and its officers, agents and employees shall obtain and maintain permits
that apply to the installation of the defined MOTOROLA equipment and as stated in the
STATEMENT OF WORK, Exhibit A.
22.12 Nondiscrimination and Affinnative Action
MOTOROLA shall comply with the applicable nondiscrimination and affirmative action
provisions of the laws of the United States of America, the State of California, and the
CITY. In performing this Agreement, MOTOROLA shall not discriminate in its
employment practices against any employee or applicant for employment because of such
person's race, religion, national origin, ancestry, sex, sexual orientation, age, or physical
handicap. MOTOROLA shall also comply with all rules, regulations, and policies of the
CITY relating to nondiscrimination and affirmative action, including the filing of all
forms required by said Office. Any subcontract entered into by MOTOROLA relating
to this Agreement, to the extent allowed hereunder, shall be subject to the provisions of
this Article.
22.13 Claims for Labor and Materials
MOTOROLA shall promptly pay when due all amounts payable for labor and materials
furnished in the performance of this Agreement so as to prevent any lien or other claim
under any provision of law from arising against any CITY property (including reports,
documents, and other tangible matter produced by MOTOROLA hereunder), against
MOTOROLA's rights to payments hereunder, or against the CITY, and shall pay all
37
MOTOROLA shall furnish certificates of insurance and copies of all policies and
endorsements to the CITY evidencing the insurance coverage above required prior to the
commencement of performance of services hereunder, which certificates shall provide
that such insurance shall not be terminated or expire without thirty (30) days written
notice to the CITY, and shall maintain such insurance from the time MOTOROLA
commences performances of services hereunder until the completion of such services.
22.14.2 Insurance Endorsements
All policies, with respect to the insurance coverage above required, except for the
Workers' Compensation insurance coverage and professional liability coverage, if
applicable, shall contain additional endorsements naming the CITY, its employees,
agents, volunteers and officers as additional named insured with respect to liabilities
arising out of the performance of services hereunder.
22.14.3 Waiver of Subrogation
MOTOROLA shall require the carriers of the above required coverages to waive all
rights or subrogation against the CITY, its officers, volunteers, employees, contractors
and subcontractors.
22.14.4 Primary Insurance
All policies required above are to be primary and non-contributing with any insurance
or self-insurance programs carried or administered by the CITY.
22.14.5 Self-Insurance and Self-Insured Retentions
Self-insurance programs and self-insured retentions in insurance policies are subject to
separate approval by the CITY upon review of evidence of MOTOROLA's financial
capacity to respond. Additionally, such programs or retentions must provide the CITY
with at least the same protection from liability and defense of suits as would be afforded
by first-dollar insurance.
22.14.6 Failure to Procure Insurance
MOTOROLA's failure to procure and maintain the required insurance or self-insurance
39
program during the entire term of this Agreement shall constitute a material breach of
this Agreement under which the CITY may immediately terminate this Agreement or,
at its discretion, procure or renew such insurance to protect CITY's interests and pay any
and all premiums in connection therewith, and recover all monies so paid from
MOTOROLA.
22.14.7 Underlying Insurance
MOTOROLA shall be responsible for requiring indemnification and insurance as it
deems appropriate from its employees receiving mileage allowance, agents and
subcontractors, if any, to protect MOTOROLA's and the CITY's interests, and for
ensuring that such persons comply with any applicable insurance statutes.
22.15 Consent
Whenever consent or approval of either party IS required, that party shall not
unreasonably withhold such consent or approval.
22.16 Survival
The obligations of the parties which, by their nature, continue beyond the term of this
Agreement, will survive the termination of this Agreement.
22.17 Waivers
No waiver by either party of any provisions of this Agreement shall be deemed to be a
waiver of any other provision hereof or of any subsequent breach by either party of the
same or any other provisions.
22.18 Time of Essence
Time is of the essence of each provision of this Agreement which specifies a time within
which performance is to occur. In the absence of any specific time for performance,
performance may be made within a reasonable time.
22.19 Promotional Tours
To protect the privacy, operational effectiveness, and integrity of CITY's use of the
40
TRCS, MOTOROLA will refrain from arranging or encouraging promotional or other
visits or telephone calls to CITY, except as specifically approved in advance by the
CITY's Representative or his designee.
22.20 Substitutions
During performance of this project, it is understood that MOTOROLA may implement
changes in the products set forth in the proposal, or substitute products of more recent
design; provided, however, that any such changes, modifications or substitutions, under
normal and proper use shall not materially or adversely affect physical or functional
interchangeability or performance, except where there is written agreement between the
parties that specific characteristics will be so affected.
ARTICLE 23. LIMITATION OF LIABILITY
Except for personal injury or death, MOTOROLA's total liability whether for breach of
contract, warranty, negligence, strict liability in tort or otherwise, is limited to the price
of the particular products sold hereunder with respect to which losses or damages are
claimed. The CITY's sole remedy is to request MOTOROLA at MOTOROLA's option
to either refund the purchase price, repair or replace product(s) that are not as warranted.
IN NO EVENT WILL MOTOROLA BE LIABLE FOR ANY LOSS OF USE, LOSS OF
TIME, INCONVENIENCE, COMMERCIAL LOSS, LOST PROFITS OR SAVINGS
OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES TO THE FULL
EXTENT SUCH MAY BE DISCLAIMED BY LAW. No action shall be brought for
any breach of this contract more than one (1) year after the accrual of such cause of
action except for money due upon an open account.
ARTICLE 24. GLOSSARY
Term
Meaning
(a) Agreement This Agreement consists of the Articles herein, all Exhibits, and
Attachments or other parts of such Exhibits. It is the same as
"contract" when the context so indicates.
(b) Contract Written or printed Materials to be delivered at various points Deliverable
in time following Agreement award, such as Agreement Exhibits, or other
documents.
(c) Site A single, defined location containing radio, and/or microwave
41
(d) TRCS
equipment.
The entirety of the 800 MHz Trunked Radio Communications
System.
42
IN WITNESS WHEREOF, the parties hereto have caused this Agreement to be
executed by their duly authorized representatives as of the last day and year written below.
MOTOROLA COMMUNICATIONS &
ELECTRONICS, INC.
CITY OF SAN BERNARDINO
By:
By:
Tom Minor, Mayor
Name:
Title:
Date:
ATIEST:
By:
City Clerk
Approved as to form
and legal content:
JAMES F. PENMAN,
City Attorney
43
EXHIBIT A
STATEMENT OF WORK
STATEMENT OF WORK
THE DESIGN. IMPLEMENTATION. CUTOVER AND TESTING OF A
COMMUNICATIONS DISPATCH CENTER FOR
THE CITY OF SAN BERNARDINO. CALIFORNIA
November, 1993
Prepared by:
800 MHz Proiect
Transition Committee
[Technical Subcommittee]
Police/Fire/Communications
Management of Information Services
300 N 'D' Street
San Bernardino, CA 92418
TABLE OF CONTENTS
PAGE
1 INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. I-I
1.1 General Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. I-I
1.1.1 Specifications ................................ I-I
1.1.2 Quality of Work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. I-I
1.1.3 Implementation Schedule Startup Date ................. 1-2
1.1.4 Site Review and Definition ........................ 1-2
1.1.5 Site Preparation Development. . . . . . . . . . . . . . . . . . . . . .. 1-2
1.1. 6 Standards and Regulations . . . . . . . . . . . . . . . . . . . . . . . .. 1-3
1.2 San Bernardino/Motorola Project Focal Points. . . . . . . . . . . . . . . .. 1-3
1.3 Order Writeup/Edit .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-4
1.4 Motorola Responsibilities ............................. 1-5
1.4.1 Installations ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-5
1.4.2 Regulatory/FCC License .......................... 1-5
1.4.3 Service Parts ................................. 1-6
1.4.4 Shipped Equipment Receipt and Inventory ............... 1-6
1.5 City Responsibilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-6
1.5.1 Sites and Site Preparation . . . . . . . . . . . . . . . . . . . . . . . .. 1-6
1.6 Standards of Work. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-7
1.7 System and Equipment Layout .......................... 1-7
1.8 Turnkey System Implementation ......................... 1-8
1. 9 Radio Communications Coverage . . . . . . . . . . . . . . . . . . . . . . . .. 1-8
1.10 Acceptance Test Plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-8
1.11 Final Acceptance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 1-9
1.12 Warranty Commencement ..... . . . . . . . . . . . . . . . . . . . . . . .. 1-9
2 SYSTEM DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-1
2.1 Scope......................................... 2-1
2.1.1 History .................................... 2-1
2.1.2 System Configuration ........................... 2-3
2.1.3 System Implementation. . . . . . . . . . . . . . . . . . . . . . . . . .. 2-4
2.2 Scope of Work - Phase Two 2-6
2.2.1 Dispatch Center Consoles .. . . . . . . . . . . . . . . . . . . . . . .. 2-6
2.2.2 Electronics Backroom Equipment .................... 2-7
2.2.3 Base Stations, Repeaters, and Control Stations ............ 2-8
2.2.4 Interface to County CEB . . . . . . . . . . . . . . . . . . . . . . . . .. 2-8
2.3 Communication Links. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-8
2.4 System Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 2-9
2.5 System Drawings .................................. 2-9
3 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3-1
3.1 General........................................ 3-1
3. 1.1 Motorola Required Tasks ..................... 3-1
3.1.2 Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 3-2
3.1.3 System Optimization Tasks . . . . . . . . . . . . . . . . . . . . . . . .. 3-3
3.1.4 Implementation Supervision ........................ 3-4
4 TRAINING AND SYSTEM DOCUMENTATION ................. 4-1
4.1 General .......................................... 4-1
4.1.1 System Operator Training ......................... 4-1
4.1.2 Technical Support .............................. 4-1
4.1.3 System Maintenance Training ....................... 4-2
4.1.4 System Documentation ........................... 4-2
City of San Bel7U1rdino, Califv. aia - Statement of Work
1 INTRODUCTION
The quality implementation of the installation, configuration, acceptance testing, and
cutover of the City Dispatch Center (hereinafter referred to as CDq requires that the
parties involved clearly understand the precepts under which the project has been planned
and who maintains specific areas of responsibility.
1.1 General Requirements
This Statement of Work (SOW) which is Exhibit A of the Agreement between the City
of San Bernardino (City) and Motorola, Inc. (Motorola), hereinafter referred to as the
Agreement, defines the tasks and responsibilities of both parties with regard to the
turnkey implementation of a CDC as well as the supporting electronics backroom
equipment, and interconnection of remote operator positions to the County of San
Bernardino CEB. In any question of installation, criteria, or other intent regarding this
document and the specification, this document has precedence.
1.1.1 Specifications
Equipment and software specifications and system layouts are provided in this SOW and
included as attachments to the Agreement. These attachments provided by Motorola and
others, may be technical product sheets, special narratives, printed brochures or other
printed matter which clearly defines the technical parameters and describes the form, fit,
function, facility impact, power requirements and interface requirements of all the
equipment, software and subsystems comprising the CDC.
1.1.2 Quality of Work
All work shall be performed in a professional workmanship manner consistent with high
quality commercial practice and in accordance with Motorola's National Service
publication number R56, Quality Standards - FNE Installations. In all phases of the
work, Motorola will exercise the care and diligence that is associated with the design and
San Bel7U1rdino City Dispatch Center
1-1
City of San Bernardino. Calif/".. .ia - Statement of Work
implementation of the highest quality public safety communications systems.
Motorola will furnish all the necessary installation hardware, peripheral equipment,
fasteners, fixtures, cabling, connectors, and other equipment and procedures necessary
to install, cutover, and test the City Dispatch Center defined in this document.
1.1.3 Implementation Schedule Startup Date
Motorola will consider the official Notice to Proceed date as day one (I) of the project
implementation schedule.
1.1.4 Site Review and Definition
Motorola will conduct site surveys of the City Hall Dispatch Center, Transmitter Room,
Electronics Backroom and Rooftop with the City Project Manager and Communications
Maintenance personnel. The purpose of these surveys is to finalize system engineering
and equipment placement plans. These plans will indicate communications equipment
detail that apply to each specific site and reflect the final as-built documentation.
1.1.5 Site Preparation Development
Motorola will commence installation at City equipment rooms and Dispatch after
notification that all site preparation that is determined to be the responsibility of the City
has been completed. This is to include, but not limited to, City changes to the electrical,
air conditioning, backup generator, transfer panel, grounding, wall preparation, and
suspended ceiling modifications to the City Hall Penthouse Transmitter Equipment Room.
Motorola will commence installations at County sites after the City has obtained the
required lease agreement from the County and received the County's approval to proceed
with installation.
1.1.6 Standards and Regulations
San Bernardino City Dispatch Center
1-2
City of San Bernardino. Califv, ,La - Statement of Work
Equipment provided by Motorola shall meet or exceed the following publications and
standards. These documents shall be the current issue as of the date of this statement of
work.
FCC Rules and Regulations
FAA Part 77 Federal Aviation Regulations
Electronic Industries Association Standards
EIA-152 Minimum Standards for Land-Mobile Communication FM or PM
Transmitters
EIA-195 Electrical and Mechanical Characteristics for Terrestrial Microwave
Relay System Antennas and Passive Reflectors
EIA-204 Minimum Standards for Land-Mobile Communication FM or PM
Receivers
EIA-21O Terminating and Signalling Equipment for Microwave Communication
Systems
EIA-222 Structural Standards for Steel Antenna Towers and Antenna Supporting
Structures
EIA-232 Interface between data terminal equipment and data circuit-terminating
equipment employing serial binary data interchange
EIA-252 Standard Microwave Transmission Systems
EIA-31O Racks, Panels and Associated Equipment
EIA-329 Minimum Standard for Land Mobile Communications Antennas, Part
I - Base or Fixed Station Antennas, and PartIl, Vehicular Antennas
Where specified, radio equipment shall meet specific
requirements of parts of Military Standard 810
National Electrical Code
Local Electrical and Building Code
National Fire Protection Association (NFPA) #1221
FCC NPSPAC Docket Number 87-112
In the event of inconsistencies between this specification and the documents listed above,
the requirements of this statement of work shall take precedence over all but the
regulatory requirements listed above.
1.2 San Bernardino/Motorola Project Focal Points
Upon a notice to proceed, Motorola shall identify the proposed Motorola System
Program Manager to the City. The Program Manager shall have extensive field
experience in the implementation of like systems and the City will have final approval
of the candidate manager.
San Bernardino City Dispatch Center
]-3
City of San Bernardino. Califv. .€a - Statement of Work
The Motorola System Program Manager will be responsible for coordinating the activities
of all subcontractors of Motorola performing work on this project.
To ensure that the project progresses in an orderly and efficient manner, the City will
appoint a Project Manager to coordinate City Agencies' needs, manage the project
implementation and serve as a focal point of communications with Motorola's System
Program Manager.
The Motorola System Program Manager will schedule a formal monthly meeting with
the City Project Manager from date of Notice to Proceed until completion of system final
acceptance. Informal meetings to resolve project details will occur as often as required.
Project status reports will be submitted by Motorola on a monthly basis until project
completion. An updated schedule of events will be included in this report.
1.3 Order Writeup/Edit
Motorola will order the total equipment package based on the purchased equipment list
presented in Exhibit E. Minor modifications for connectors, cables, fasteners, and
miscellaneous small parts are acceptable and will be paid for by Motorola. The
equipment list is considered complete as proposed. Any changes to the equipment list or
design will be treated as a contract change order and affect both the schedule and the
price of the project. The equipment list is to be reviewed by the City, The
Communications Group, and Motorola only.
1.4 Motorola Responsibilities
1.4.1 Installations
Motorola shall coordinate with the City prior to installation at all sites. Motorola will
supply the equipment listed in Exhibit E, Purchased Equipment List, and all associated
San Bernardino City Dispatch Center
1-4
City of San Bernardino. Calif(" ,da - Statement of Work
software, cabling, connectors, and mounting hardware required to implement the fully
operational CDC described in this document. All system hardware and software will be
developed and manufactured at the respective Vendors facilities, and delivered by
Motorola.
Motorola will provide both the electrical and mechanical interfaces necessary to place
CDC supplied equipment into operation,
Motorola will provide and connect ground conductors from all applicable Motorola
supplied fixed equipment to ground points supplied by the City or County at each site.
All mechanical hardware relating to the installation will be supplied by Motorola.
All coaxial cable installed by Motorola will conform to the standards set forth in
Motorola's National Service publication number R56, Quality Standards - FNE
Installations,
All required control lines will be coordinated and provided by Motorola, Cable runs, in-
house will be implemented by Motorola except for those as provided by the City to
interconnect the City Hall Transmitter Room and the City Hall Basement Dispatch
Center. Existing conduit runs can be used, if space for the cable or cables exist.
1.4.2 Regulatory/FCC License
All equipment used in the system that will operate on the 800 MHz channels will be
designed and manufactured to meet or exceed the minimum technical standards required
for operation in the 800 MHz, 12.5 kHz offset environment and the NPSPAC
requirements,
1.4.3 Service Parts
Motorola shall guarantee that a complete stock or inventory of parts will be available in
the Southern California area to accommodate immediate repair or maintenance of system
components. Motorola shall also provide the location and telephone numbers of the parts
San Bernardino City Dispatch Center
1-5
City of San Bernardino, Calif(, .ta - Statement of Work
and service facilities available to accommodate local system maintenance.
1.4.4 Shipped Equipment Receipt and Inventory
Motorola System Program Management will advise the City of its requirements for a
warehouse of sufficient size and adequate security to accommodate the system equipment
prior to installation. Motorola Personnel will be provided to receive and inventory
equipment as required. Received equipment files will be available to the City for review
and will become a part of the as-built documentation.
1.5 City Responsibilities
1.5.1 Sites and Site Preparation
With regard to provision of equipment rooms, dispatch center, and supporting sites, the
City will provide the following:
a) The necessary space on designated structures and towers for Motorola supplied
and installed equipment including: antennas, transmission lines, mounting
hardware, grounding provisions, and filter equipment.
b) Sites and site characteristics as agreed upon with Motorola engineers to
accommodate system installation needs.
c) The designated space within buildings pursuant to plans which reflect the space
needs for Motorola supplied and installed communications and related equipment.
(d) The City will be responsible for environmental considerations (light, ventilation,
cleanliness, temperature and humidity) and general aesthetics within City provided
buildings and all remote sites. This does not apply to normal cleanup of
Motorola or Motorola subcontractor installation crews after work is performed.
(e) All cable access ways and necessary conduit runs shall be provided by the City
to meet the designed technical specifications and site plans developed by
agreement with Motorola.
(f) Relocation of, or removing equipment not installed by Motorola under this
contract. Drawings for existing equipment and interfaces not installed by
Motorola are the responsibility of the City. All existing equipment provided by
the City, such as electrical power distribution panels and generators are to be
operating and maintained to manufacturers specifications.
San Bernardino City Dispatch Center
]-6
City of San Bernardino. CalifL .ia - Statement of Work
(g) The AC power outlets at City Hall will be provided by the City and will be three-
prong grounded duplex receptacles providing 20 amp 115- V AC, 60 Hz circuits.
(h) The City will grant site access to Motorola and its sub-contractors during the
hours 8AM-5PM Monday through Friday, except for City holidays. Access
beyond these hours may be granted upon written request.
1.6 Standards of Work
All equipment provided for each site and the installation techniques used for that
equipment shall comply with the Uniform Building Code (UBC), Motorola Quality
Standard - FNE Installation, National Electric Code (1984 or later editions) and all other
applicable codes and ordinances, as they apply to the installation.
A system block diagram depicting the major system components is presented in Section
2.1, Figure 1 of this Statement of Work.
1. 7 System and Equipment Layout
The specific layout requirements of fixed-radio equipment within each facility will be
provided by Motorola utilizing an equipment rack mounting approach, on a site by site
basis. These equipment layout drawings shall detail the power capacity and circuit
requirements on a per rack basis. Individual drawings shall be provided for the City Hall
Transmitter Room and City Dispatch Center.
1.8 Turnkey System Implementation
Turnkey system implementation is required and includes system engineering, equipment
manufacture, equipment delivery and installation, system integration, vendor project
management, and performance verification.
1.9 Radio Communications Coverage
As the City Dispatch Center will be operating base stations on existing VHFIUHF
frequencies, the County of San Bernardino's 800 MHz trunked system, as well as the
Little Sunset 800 MHz trunked single site system; and, as the performance of these
systems are known from previous years of use and current testing of the systems during
the testing phase of the Little Sunset trunked system -- the radio system coverage
San Bernardino City Dispatch Center
1-7
City of San Bernardino, CaliF. .lia - Statement of Work
performance or performance guarantees will not be a part of this document.
Consequently, the City will not require that Motorola assume any responsibility for
coverage performance.
1.10 Acceptance Test Plan
The Acceptance Test Plan (A TP) shall be a composite of individual test plans which
specify the test procedure to ensure Motorola's compliance with installation requirements
and system performance in several categories. These categories are:
I) Physical installation at all locations.
2) Electrical specifications of supplied equipment
3) CEB and Console functionality
4) System level adjustments and level measurements
Motorola shall accept responsibility for all items purchased under this contract.
Acceptance by the City will be with one signature per individual test plan. In the event
of non-compliance (non-acceptance) of items associated with a particular test plan,
Motorola will correct all such items prior to demonstrating compliance and requesting
the City sign-off on that particular test plan.
1.11 Final Acceptance
Upon completion of steps outlined in the Acceptance Test Plan (A TP) the system will be
considered complete and conditionally accepted, and a document will be signed by the
City to acknowledge this. Final acceptance will be signed after conditional acceptance,
and when all punch list items have been completed.
1.12 Warranty Commencement
Motorola will warrant all of the CDC equipment furnished and installed for a period of
four (4) months, parts and labor. After four months Motorola will continue to warrant
the CDC equipment for an additional eight (8) months, parts only. The Motorola
warranty will be considered in effect and in force, starting day one after final system
San Bernardino City Dispatch Center
1-8
City of San Bernardino. Calif" .ia - Statement of Work
acceptance. Optional costs are provided in the purchased equipment list for warranty
labor to complement the additional nine month equipment warranty period as well as
second and third year warranty maintenance, parts and labor. The Motorola warranty will
be considered in effect and in force starting day one after final system acceptance or on
the first day of beneficial use as detailed in Article 5 of the Agreement, System
Performance And Acceptance Testing.
San Bernardino City Dispatch Center
1-9
City of San Bernardino, Cali./t-,da - Statement of Work
2 SYSTEM DESCRIPTION
2.1 Scope
The scope of this Statement of Work is to include only the Phase Two portion of the
City's migration to 800 MHz, and reconfiguration of its Communications Dispatch
Center as described under Section 2.1.3, and detailed in Section 2.2 of this document.
2.1.1 History
Current directives by the Federal Communications Commission (FCC) have placed
tighter equipment and spectrum standards on the radio equipment that will be allowed for
use by spectrum users over the next five years through the turn of the century. The
directive is generally referred to as the 'Refarming of the Radio Spectrum.' This
refarming will allow more radio channels within the same radio spectrum and,
consequently, more users. This action will require that the radio equipment be more
stable, and occupy a narrower radio bandwidth. These requirements will force the
replacement of existing equipment and frequencies for today's radio communication
users. Indeed, the requirements by the FCC are driving a major communications
revolution in the public safety and city government services.
The City of San Bernardino currently uses VHF and UHF frequencies for their police,
fire, and local government users. In the very near future, the city will be required to
replace and update its radio inventory, or migrate to the newer 800 MHz radio channels
that fall outside the FCC's refarming directive. The City of San Bernardino has elected
to move its radio services to the 800 MHz radio channels. A prime consideration during
the migration to 800 MHz is the provision for improved communications security,
functionality, and interoperability with the surrounding cities and agencies.
The standard for compatibility in the San Bernardino valley is the Motorola Smartnet II
trunking environment. This system is in use by the County of San Bernardino, many
agencies as users of the County system, as well as the west San Bernardino valley cities,
WECA, a Joint Powers Authority. The benefits of maintaining absolute compatibility
among neighbor agencies are numerous, and the resulting improvement to the public
safety is substantial.
San Bernardino City Dispatch Center
2-1
City of San Bernardino, Calif, .ia - Statement of Work
The City of San Bernardino is preparing to transition from the use of VHF and UHF
radio frequencies to 800 MHz. The proven performance of the Motorola Smartnet II
trunking system and the compatibility with the agencies surrounding the City of San
Bernardino has driven the decision to implement the new city communications system as
a Smartnet II system.
A group of frequencies that have been licensed by the County of San Bernardino are
candidate frequencies for use by the City. Because these frequencies have been idle for
a long period, and because of the shortage of radio spectrum, the City cannot be assured
that the frequencies are 'interference free.' Consequently, to eliminate the possibility of
constructing a costly radio system on a set of frequencies that may be potentially
unusable, the city has accepted an offer from the County of San Bernardino and
Motorola. The city will work in concert with the County to test and load these
frequencies. The results of the testing will determine whether the frequencies are usable
for public safety purposes. If the frequencies are 'interference free', the City will
ultimately purchase the constructed test system as its' own Smartnet II trunked system.
If, instead, the frequencies are inadequate, the city will migrate to 800 MHz as a system
user on the County's 800 MHz Valley system.
The city has chosen to implement the transition to 800 MHz as a 'city driven' rather than
a 'vendor driven' project. It is important to note that the County of San Bernardino has
constructed the largest 800 MHz radio system in the United States today. The
considerable expertise and resources available from the County of San Bernardino's 800
MHz project and management group will allow the City to build a radio system that will
not require the extensive costs typical of vendor-driven projects. Consequently, project
management and engineering costs can be kept to a minimum. Specifically, the City will
direct the vendor to provide only those engineering and implementation services that are
required to implement and cutover the existing VHF/UHF radio system to 800 MHz.
2.1.2 System Configuration
The new 800 MHz radio system will service the communications needs of the police,
fire, and (in the future) the local government users. All city radios will be programmed
San Bernardino City Dispatch Center
2-2
City of San Bernardino. Calijc .ia - Statement of Work
with mutually agreed talk-group combinations, allowing the controlled separation of users
based upon communications needs. The older VHF and UHF frequencies will be
replaced with a trunked system of radio transmitters allowing more efficient user of radio
spectrum, and reduced channel congestion.
The city 800 MHz radio system will consist of:
a trunked radio system,
a city dispatch infrastructure, and
a city owned inventory of portable and mobile radios.
The trunked radio system will be either city-owned, or contracted by Use Agreement
from the County of San Bernardino. The actual configuration will be determined after
extensive testing of a ten-channel trunked system that is currently being constructed at
the Little Sunset radio site. This testing is part of the Phase-one portion of the city's
migration to 800 MHz. If the tests realize a set of useable frequencies for the trunked
system that are free from radio interference, the city will purchase the system. If,
instead, it is determined that the frequencies are not useable, the city will contract
services on the County 800 MHz system.
The City's dispatch infrastructure will consist of the dispatch center, currently located
in the basement of the City Hall, as well as the backbone electronic support equipment
located in the basement and the penthouse of the City Hall.
The second phase of the city's radio restructuring will include the updating of the
dispatch center to support the 800 MHz trunked backbone. This will encompass the
relocation of the dispatch support equipment to the penthouse, thereby providing for a
secure and centralized electronics backroom. Because of the anticipated relocation of the
police and fire dispatch centers in the near future, this centralization will allow the police
and fire dispatch centers to move with minimum inconvenience, and maximum system
stability and security.
The city owned inventory of portable and mobile radios will provide 800 MHz service
for the police and fire agencies. The portable radios were purchased during the third
quarter of 1993. The mobile radios will be purchased during the last quarter of 1993,
San Bernardino City Dispatch Center
2-3
City of San Bernardino. Cali.Jc. .lia - Statement of Work
as part of the Phase-one portion of the migration.
The new communications system will have allowed the city to migrate from the older
VHF and UHF radio channels to a trunked 800 MHz radio system, with the retention of
a couple of the VHF and UHF radio channels in order to maintain compatibility for state
wide communications, as well as the original local government radio channel. The
migration of the local government communications to 800 MHz is not scheduled for a
couple of years, but the basic infrastructure will be firmly in place at the time of
transition.
2.1.3 System Implementation
The City will be using a three-phase approach to stage and construct the City's new
communication system:
2.1.3.1 Phase One
The first phase of the 800 MHz police and fire radio project will include the
purchase, programming, and installation of mobiles for the City's fire and police
departments; as well as a commitment to the County by the City to operate a
limited number of City radios, as a county user, on the County 800 MHz system
for a minimum of three months to allow for interference testing on Little Sunset,
coverage testing and comparison of the valley system with Little Sunset, and the
migration of the City dispatch center to 800 MHz.
The implementation of the Little Sunset trunking system by the County of San
Bernardino 800 MHz group, with the cooperative assistance of Motorola for the
purpose of testing the proposed 800 MHz channels for their suitability as 'public
safety quality' communications frequencies will proceed in parallel with Phase
One, and should be considered as part of Phase One.
The preparation and design of the City's dispatch facility will proceed in parallel
with Phase One.
San Bernardino City Dispatch Center
2-4
City of San Bernardino, Calil~ da - Statement of Work
Several issues were considered during the concept stage of the dispatch center:
The police department is expected to move its dispatch center to the new
police facility in the near future, and vacating the City Hall dispatch
center.
The relocation of the dispatch facilities in the City Hall basement would
leave the electronics backroom equipment in an unsecured location.
Relocation of the dispatch electronics backroom from the City Hall
basement to the City Hall penthouse will provide for increase security, as
well as conditioned environmental and electrical space.
A major earthquake or water spill would render the City Hall basement
unusable.
The final design of the dispatch center will result in an order for equipment and
services from Motorola to implement and cutover the dispatch center to provide
for interoperability with the County 800 MHz radio system, as well as full
operation of the City's 800 MHz radio system. The determination of whether the
City will operate its 800 MHz radio system as part of the County 800 MHz
backbone or as a City-owned tronking facility at Little Sunset will be determined
based on the results of the interference testing of the frequencies at Little Sunset.
2.1.3.2 Phase Two
The second phase of the City's 800 MHz migration plan will constitute the
implementation and cutover of the City dispatch facility. The final configuration
having been determined by the results of the interference testing.
2.1.3.3 Phase Three
The third and last phase of the City's 800 migration plan will include the
purchase of all final equipment to implement the migration. If the interference
testing is able to identify that the selected frequencies at Little Sunset are suitable,
the City will purchase the radio system from Motorola. If, on the other hand, the
interference testing results in an unusable system for public safety purposes, the
City will finalize negotiations with the County to operate as a user on the County
800 MHz radio system. The test system at Little Sunset will then be reconfigured
by the County for non public safety uses, i.e. local government and support
services.
San Bernardino City Dispatch Center
2-5
City of San Be17UJrdino. Calif'- ia - Statement of Work
2.2 Scope of Work - Phase Two
The City of San Bernardino desires that Motorola provide all system equipment, designs,
and integration of a turnkey reconfiguration of the City's Dispatch subsystems per
Section I. 8 of this document.
The basic City Dispatch subsystem components include:
Dispatch Center Consoles
Electronics Backroom Equipment (i.e. CEBs)
VHF/UHF/800 Base Stations and Control Stations
Interface to Microwave Systems
Interface to County CEB from City Remote Operators.
2.2.1 Dispatch Center Consoles
The CDC will include nine Police dispatch positions (seven operational consoles and two
desktop consoles for the center's training console), and four phone positions (three that
are being added under this project as part of a State sponsored telephone upgrade).
There will also be three Fire dispatch Positions. The placement of the dispatch consoles
is detailed in Section 2.5, System Drawings.
If the City purchases the Little Sunset trunked system, one Fire dispatch console and one
Police dispatch console will be configured as a remote operator position connected to the
County of San Bernardino CEB in Rialto. The remaining dispatch positions will operate
as remote operator position on the City's own CEB, that will be relocated from the City
Hall basement to the City Hall roof penthouse.
If the City transitions to the County of San Bernardino trunked system, one Fire dispatch
console and three Police dispatch consoles will be configured as remote operator
positions on the County trunked system. All other consoles will operate as remote "RF"
control dispatch consoles.
The console positions will be migrating from CentracomII Plus button positions to CRT
positions, with reconfiguration of existing console equipment to provide for new CAD
San Be17UJrdino City Dispatch Center
2-6
City of San Bernardino, Calijc .ia - Statement of Work
CRT equipment.
2.2.2 Electronics Backroom Equipment
The current City CEB is located in the basement of City Hall. The CEB is comprised
of five card cages and three power supplies that are configured as two separate CEBS --
one for Fire, one for Police. A cutover plan will provide for the relocation,
reconfiguration, and expansion of the existing CEB.
The new CEB will be located at the roof penthouse of City Hall. It will be co-located
with the VHFIUHF/800 control and base stations, as well as the existing 2 GHz, 18
GHz, and 23 GHz microwave stations.
The new CEB will include ten card cages, seven power supplies, three modem card
cages. The CEB will control the VHFIUHF/800 control stations located in the
penthouse, and primary VHF/UHF base stations located at Little Mountain via
microwave.
The new CEB will be designed to support a maximum of nine dispatch positions, room
for possible future control of the lO-channel Little Sunset trunked system via the system's
secondary controller port, all of the existing VHF/UHF main/backup base stations, and
audio delogging from the CEB's BlMs.
2.2.3 Base Stations, Repeaters, and Control Stations
The existing VHFIUHF base stations are located in the penthouse of the City Hall, and
at Little Mountain.
Eighteen new 800 MHz control stations will be rack mounted and installed in the City
Hall penthouse. These control stations are to be configured as RF control stations, as
well as providing detrunked audio to the Fire and Police voice logging equipment.
San Bernardino City Dispatch Center
2-7
City of San Bernardino. Cal~_ nia - Statement of Work
2.2.4 Interface to County CEB
Two of the CDC consoles will be configured as remote operator positions on the
County's Valley Trunk System. Motorola will provide the hardware and integration to
couple the two CDC consoles via the City's 18 GHz microwave to Little Mountain. The
City will lease County microwave circuits to connect from Little Mountain to the Rialto
backroom CEB.
2.3 Communication Links
The CDC system components are connected by a combination of hard wire cabling and
microwave circuits.
The microwave circuits consist of an City owned 18 GHz digital microwave system, a
City owned 2 GHz microwave system, and the existing County-owned digital microwave
network.
Twisted pairs shall be delivered and installed between Motorola provided punch blocks
and Motorola provided equipment at the penthouse. The City will provide a lOO-pair
cable from the penthouse to the Dispatch Center.
2.4 System Warranty
System warranty is addressed in Section 7 of the Warranty and Maintenance Agreement.
Motorola will provide a one (1) year warranty of all equipment supplied with this system
from the date of final system acceptance. The one year parts warranty shall be
accompanied by a Motorola four (4) month labor warranty and an optional cost for the
remaining eight months.
Motorola shall also provide an optional cost for second and third year warranty
maintenance. The maintenance requirements and conditions shall be identical to the
warranty period maintenance provided during the first year after system acceptance.
San Bernardino City Dispatch Center
2-8
City of San Bernardino, Calift.. . ria - Statement of Work
2.5 System Drawings
San Bernardino City Dispatch Center
2-9
-en
C)
D Ci
Ci. C)
'!:!
> ill
C) '" '" "" Ci \..)
D C) C) C) ill 5'
'" Ci.
Ci. Ci. D D ::J ""
Ci. Ci. en ill
en
~
ITl
". ~~III
,-/- U
~ --~
II
"
1L.
,I
I
'I
L
G
G
'"
~
"
~ /)1-
'"
<0
D l:
I z
II ctE
~~~ "z
i ' z2
cI.J.....e:.:
",,~
"''''~
, ~~Z
c La.~
~ "~ ~G"
'" %~
~ . ill
G ~~
~~
~~:
l~~
" .--
. .
:~:
G
:;
~ ~ I1ilr\
~-~~
~ I a a !
L-nU
u
I
,
"
,
'0 -
b~ ~ .
u '1"' <f~ I
~ . ~~ i
~ ~:! ~~ ~
i ~; ~~
~, '"IC
,dg <'
"II 1'1
g
~
Z
T
G:
en
Z
o
;:
<
"
0>
"
Ii:
z
o
w
....
'"
"
"
0>
....
'"
~
o
en
Z
o i
w
~
<
>
o
"
..
~ i
i
i
~
'"
;;
z
:l
..
I
....
0>
o
,..
:l
'"
~
o
en
Z
o
W
:!:
W
....
<
..
en
i5
"
'"
....
Z
'"
W
en
Z
o
;:
<
W
Z
0>
'"
'"
o
w
I!
II.
! "
d
h
v '_
I
I
L
..J...
~h
~i>I~ ~,!! _
! !;
"
:~
n;l
, t'~h5;5
~H~~~]~~~
i!: ~i!:!Iiol,! r
i!: ~
~H!
!!llll !!!
II"i'li!
"l!.! ..
!
l
!
Illl!
iijj
.. .
i
, 11111
! j !llI1hHI.i5j
'J...,,"....]~} .
: ::H: :~~l
. ~~r~
, .
l ~
: I q ..
. "I I'.
. jJ .! If I ; i ~,tJ.
; 1!'! !:,Illlhull
i ~ ~ '"{ ~,q'\:::~~
~ <> :5 !jg.d::u....
~;; ~il ,,;c ~"
I
~ .l
Hl
H
~il
I Ill.
i ~. Ii
~ tt~!
1 g~E~
~\ \
1 ~ J
r ~ ~ '-I~.......//
I \Lf?~~l...i, \
~.<T7uvl \ ~
?i~ ; / 'w ': ~
~ '.1 \/ C ;J'
: i" ; j
""1 ..~ ~1I
\S.~L ..~...;. (
~ /J\
l?l N ~~
( /~
t/
,
.
/!
ig~
~e ~ ~~~I
c' I h.
.~~! m
" !&: iH
~~~ :~~
...,
~ ; ~
&. 5 ~
0.. :;; "-
;;:g :;~;.. -
~~ 1~ 1~ !
~ l! iO !
~~~;>' .E".-
1:: 0( ~.... );
:'Pia '^~ "':; ..
.", · , i
3~! I! 8
~I i ~
~_I 00
L
,
.
.
,
I ~
,.
J .
-
I
i "
.1
$I
"
i ;, i
-'
'"
~
:ij
0.
0.
'"
.
I
. ! i
1J..... I
~l
OJ
;:
'"
OJ
~
o
OJ
f-
in
'"
z
'"
I
"
OJ
f-
(f)
>-
(f)
o
i5
'"
0:
I
..J
'..J '_
~
-r
'1-
-.
'~
:~
'L
I
,
,
~
.
INO/!JL
'.1s
I~t~~
B
"1,."".""1""",.,,.1,,
",I.."
.",tI""""",I"""",I,.
, "1111111111111111111111111111111111111111111111
i i i i
i Ii ~ ~ !! ~
" ~ " ..
, ,
:.,
J-
}-
iL
--- Ii
!
. .
, .
.' l'
01. w
1'- ,
wo .---
; I
! ~ .l! ! ! 1
w !'l;
~: ~: ..
~; w.
I ""I,,,,,,,,
",I" """I ,,,1,,,,,,,,,,,1,,,,,,,,,,,,,,,,
"""I.
'1111111111111111111111111.'
"!IIIII"III"II!III.
Ii .. ;;:
~
[f)
'"
"'
'-'
'-'
0
....l
"'
"
[f)
z
0
;::
.."
f-
[f)
....l
0
'"
f-
Z
0
U
N
:I:
::;
I
0
0
co
-'<l
'"'
, :I:
0
'"'
:I:
>-
I
~
11
I
UJI
-,
"<1
;oJ,
"
o
::;
-'<l
[f)
'"
Z
.."
00
u
~i
'"
~
u
"'
....l
"'
....l
~I
~I
~II
>
g~ ~
"8 . ~
~~ ~; ~~
~ H a~
" ~. U
~ ,.."
a; ~
",
2
I "
:1
, .
i .
...
'"
>
0
'"
.. i
..
'"
i !
I-
,
, .
B
s
P
d-
~
-
.
-
I
,
1
I I
, ,
~
,
,
1
.
9. _ ~ ~
- ~ . ~
~ ~g ~ ~o
. OU
Z ~~ ~ 1E~
o 1Il0. '" ..,51
U ~~ ~ is
j 8~ ~~ ~ ~;;:
'" "'0 ~~
" ~5 ::i ~ ~~
5 ~~ i5:' ~ ~~
~Q.;i8~o~z~
~~~~~8:~l~
8 ~- .;:) S'''' "''''
;gg!~88~z
>- 0 ~~ "'~ ~~ ii~
~~ i~ ~i ~~ ~~
H~: [~i~ o:~
:@.. ..~ _~..o::~
~~ ~~ ~~ ~~ 8!
u>-M9~~-"
~~ ~~ ~g ~~ ~~
r!
, '.'
'2
~~
I
r--
j
;
.
~
,
!
!
r
i
I
I:.'
, 0
I ,
I'I~
f'
.
U
o
o
,
,
o
c
r
.
:J
" ]
[JiJ
> m,
, ~ <i
i' \.Q ~
o
~
u
,
~
r!I~1
'"
2
a
c ~K B
<<
~
'"
:!if
<<
ID
I
'"
ill
OJ
<i
-~/
'"
~ ~
" <i
.
"
"
ill
>
-ill<<
;;:~
~
G
I
U~
"''''
",.
1
T 1
~ ~
T
/
~
'"
a
<i
<i
:0
'"
m I
ID
ill
U
I "
J
/
ill
:> z~"
<( o<<z
~ ~~~
- '"-~~
I ~~~
~ ~I(~t ~
'"
I
I
""
""
I
1
""
"0
I
,::'1
i"l'
'"
I
....
:0
o
,..
j
....
Z
'"
'"
'"
S
a
'"
~ , '
g. , ~ .
l;;~ a ;
~. t2 ~r !
~~.J~~! c
...~ ~i rt
H~H~ ,
.. >8 "
"l G~
g
.
,
I-
i
I
~
-;"
,
q
l a ~
f-
I "
.1
:.
...
..
...
o
0:
..
..
..
'"
o
o
0:
....
Z.
'"
'"
'"
:0
a
'"
-
I
,
0:
o
o
...
""
e:
z
'"
;.
'"
'"
f-
'"
o
o
0:
0:
'"
....
....
;;
'"
z
..
0:
....
r
T
<~
,
I ..
I '"
;;
I ....
I Z
I 0
c:
I ..
I ,
I ~
I I '"
I Z
1 '"
I "
1 .,
u
I I 0
I c:
.,
I u
'"
'"
u
I
I 1
I
I I
I 1
I
I' I
B:
~
~
....
Z
o
c:
..
,
'"
'"
Z
'"
"
.,
u
o
c:
.,
u
'"
'"
u
ii,
. .
,..~ :;;
~::: ;. ....
11'" t!il i
~~ U ~i
~~~. ~~
'" ,.... u..
J"~ !
" ~ "
E u .
2
~
"
I!
~
.
I
.
1 .
I 1 ;
I
I I
1 I
I I ,
I "
I I 0
I Z
I '"
I "
I ., ,
u
I .
I 0
c: ...
I ., .,
1 u >
0
" c:
'" ..
u ..
.,
I !
1 ..
I '"
I ;;
I ....
I z
1 0
c:
I ..
I ,
I '"
I 1 '"
I ZI
I I gl
I I
I 0
I c:
.,
I u
"
'"
u
~ I I ~
I I ;:!
I ....
I Z
I 0
c:
I ..
I ,
I ~
I 1 '"
I Z
I '"
II "
I .,
~f u
i 0
0:
I .,
1 u
"
:::1
I I ..
I '"
I ;;
I ....
I Z
I 0
0:
'I ..
I ,
I M
I I '"
I z
I '"
I "
I .,
u
I I 0
I c:
.,
I u
"
'"
u
1 I ..
1 '"
I ;;
1 ....
I Z
I 0
c:
I ..
I ,
I N
1 I '"
I z
I '"
I "
I .,
u
I I oi
I ~I
:
I I ..
I '"
I ;;
I ....
I z
I 0
0:
: ..
I ,
II -
I '"
I I Z
I '"
I "
I .,
u
1:0 II 0
c:
.,
j u
"
I '"
u
I
"-
City of San Bel7Ulrdino. Calij. .lia - Statement of Work
3 INSTALLATION AND MAINTENANCE
3.1 General
Motorola will perform all work and tasks required to engineer, furnish, install and
optimize City's CDC described by this Statement of Work.
Motorola shall provide the name and location of the Motorola Service Shop (MSS) which
will perform the warranty maintenance for this project.
Motorola shall install all system firmware and software required for operation of the
CDC.
All equipment furnished for this system will meet or exceed all FCC requirements, the
technical requirements delineated by the Agreement and this Statement of Work and will
be designed, manufactured, installed, tested and adjusted (including Programming) with
the care and diligence generally applied to highly reliable public safety communications
systems. Refer to Exhibit A of the Statement of Work and to Exhibit G of the
Agreement (Motorola FNE Installation Quality Standards).
Equipment provided by Motorola will be grounded to an existing ground system
(furnished by others) within the buildings and within ten (10) feet of equipment
cabinet/racks.
3.1.1 Motorola Required Tasks
Motorola shall provide the following tasks:
a) Delivery of all system equipment, materials, and supplies to their intermediate
and final locations.
b) The provision of all qualified personnel to conduct the work, including warehouse
personnel, if required, at no additional cost.
c) Provision of all tools and test equipment to install and optimize the system.
d) Programming of all Motorola CEBs and Dispatch Terminals.
e) On-site installation of all fixed equipment.
f) On-site optimization/integration of all defined sub-systems and major components.
g) On-site electrical and mechanical checkouts of the complete system.
h) Installation Supervision-Vendor Project Management.
i) Submission of equipment manuals and actual as-built system drawings.
San Bernardino City Dispatch Center
3-1
City of San Bernardino, Cali.J_. nia - Statement of Work
j) Performance verification tests and compliance as described in Section 1.13,
Acceptance Test Plan, and Article 7 of the Agreement, Warranty And
Maintenance.
k) On-site Training of operators and technicians as described in Section 4.0,
Training And System Documentation.
I) Warranty period maintenance as described in Article 7 of the Agreement,
Warranty And Maintenance.
All applicable work and procedures shall conform to the standards set forth in Motorola
National Service publication number R56, Quality Standards - FNE Installations.
3.1.2 Conditions
Motorola will commence work at a respective site only after the City has notified
Motorola to proceed with the work at that site.
Equipment provided by Motorola for the CDC will be installed only once by Motorola
with the following exceptions.
a) Removals and installations because of equipment failure of malfunction, prior to
system acceptance.
b) Removals and installations to facilitate trouble shooting and malfunction
investigation.
c) Removal and installations to upgrade equipment or software.
Should Motorola or the City require additional time or materials (such as system
implementation delay or additional materials/equipment needed to complete system
phase), this requirement shall be made in writing within 15 calendar days of discovery.
The communication shall be in the form of a change order, indicating type of change,
potential costs and/or delays and impact if any on the overall project. Motorola or the
City will be required to reply with either approval or further information requests within
15 days of written change order request. Upon approval, the change order shall be
added as an amendment to contract.
The City will provide the necessary buildings, space within buildings and structures
capable of supporting the new equipment assigned to each location. If Motorola finds
otherwise, it will notify the City within 24-hours of the finding.
San Bernardino City Dispatch Center
3-2
City of San Bernardino, Califc da - Statement of Work
All work is planned to be performed between the hours of 8AM-5PM Monday through
Friday, except for Holidays. If work beyond these hours is REQUIRED by Motorola to
meet schedules or otherwise, Motorola will notify the City in writing prior to the
beginning of such work.
Motorola and its subcontractors will coordinate with the City all site access requirements
48-hours prior to commencing work at each site.
Motorola will use care, diligence and City/County direction in placing and configuring
all site equipment to provide the most efficient site installation. The City and/or County
will delineate which equipment locations and facility space can be used by Motorola.
Motorola must configure and install the Motorola furnished equipment (cabinets and or
racks) within the designated space.
3.1.3 System Optimization Tasks
The term optimized will be used to define the desired final status of a local site. As-built
system documentation shall be provided for each site where fixed equipment is placed.
System optimization will include the following tasks:
a) Install any required hardware and/or software modifications as per final design
review.
b) Install ,verify, and document all required board jumpers as required.
c) Verify and document the proper configuration and interconnection of all site
components and interfaces.
d) Verify and document the proper performance of all microwave circuits.
e) Test all spare boards, if provided. Motorola will provide a list of recommended
spare parts and their associated cost in the optional costs section of Exhibit E of
the Agreement, Purchased Equipment List.
1) Verify local AC and DC power conforms to minimum performance requirements
of all equipments.
g) Adjust and document all local DC, Data and RF levels in accordance with the
supplied system block and level diagrams.
h) Adjust and document all end-to-end signal levels, per manual.
i) Test and document antenna systems VSWR.
3.1.4 Implementation Supervision
San Bernardino City Dispatch Center
3-3
City of San Bernardino, Calljlia - Statement of Work
To directly support the Motorola System Program Manager, one or more Installation
Supervisors will be assigned to coordinate, manage, and direct the implementation stage
of the project. The Installation Supervisor will provide on-site supervision to Motorola
and sub-contractor installation personnel during the entire system implementation process.
Specifically, the Installation Supervisor will be responsible for:
a) Assisting the Motorola System Program Manager and the City Project Manager
in developing the Final System Implementation Plan.
b) Performing inventory of all shipped equipment to ensure complete delivery.
c) Inspecting the physical condition of all hardware to ensure that none has been
damaged during shipment.
d) Direct supervision of the field implementation teams, ensuring all on-site
installation and optimization tasks are performed within contract requirements and
project engineering specifications, and that Motorola's high quality standards are
met.
e) Verifying customer sign-off acceptance for the completion of each planned phase
and installation of each site.
f) Verifying that the system has been properly optimized and is ready for acceptance
testing.
g) Advising System Program Manager appraised of current project implementation
status.
h) Participating in customer meetings with the System Program Manager as
required.
i) Participating in the training of City operator and maintenance personnel.
j) Participating in sub-system internal and external acceptance testing.
San Bernardino City Dispatch Center
3-4
City of San Bernardino. Cali}~ .lia - Statement of Work
4 TRAINING AND SYSTEM DOCUMENTATION
4.1 General
Motorola will provide on-site training services for operational and communications
maintenance personnel as described below.
4.1.1 System Operator Training
Concurrent with the installation and prior to the performance period of the CDC,
Motorola will provide on-site orientation and training for the City's dispatch operator
personnel as to all aspects of system operation and functionality. Personnel shall be
trained in all available routine features and functions.
The City shall have the right to videotape all training at its expense to provide a
permanent training record and system operations record. Motorola shall provide all
training materials and supplies. Copies of any and all training material shall become the
property of the City. The training sessions shall be scheduled at times and locations
convenient to the City.
The City will provide space where training can be conducted. Operating equipment to
be used in a "hands-on" environment, as well as all supporting equipment, shall be
supplied by Motorola.
The training seminars shall include but not be limited to the following:
. Distribution of training literature, including operational manuals.
. A presentation of the general communications equipment/system theory,
configuration and features.
. A description of communications procedures, features and functions with
demonstrations and hands-on participation.
. A question and answer session.
. Operational troubleshooting of the equipment.
4.1.2 Technical Support
Throughout the warranty period, the contractor shall maintain a technical support
department where Motorola trained City personnel can call to resolve questions regarding
the operation of the dispatch equipment and supporting dispatch infrastructure.
4.1.3 System Maintenance Training
OMNICOM, Inc.
4-]
City of San Bernardino, Cal!J~ . tia - Statement of Work
Concurrent with the installation and prior to the performance period of the City Dispatch
Center system, Motorola shall provide on-site orientation and training for the City's
communications maintenance personnel as to all aspects of the operation, functioning,
troubleshooting, and periodic maintenance requirements of the new CDC.
Motorola shall provide training manuals, materials, etc. and training personnel
experienced with the CDC system components as well as:
. Distribution of training literature, including operational manuals
. A presentation of the general communications equipment/system theory,
configuration and features
. A description of routine communications procedures, features, and
functions with demonstrations and hands-on participation
. A question and answer session
. Troubleshooting to the equipment component level, utilizing Purchaser's
test equipment.
4.1.4 System Documentation
The following documentation will be provided by Motorola for the system:
a) Equipment inventory documentation including serial numbers and final
mode/channel configuration.
b) Site inspection documentation.
c) Equipment performance documentation.
d) Customer sign-off of each completed phase and installation on a per-site basis.
e) A hardcopy of all "as-built" system documentation and a copy on diskette.
f) Acceptance test data.
OMNICOM, Inc.
4-2
EXHmIT B
IMPLEMENTATION SCHEDULE
(Deliverable After Contract Signing)
EXHmIT C
MILESTONES AND SYSTEM PAYMENT SCHEDULE
(Deliverable After Contract Signing)
EXHIBIT D
ADD AND DELETE SCHEDULE
(Deliverable After Contract Signing)
EXHffiIT E
PURCHASED EQUIPMENT LIST
>-
-
(J
-
'"
0
U
-
C
:::>
0
c c
'ti 0
5'5
Ee-
CD 0 CD
1Il_", Z
C C C 0
c-.c
'" Clll.. 5:
_ c
0'0 12
>-0;:: ~
:t:1L
U UJ
0
--'
",UJ
1110
....0
~~
:r::
III
>
III
~~
....UJ
o!:::
Il..
"0
Ol
"0
C
Ol
><
UJ
S88S888~8888i:
oddc.-)ddd~da:)a:icia:i
-<I'><hCOC"')('I")<J),....,,<.t>NN<J>CO
.- C"')NN l() L,{)l.() It)
l{') 000 Lri <J)<f> N
co C"')-- N o,Q
N (f)<J)<f) <J) C"')
<J> <I>
l.()L,{)I.OLl)Ll)L()L()
t{)L,{)U')LOl()L()Ll)COC:OCOcoco
-------
~88~888~8888
O:oo<i<i<io"o<i<io
C")(J')(J)Oo-o-O(J')o.<r>-o-o(J')
co - (/) (f) <I'> <n
. (/)
<J>
C")
(/)
o
C '5c C
000 0
C +=0 e:::=+= ~Ol
o "g"
:> UOl :>:;-
0. Q) Q)cnC
Ol 0 ~ 0l~00. 0.2'0
=tI) \/UU)() ~gt-;"
.0:: _c>-:: -UJ.o
000- OlQ)UO Q)_~
~5:'55Q)~~.E5:0l~.2!'"
"I{)::J 0 00.. 001{) 00..0
U':~~CQ)E~-:CQ)Q)
ON::Q)O>CONo>,>
.....I o-c::::;:: o>....:r:~:;::>
t;~,> 0 '" o.:;:t;~ '" 0.-",
Q)8>EC$o-E0l8C$oU
0. OQ)-"O 0. -"00
enc:o-~U~Oenc:oU~ai
0..0.. 0..0..
OOCf) Cf)U)
~~ ~~
~5:N-o~g ~5:~g
"""oC"')o.ococou Oa:>l.{)
g8~~3~~~~3~3
_O.oU"oQ)-NO.oU"O
------ NNNN
~88~888~88888~8
<ioo<i<i<io<ioo<i<io"o
-(/)<I)C"')OQ(J')C"')(/)<J)O-Oo(J')o.<.r>
..q 0"""'''''''' 0 C"')l:").-
u) cO N N . (/) <I) cr)
,...... (/)<f)<f) (J)
(/) (/)
:;;r:;;r~;;;:;;;:::;;:::;;:<>-o-o-o-o-o--
~88~888~88888~8
O:oo<i<i<ioO:oo<i<io"o
('I")<.f)(/)Oo-o-o(/)C"')(J)(J')-o-C<F>o.<h
co - (/) <f) co <J> (/)
. (/) .
</)
'"
<J>
</)
o
C C '5c
~ ,g 00
C U C 0 c::;:
o :> 0 :>"~
:;: Q) :;:: Q) UC>
0l8- 0Q)Q)8- ~Q)Q)g
_CI) cil:S1I)=~ "'Yu)U
.ot ~ C.ot ~ C >-::
-o~o- OlQ)OUO OlOlUO
""'5:;o;f< 3en""'5:- 3en~5:
"'" V~Q)OC"'" "OQ)Oc.2
"I{)::J 0 00.. O"I{)::J 00.. 0 01{)
U':~~COlEU':~cQ)E~-:
g~'62~~ B,g~'6~;: B,g~
t;~5: 0 l:l o.:;:t;~5: l:l o.;;;;ti~
~80~ug~oE ~80u2~oE ~8
cnc:o-~ ........ cnco- ........ cnc:o
0..0.. 0..0..
en en en en
~~ ~~
13~'>N-o~g ~'>N~g ~>
.............e:;C"')o.ocooo"'e5C'1?oc:>coGf:::
~g8~~3~~g8~3~~~8
III
>
111",0.0 U"O Q)M'" 0.0 U"O Q)I{) 0
D:: ('I')(f')C"')C"')C"') 'o:::I"-.::t~'o:::I"'o:::I" 10
u:
Ol
o
o
0..
'"
~
:c
o
~
o
C
'5
5
C
Qj
a:l
C
o
en
-
o
>-
-
u
I{)
C
o
u;
":;;
Ol
~
C")
C>-
--
-0
--
8885
.o.oocw;
-0..0(1)("11I
</)</) 0
~
o
-
.".
888
.o.oci
"''''</)
</) </)
C
o
:;::
o ~
>:J_
0> '" 0
a.Q'O
olSU'"
....an.o
0> ~ ::J
30>'"
o>o.c
OQ.. 15
~ 0> 0>
u>:>
0:::::;::>
'" 0.-",
'" 0 U
Q"O 0
U<(55
0..0..
en en
<(<(
<(<(
co 0-
aCOI!)
-co -
3:3:3:
.QU"O
I!) I!) I!)
S?888882228~
~cicicricrici,..;Lri,..;C'i..;
~(/)lt)coco<J)o-""foC")U)
~ lQr-:r-: ~~~O:C'I..
o f"'-,.-- C"') <o;;,1'MC"\I
"l;f -(/')(/) (I) (I)-co
<J) (J') (I)'CI)o
~~~~~~-o<><>~
~88888ggg8
""':ciLri.o.ociC'i'<i""':'<i
"q'<J>"-<><><r>CON-N
N O-(J')</) L{)(1)"'C"')
N (J) (I) (/)(f)
</)
>-
c
o
C
o
c"8 '5 cj,
00>:> .c_
:;:: I 0> U 0
0.- a -'0
o>oQ oliO> o~.c...
:o~c c C(J)~.b
000 mo> ~~""'::J
::2::5:U 3en E~ Q.E'"
0-~5~~~8~~8
U .O>CO>=OO>~O
OINO:: 0 > COlt> O>t
- .....0:::;:: 0>030>
u::2:-l!lQ.;;>3:o>
;g ~8 Q Q-80E 5~~ 5
uenco"-U<( U-o::U
s:
...
>
Zo 9; 9;
<(<( co
i:jx ~g: N cry~
...N3:80cocol!)....l!)-
"'O--CO-COG~-~z
~l:!83:3:3:~zizc:
:>
'"
..."'O.Qu"OO>....Ocoo-
'" <><>..0-0-0 '"
u:
(!;i888888ggg!:j
cricjdcricricridN~r..:..o
-(I)(I)COo-o-<nCON-('I
L() LO-- L()U)"'CO
l.Ci (/)U)</> (J) <.1>,..:
</) .".
C")(f')('I')(f')C")C"')C"')---
~88S888ggg
~cici.o.o.ociC'i'<i""':
C"')(/)<J)C>-<> <><J>a::>N-
co -(/)<J') Lt)<I>r--..
~ (/) <J) (/)
</)
C
.Q
C 0
o :>
=a 0> '6
0>0 a '0
~o> o~...
_(f) "UV,l CQ)I
:O~ ..... c cs::.o
OUo- 0>0> o>-::J
""3:- C 3en E- 0.",
..::; "O:lo>ocoCE
....I!):l 0 00.. 0 u<(<(
U':<(::2:co>;;:oo>~
~:I:!:I=2~~ 5>-a5 15 ~
Zu::2:~o",Q.:;:>3:o
~ ~80 ~ue"O<(0-oEu5~~
:;:enco-o:: -0::
E
'"
Z 0..0..
Q ~~
"'x <(<(
<N:>N"'COo- N cry
0",:> C'?c>-o coco LO ",U')
-()O"q'....,.-COO~-~
~a83:3:3:3:3:ziz
::!:
::!:oO.QU"OO>CS_ON
0_00000_---
o ----- -
5'!8888
~ciNNd
0-(/)(")("')<1)
~
'"
</)
</) </)
NNNNN
~8888
""':ci.o.oo
0-<.1>-0-0(1)
. </) </)
cry
</)
o
'0 C C
~.Q ~O>
"'~ >....
~ ~ ~ ~
00 olSg
>-:1= ..... w
00 0).....
'" 0 3: 3 0>
u.a- <DO..c::
C< o I!) 00..0
<::2:-::co>o>
:l;~:I:!~~3:
Z u::2: '" 0.-",
00>8CJoU
-0. ~"OO
;:encoU<(<D
E
'"
Z 0..0..
Q ~~
<~3:~g:
!:1u....S?~~
~::2:83:3:3:
::!:
::!:cryO.QU"O
o-~~~~
U
N
0>
Ol
o
0..
'"
~
:0
o
::2:
o
C
'0
5
C
m
<D
C
o
en
-
o
>-
-
u
I!)
C
o
u;
:>
0>
0::
cry
0-
.....
'"
--
~88888~88~888~~~8g
~OONNO~OOO~'~'O~ro~ro~
~~~~~~~00~ ~~~~~~
~ ~~~ ~ ~~~ ~~~~~
"'t.-- co ..- .......... co
~ ~ .- 0 ~ W ~
'" ..".
8~82:
NN"'-:
-0..0"""0
r--:cql.Q~
u)"'tC0";
(I).<I>NCW')
"'..".
L()0.8"f
- - ..,
C")Na:i~
.....-or---II)
C'{cqcqO
C"') ""'::t "'1 ..
(I).<I>(/)~
..".
NNNNNN~~9~~~9NNNN
~C"')~
~C"')-o
~88888~88~888ggg8
"'d~~~d~dd~~~dN~"'~
"'1<1>,.....-o-o<l>C"')<I>(/)~-o-o(l)CON-N
N ~<I>(I) CO -<1><1> ~(I)r--.C"')
N <I> ~ <I> (/) (I)(/)
'" '"
L()"'8
Or-...
~O'"
'<t N-
--oeo
<n"":<I>
'"
L()"'8
Or-...
~dM
'<tN-
--oeo
<f>,....:<r>
'"
>-
C
o
~
en
(;
-
(jj
0>
(; .....0
~ Q)-
..It... ..... OJ ~
U ~ _ ,
"0 O,c
-.Q.!::.::l
0."" U CI)
0"0
CYC"O
=00.
C U 0
:::> >- CY
~ID:!::
0>- C
CO=>
U5cc-o
fi
(;
-
(jj
0>
(; .....0
~ Q)-
- - O>~
U ~ _ ,
"0 O,c
-.Q.!::.::l
0."" U CI)
0"0
CYC"O
:!::Oli
C U 0
:::> >- CY
J!2a;=
0>- C
.f;O=>
en<Il-o
C C
o 0
c"8 15 C li ~
OQ) > 0 > .!::._
~I Q) li Q) Uc
0.- 0 0 0 '0
Q)OQ ~Q)Q) ~Q) O-.!::.~
D~OC -Q)~D~ Q)-~Q) E~~~
O~O Q)OUO- 3Cfl Q)-_::l
~ UQ)~~~~~5Q)oc8C~8C1)
o.~OO>~.Qr-...~~OO>~.QO~~O
U .Q)CQ)""U .~~CQ)""OQ)-O
ONCYO>CON~Q)O>Ct>Q)t
_I_CY~0>_IO_CY~0>Q)03Q)
O~-~o.""O~>OE~o.~>~O>
Q)8COOEQ)8> OOEC ~C
0. 0_"0 0. OQ)-"O O~~O
eneo~U~Oeneo~CYU~OU~CYU
CI) -
~~ ~~ DO c::
en en en en ... Gl
~ -
~~ ~~ ~ E-"'- c:: ~'" ~
~~ ~ ~~ 1: 02: g;s Gl -0.'"
~~8eoo. ~N-oeoo. N "'N < E a_eo
OCDCO""" C":)OoOaJCOlOr--.l.()- ::c C--'<t ~_'<t
o.-eo-eoOUO'<t'<t~eoo"'-"'Z U Q,ZZZ t ZZ~
28~~~~o8~~~~~ZIZ~ Q)I-....JI- 8- Z~Z
j1;; QZ~Z
Gl Gl
O.DO"oQ)L()O.DO"oQ);n-oOr-...eo ... Q
'<t ~ CJo.O- N"''<t
::!::!::!::!::!-~~~~~--~-- :g-NN CD NNN
-
... .... ii:
'"
Q)
0>
o
~
on
.!!!
Ii
o
~
o
C
~
o
C
(jj
<Il
C
o
en
-
o
>-
-
U
L()
C
o
"in
>
Q)
CY
'"
>t.
-0
~
-
<')It)8CO
"0 ....
d~M"
N"","-,....
..qU;~~
- N
</) ..".
<')It)8
"0
a...rcY:i
N'<T-
-o-CO
~<J)(J)
</)
x
>-
C/)
o
-
iii
o
(; .... 0
......co>o
OlU 0....
C"OO.D.
~Q..c::s
'6oU'"
CC::"O
O:t: Q.
U C 0
>- ::> C::
<D~:t:
- 0 C
DC::>
ccU5..o
I:
o
0;;
">
is
..
1:<')
.Qo-D~
'O_-'<t
.Q~~~
S[l.ZZ
E
Elt)o.o
8N~~
N888'<Tlt)-
""f ~O-c:o
O:ci<i<i....:<ri~
C"')<J>-o-oo.o-oO
~ <J'>(J')~<J)~_
- N
</) ..".
~888~~
O:ci<i<i"":<ri
('f')<I>-o-oo-o-
co <f> <J) C"') <J'>
. </)
</)
'"
z
o
~
....
'"
Il..
g
'"
...
Q
'6
;2
.D.
<D c: ::J
0l~2g'"
Gl":" O[l.OC
uU COlCi;Ol
=Q~~~oc
o-~",o.~<:
l!!~80.g~0>
~a-cou<:u~
I:
c
E
E [l.[l.
00 ~~
x <:<: '<T
.l:NO>COQolt)'<T
u"e5oco;8-o
~~8~~;:8
Gl
u-o 0.0 U"O"
=",-0-0-0-0",
o NNNN
Il..
;g888~5?~
a::iciNC\i~'-:O:
"""'<J)('t)C"')o.o-N
-0 --"""-0-
~ (I)<f>(/)<f)~
</) ..".
NNNNNN
~888~~
O:ci<i<i"":<ri
('1")<1)-0-00-0-
co {)')<.f)C"')<f>
. </)
</)
~
Gl
lJ
8
iii C
Gi 300
-,...... O>O:+=c
J::., 0> 0.. 0 c:
Ou C(J)Ci;Ol
"':OINQ~-c
c- ~_o~
CD-~ en .0..':::--
-~ U"JoC:o
.0 0. 8 2 "0 0 0
liC/)coU<:U>-
'I::
C
::J
C" [l.[l.
-g ~~
Glx <:<: '<T
:l:N;:COQolt)~
cGo~~:8u..
.208;:;:;:8
'0
U)co 0.0 0"'00-
!N~~~~N
u:
~888
"":ci"<i"<i
l.l) <I> <> -0
<') N N
r--.~ <f> (/)
</)
-0 Olt) 00.
r-.. co -- co_
0: coi.QC'\i a:)
rocc-No.
1LlC"')(I)(I)ClO
,.....U> 0:
</) ..".
<o:;t<o::t""f"'t<o::t<o::t--
~888~~~g
O:ci<i<i"":<ri<iN
C"')<I>..o-oo-Oo-N
co <.r> <f> C"') (I) <f> <f>
. </)
</)
'6 '6
:2 0:2
~ 0) ~ I
'!:l ~ Ol~ ::,1i: .c
_Gl C _ ::J
"''E 3 o O[l. Ol'"
~":" ~~'5E8'"B
..U C 0lCi; Ol",,~
I:ONO> c.::::u..
_IC:::;::O ZI
.2-""",0.-<: ::>
-U"::::U)o--Q)
!2~82"O58'0.:&;
8.C/)cou<:u>-~~
o
>-
lJ [l.[l.
i Cf)Cf)
!2'x ::1::1 ;;::ri:?3
GlN;:COQolt)'<Tg)g)
E"o~~:Q~zz
"'U"O>O>~OOO
=000>0>0>............
c
:I:
,.,.~ 0.0 U"O_ 0.0
0- ~.~ g ~ ~ g C"') ~ ~
'<T
Ol
o
o
[l.
'"
.9?
:0
o
~
o
C
'2
o
C
iii
lD
C
o
(J)
-
o
>-
-
u
It)
C
o
"in
;;:
Ol
C::
<')
Q:.
-0
-.
-
-
8~~88~
N8.O:ciN..;
0. (f')COLOoO
,,!--:.o:'<?'f"-.:.,....
l.{)~r--.......N...:
<f)<f)r-<f)<J)C")
'" ..,.
~"~. ~."Cl ClCl
~LOL088
...tNNO...r
""OO-~
N.- - NC"'J
(f) <J> (/) <f) <f>
...
'"
:::i
...
Z
w
::iE
...
5
OJ
w
Q
C
~
Q}
15
.sZ 0
0. U
~ :t;:Q)
~~()cg'6
::!EQ}::!E:)'t::o
Q)t:~Q)Q)t-
()o~EC'
cCDQ) _$J
o >-~Q5"t)c71
='13Q}::Cc
Q}oo.QlO
C: o.cnTI..c
en:J 0 Q} ()>-.!:!
U- -
~ 0~3
<{.cEEen
~~~~5:
w
-'
III
~
'"
o
...
-
c
CI) "'-0
E"':;:;~"'E
t:g",-o~o
c"''''ZZ()
Q,ZZ::!EO-
gzzzCDc9l
CI)
(,)NCl?oq-LO-o
15(1")('1")('1")(1')('1')
...
0"''''
C')-~
lcia:iC'i
""''''
q~1I)
'" -0 .
<1><1>2;:
g~
"''''
NN
DO
'" '"
~(J"6
Q)--
:;::::!E,2
0";::-.
CDQ}$J
>- ->< ='
",,0'"
() Q}
o 0.
0. en
o Q}
Uo
.c E
.Q>Q)
::C~
'"
Cf'-CX)
Cl)N-
E"'-O
"'z
tZ::!E
8.z Z
CI)
C"ClCl
CI)",,,,
M
il:
NN..,
000
triLrici
00_
NN..,
'" "'..,.
f!.j"N
"''''
NN
DO
- -
'" '"
~()'6
Q)--
:;::::!E,2
0":::-.
CDQ)$J
>- ->< ='
",,0'"
() Q}
o 0.
0. en
o Q}
Uo
.c E
C.Q>Q)
O::C~
iii
'>
is
.. '"
C,,'"
ON_
-"'-0
C"'Z
.l:!~::!E
SZZ
E
Eo-o
0"''''
u
000880
co-- 0
crjL[jL{jdcriC\ii
D-NNNCOII)
f',.OO~-Oo.
<f)"":'-:U><.r>~
"'''' ..,.
('I')S~NN
~LOL088
oq:NNO~
-ooo--.:::r
N'-- -N ('I')
</><h</>(/)(/)
Q)
15
~ 8
~ +- QJ
~~()cg'6
::!EQ}~:)'t::-
Q)::::---Q52~
().gIDE.f.a
C>--><Q5"t)='
~""g::cc'"
Q5go.Q)O
..2:o.en(3.c
CI):JOQ}>-()
_enu+-():!;:::
c~ 0-3
Q,<{.c EEen
"':s:.Q>Q)0~
5en::c~::!Ea.
iii
'>
is
~ LO-C
O"':;:;~"'E
'5~~-o~o
()ZZ~OZ.!:!
-......"" ~
SZZZCDCl)
E
E-N"'''''''
0"'''''''''''''
U
888888
~ciciNcOci
(:So-NtOOo
~U1QC'!.~~
C")--- ,...,
<I)<f)</)(/) 41)0
NNNNN
88888
~.L6ci"":-.:i
o.-~o
f',.I.O-oN
'-:<f>(/><J)<J')
'"
Ii;
:::i
...
Z
w
::iE
...
5
OJ
w
>
U
z
w
~
C
w
:::i
-'
<
ID_
OlC
0;2
.c,
Q) U$J
15 ='
o E :g '"
t: 00.
o () 0
a.. _00:::
u;~CDt:o.
~-<::-EQ}0
CD "" 0 1::l<
CI){J8EoID
()en",enUO
=
o
"0
.l::
C "''''
8x ~~
_Cllx -"
~~~.~.~
c
~-oo.o"",
:5:"'~~"''''
U
'"
'"
cO
"
-0
CO;
'"
N
N
'"
0:
'"
<Xl.
'"
~
15
o
::!E
"
U
~
-
()
CD
0.
en
CI)
o
5
.~F:'i
CI)"
EU
0.0
~
~~
u
'"
Q}
Ol
o
a.
'"
Q}
15
o
::!E
o
c
'0
o
c
ID
CD
c
o
en
'0
>-
-
(J
'"
c
o
u;
>
CD
~
'"
0-
--
-0
--
88t!;888
ddNNNO
<J> <f> 0- ('I') C"') (J)
0') --
</"J> </)
NNNNNN
88S888
00-0-0-00
<I) <J> 0- <> <> U)
- </) </)
</)
c
o
:;::
c 0
o "5
=a Q)
o 0
.. ...., CD
_ '"V~
150- IDOl
3::'5~CD~~
ID:J OOlCL 0
':<{~CCDE
N_<DO>C
:r:O-~+=.Q
~:>O..o._
:> E .. 0 ~
~;:?~8~6
CLCL
CJ> CJ>
<{<{
<{<{
3::~~:g~CO
O'l;;too::r-coo
83::3::3::3:3::
O.Q U"O CD.....
o-o-o-o-O-S?:
oo::roo::roo::roo::r<o:;f"'t
888888~
~.oooooO:
~CO(/)(/)<f><>,...
. cq ~ "rO
C"')N "', ..
(/')<1) 2
.".
C"') (f') ('I') ('f") C"') C"')
888888
8-.00000
0-<1><1'>(1)('1
N..... -
~<J> (I)
</)
co_
OlD
0;2
CD .c ,
]5 U.c
o :Q~
t ", 0.
o ~ 0
a. _(])O~
8~~"8Ug.
N~t~ID:S<
CJ>8002:..
~cobj~~8
co
~I ~o--o
O-~"",-o-Z
0('1)(',1(1')1-
INIIIZ
oO.QU"O_
1D1?l1?l1?l1?l1D
888888
g.oo--';3O
1Dg:;;:;:;!iN~
_'(f)U)(/)(.f)~
</) .".
88888
g~;:!--';3
1D.....ID:;!iN
,..:(/)(/)(/)(/)
</)
co_
OlD
6;2
.c,
Q) u.c
]5 ='
o E:QU)
to 00.
o U 0
0... _o~
Ci1~~to.
Q)-""t~O
uQ)""oc~
=-88EoCD
OCJ>COCJ>UO
'E
Q)
E
Q)
0)
Ox
c(]!
c"":J:,,
:Ea~O')
...INI
..
i52 O.Q
~N N N 0') ~
=1.01.01.0101.{)
(,)
0') co
~ID
- N
- .....
ZZ
I- I-
ZZ
00...00<<>
"1000"1
.nNOO"':
-.:t",coo."'l:t
"Il:fIt)ClD-C
0:.000:.0
N.n-<oc:I'''''=I'
"""oCI)ooCl)ooU>CO
.". ..".
'6
'0
~ '6
i ~ ;g
E....-
a....c='O
_Q)O)DC
='-Gi'liiD
cro_c,'rt
1.1.I Cf).... _ \,;I
-
Q
u
:::: 0
- :::; 2
- ~ ~
>.:::: :'>
'"
.: t> Q.)
:r. ;:: :J
'K :
u "
_ t:.-
ti c3
:.:' - -:::
::: - ::l
"
U - ;::
<
.;2 g
~ E ~
,:' :..l ~
.: u Vl
-~~
C N i
11"". - ~
~::;;<:::
-
:r._~
:.;:X: :.;
.~ 1;:=
- "
1:: :>
~ -
u
u ::: -
. _ t':l
.~ U 0
]?
fr~
~
z
~ ....-;:l
.!!
:::~
= ~
~ ;;.E
= 0
.D
;;
"
:=;
"
'-'
"
'5
g
.~
"
-ji
~
.2
E
:5
.E
"
;:; -
.",~
=-~
c ";
u ::r
~ ~
::l ~
In .=
5 0
'';: :.;
"
C;;~
Q.;;:
::> "
~t)
~ ~
~ ;:!
~ :;
< g
~
"
t.:..
>
.~ .
_ :r.
:r. 0
'x .-
u
"
~ ~
'-'
(': ~
~ -g
ii-
~ ~
,,-
-:; ~
~ E
u
= ~
;l
~
~.!:::
-= ::;:
:=>
- -
eoc
" ;;:
- "
~=
="5
::> c:
'" ::>
;:: "=
Z.:s
-"';
~ .~
-0
OJ
Ol
o
CL
..
.!!!
]5
o
~
o
c
'E
is
to
OJ
co
c
o
en
'0
>-
-
o
ID
C
o
-in
"5
CD
CO<
,.,
0-
--
-0
-
--
<J]<oil
f-Q
~~
:;"
<oil""
U:::l
Z<oil
:$....
z~
<oilZ
=0
UU
f-
-<
""
;!l
Q
o
Z
-
Q
cz: g
< .-
~ ~
<oil E
IDS
z.9
..: 00
{/J .S!
'- .c
0""
;>-
f-
a
f-~
OO.,f
0<0
Uo
0'<1"
w
O~
z'"
w
f-
X
w
1n000
....~~~
NMlJ')LO
_(7)C"\IN
NM-_
00--
0(").(/)00-
~ ...
...
00000000000
OlnOOOOOO'<l"OO
CDcnco~cici~Lt)cno"'"
COCO_I.t)LnLnNCX)U1I.t)_
LON COr---NNN.....cocor---
f'oC'ol0CC00__ f'.N
o(I)N <1)0 0N~'l:t0-
.co *00 -0
Oln
~'<I"
CO '<I"
O>~
co
0'"
li;lnlnOOO
In"" 000
8co'<l"r'.o1n
...."'....NN
CN.....M-
Z ~.,.:M00
~ o(f)o.- 0-
...
OltlOO
0....00
co.,fco....
CO "'0""
CO_MM
0..-0(")
~ ...
...
....
II>
CD
..
l1.
00
00
0.0
ltlN
'<I" CO
0'"
'<1"000000000<00000
....00000000<00>00 ~ ~
cemocicOmcri-.:ic:icriaiui N f' LO
N-q-ONLnM\t)OCDM0cn,.... m.-
~:S~:::~~~ ;;;: ~ ~ ~
000_000 *4)
...
...
0000000
~~~0'<l"~0
LOLO_f'll>O'"
NN..-LOOLO"!:t
__MCOMN
.(/)0 0 4). ~ M ~.. -0
...... ...
OltlOO....OOO
...-oo:tOOMLOOO
.....,fo.o.,f.,foo
('\1..-1.0,....<0,....00)
0)00 C)0'1:tcoom
000 M0~0
... ...
00
O~
~'"
CON
... '"
...
OOOltl<Oltl 000
OOLO"l:t_r--O~~
<occir'cciocci.,f '" ltl
NM"l:t**oo:tNM-
N00 0"ltM*
... ... ...
>-
~-mmC7)m::NNNNN
o
Z
o
i=
0-
il:
U
00
w
o ~
:J
'"
o ..
u(.)"E~
c: ~ to ~
w~o-,
~~~~~
_~;"O-,
Ula:o~""
~~g=~
o c: CZ) U..::
>~oc.J:
~_:JEE-o
.. 0 c:
_Ua:UN
-0
:J
C1l
II:l
o
o
<0
0>
O-UO
;rl<{'<I"<{<{<{
O..-.....COOv
00<0"'....0
CO_NLtl"""
:2 1I:l~~~
II>
~
:J
en
o
U
c:
w
..
OJ
C1l
-
~
..
~
..5
II>
"0
en
c:
o
~U
C1l C.
II:l 0
~
~".
o '"
o ..
lJ..0
~
In
~
'" 0
Zltl<{
U"''''
0<00
O~....
OCO~
-0
:J
C1l
II:l
o
o
<0
0>
"-0...,
c: ~ <.>
o C1l C1l
.::0-,
0.1I:l
o ~
;:; s
"- C1l
:2 ~
". 0.
alO
c: '"
.. ~
en 0
o E
o '"
t.?a:
~".
'" OJ
en C1l
-0-,
C1l ~
'" II>
J: '"
~-o
OJ C1l
C1l II>
c.J:
E-o
o c:
UN
o
o-Uo....
<{<{<{
co 0'<1"
"'....0
NIn....
~~~
Ln- -_ NN_cccoCOcoCX)~CD~~~m-
___ __ __ N\O N
~
..
0.
o
-0
-g.E
.. 0
Q)~~u
'1i -::: Q) I:
to - OJ-.:t
uJ;B-
~olJ'O~
C1l c:-o
't: ~ a: ::s
CD to . U
-u't:E
..5 :J
..."EcnN
Q) to OJ (J)
~ u c: 0..
co llJ :e :E
~~~1I:l
>-
~
c:
C1l
~
~
C1l
>3:
c ..::
o >
0'"
l1.o1.l
'"-0
C:.c
o >
'+:i CD
'0 ~
~ ..."
o
~
"c
o
:2
>
C.
0.
:J
00
~
..
~
o
l1.
en
II>
-0
:J
U
c:
""
'"
-0
~
C1l
U
-0 E
:0 ..
u-g
E :2 E
~co~
o ~ 0
:20:2
-olJ..-o
:J II> :J
- co '- to
~al~al
Jtooo
UOoO
cuc.oc:tC
~mwC7)
<{
6
o
In
",O>N
:20>0>
l.Dul.t)O
<ONO~~
;:2;!ooo
1I:l1l:l0f-f-
MOOMtC
N<OO<O
IOMLnMN
00,......00""'0
ZZZZ".
oooo~
f-f-f-f-al
:2
w ta.Qu ta.cu~
C_NNNNM~v~~~~~~oom
~
o
~
0.
C1l
-0
<( ~..;,/.
~ c. OJ
c: c. C1l
:J :J a:
000 II:l
:2~w
"'u
". ~
OJ 0 .::
~Q..u
r: c:a..s
"'wo
UO>
II>
~
III :J
~ en
Q) ::l 0
C ~ 13
o 1:5 c
f- c: W
enw
..
~'<I"
"0
a; <0
o~
Cl oll:l
C Q) UJ CO co
02"3<('-"-
oni-o-,E.2
'=~"Sa;a;
'- III c: c:
o Q) to ca
~uC:a..c..
~ C1l 0
OJ 1: >~ ~
OC. Q) co .- 00"-
~a;(f'J
>-a::u~
nJ~t-c.~
OC'l:lt-c.o
_1Ila..:J..J
:;t:;t
00
<0<0
~
<( S S
'<I"~~
000
<0<0<0
ai-=.
a;'ii
c: c:
C1l C1l
c..0-
~
c: c: '"
.g .2 ~ "5
.U).~ ~ Z
C:C:a1~
to ~ CD......
'=t-c:~
.... '- '5. X
~~EN
C.cl2C?
:J-IUCC
'"
0>
-
o
~
-
~
~
~
'"
Of-
"'z
~:2
.8
a;
~ c:
o C1l
~O-
~N
Qi - en
c: - .!' ~
co c....
0.. U c. ~
c U :J C.
g ~ en (/)
'Ci) ... Qi a)
c ~ ~ :0
f! c. 0 CO
f-OOO-u
'"
c:
o
"iij
";;
..
a:
o
Z
i5
a:
<{
Z
a:
w
II:l
Z
<{
00
lJ..
o
>
f-
G
N
00..... ......
<{<{~:20 0
C'"lcolnO~ ZNO'<l"
gf'~;;;~~~",gg~
No(5<<;NNOO)C') N M ~
~OZZCOCONNCI) l1. Z Z
a1Qa5ffi~~~~;tg~~
O_NM~~~~OO~O_NM~~~~OO
....._ __NNNNNNN N N
CO
00
inN
'<I"U
0-
1I:l<{
oo~
'"'i:I
i5~
:;;"
ij~
;Z;~
<..l
=0
;Z;oo
~;Z;
=0
UU
'"'
<
=-
(!l
i:I
~O~OOOOOO~OONOOO~~OOOOOO
NOOOOO~_~~~O~OOOOO~OOOOOO
~o~d~ooO~O~~~Md~~-~d~~o~d
_~OO0m~0N~M_~M0NN~00~~~~-
LO __ r"'-1"'"I:tC00N 1"1"(") __(.T)"d"f'
.(I) 00 __00 0 00~M N~0
0.(1) N *M *0
<I> <I>
~
~
<I>
- -
<I> <I>
~~OCll
~NOCll
~",dc:i
C")cnNIt)
~~~Gl
~. M <<i .;
MM...,....
~<I> ot
<I> ...
00
CD
CII
ca
a..
NONoooo~i~oONOOO~NOOOOOO
~oOoooom~_ooo~OOO~~OOOOOO
md~d~<<io~~<<iN~mo~~~md<<i~~~d
M0m0~m*(.T) _N_M0WWcnC")0COCOWcn-
CO 00 0-00000 00(")00 00_oc:t'"
0_ 000
<I>
-
<I>
-
co en 0-
...CDc::J!
o )( .- 0
I- CO g; I-
~~t5
E g
.9- -I
::l
0-
W
0
;Z;
- M
i:I
== c m
-
< oS! 0
~ 1:; -
-
~ E -
=,s -
z.s M
< .. c:
00 " 0
... 0;:; 'W
0 0;: .;;
=- CD
;.. a:
'"'
-
U
Ul
c:
0 ...
ca .'" c:
c: CO Ul ::l )(
CD Cl c: ... CD 0 CD
Ul CO ::l CD (J) .;;: :::E -
c: c: OJ a: ... CD - 0 0
- CD c: ::l c: - - CD Ul - E
... 0 CD (J) CD )( a: CD <( ~ CD c: ;: Ul 0 CD
c: ;: ;: 0 CD ...
'6 ... CD (ij 'c :::E
::l CD c: c: CD .!!! CD .'" CD 0 <>
0 ::l OJ 0 0 <( :;:: (ij :::E ~ Cl 0 CO ~ Cl a.. <> 0
~ a.. - :c a..
:::E <( c: .'" CD U c: ... U c: <( :::E .;
U N CO CD 'C '0 0. :::E LL 0 N CO CD (J) N CO CD ;2
J: ... J: J: .~
CO CD ... a: > !iF CO ::l Z :::E ca J: a: > 0 CO a: < .J:;
- :::E ... .. .'" >- (J) ::::l - :::E .'" - :::E ... <> ...
... 0 3: Ul ... .. - ... Ul c:
<> Ul 0. .", . CD > <> Ul 0. ... <> Ul 0. .", E ::l
CDO E .. aJ 0. :5 ... CD 0 .. c: CD 0 ..
0 E ~ 'c 0 0 E 0
0.0 CD 0 - '0 '0 - > 0. 0 - '0 0 0. 0 - '0 ~
(J)OO a: U <( 0 ~ - I- :::E ::::l (J) 00 u <( u (J) 00 u <( 0 - :::E
0
~ Z
a.. a.. a.. a.. a.. a.. aJ 0
(J) (J) (J) (J) (J) (J) M
<( <( N M 00 N <( <( <( <( M M a:
<( <( ~ ~ III ~ 0 <( <( x <( <( 00 :::E <(
x ~ ~ ~ m 0 U ~ Z
N 3: rJ:J N 00 m ~ 00 00 00 ~ N 3: 00 m ~ N 3: 00 m ~ U a:
~ 0 m M 0 00 00 LL Z Z Z LL ~ 0 0 00 ~ oil 0 0 00 0 z c W
u ~ ~ ~ - co 0 C 0 0 0 <( u ~ - 00 ~ u ~ 00 m 0 0 aJ
C 0 3: 3: 3: 3: 3: l- I- l- I- J: C 0 3: 3: 3: c 0 3: 3: 3: aJ 0 Z
<(
(J)
LL
0
.. .c <> '0 CD - .. .c <> '0 .. .c <> '0 >-
m m m ." ." ." ~ 0 N M ~ ~ ~ III ~ III ~ rJ:J rJ:J ~ ~ ~ 00 !::
N N N N N N N M M M M M M M M M M M M M M M M M U
<I>
"
(,,)M(,,)MMMM~8~~M-
-
_cocccoooco
- - - -
_ _ _ _ c:n _
EXHIBIT F
OYfIONAL SPARE PARTS
(Deliverable After Contract Signing)
EXHmIT G
MOTOROLA "FNE INSTALLATIONS" QUALLlTY STANDARDS
1. JOB SIT-: SPECIFICATIONS
1. ACCESS ROAD CONSTRUCTION AND
SITE IDENTIFICATION
Sile access roads should be easy 10 fme! and should be
passable in all weaIher condilions using a tw()owheel-drive
car. This allows building c:onll3ClOrS and mainlenance per'
sonnellO have uouble.frec access 10 Ihe sites. This is particu-
larly imponanl when sileS are localed in remOle areas. Some
CUSlOmer5 will IIOl allow lhe posling of signs for security
reasons. If this is lhe case,lhen an adaquale Slrip Map should
be made available.
1.1 GENERAL
In order 10 easily fmd an inslal1alion, a sign must be posted al
the entrance 10 the sile access road. This sign needs 10 stale
the name of the access road or the address of the aClUal
installation. Leucring for !he sign must be large enough 10 be
read while driving at the main road's speed limiL The sign,
when compIele, should be posled before the building con-
sauclion begins 10 allow conlrllClOrS lhe opportunity 10 quickly
locale sile installations.
Engineering practices indicate thai the road should be able 10
withstand two times lhe average vehicle's gross vehicle weight
(GVW). Since normal service vehicles are in the three IOn
class, a road should be buill, alIeast. 10 Ihe six IOn GVW
specification.
Where safety prevails. lhe road should be wide enough for
IwO seven-fool-wide vehicles, plus two feet of clearance, for
a minimum ofsixleen feeuDtal width. A six (6) foot shoulder
or a guard rail is required for safety reasons where roadside
grade exceeds fifleen (15) pen;enL If there are curves in the
road, a minimum of a twenty foot lUrIIing rlIdius is required.
Road grade should be limited 10 lifleen (15) percenl maxi-
mum and the average grade should IIOl exceed len (10)
percenL For year-round accessibility, the grade should be
limiled 10 a maximum of leD (10) pen;enL
The above SWldards will be followed unless swc. county, or
local requiremenlS exceed these limitations.
11 shall be Ihe road building subconlrllClor's responsibility
for lhe following:
(I) ProlCCt!he properly of others.
(2) Exen:ise due caution and follow approved safety
praclices.
(3) Clean up all debris which resullS from his work.
Any burning sha1l be done only where permiucd.
and local fue ordinances shall be followed.
(4) Furnish all labor, materials, equipmenl, and super-
vision 10 properly accomplish all tasks as oulIined.
(5) Propezly identify !he localions of roads,lIII1I-1ItlIIIId.
and parking areas as shown on the lot survey.
(6) Obtain any required permilS for road consauction,
inlCrface with existing roads or _IS, and follow
local ordinances govaning such intafaces.
(7) Furnish all walel' 10 be used on the work sileo The
conll3ClDI' sha1l furnish Ihe necessary remporary
piping or hose from Ihe dislribution point 10 the
poinl on Ihe sire where WlUCl' is needed.
1.2 GRAVEL ROADS
,
The following specific laSks shall be perfonned by the road
building subconlractor:
(I) AU surface growth and vegetalion in lhe areas of
new roadway and lUJ1\-around parking is 10 be
cleared. The exacl depth will be delennined by Ihe
location of the sile. Roadway clearing shall be wide
enough 10 instal1 a road thai is alleasl eighl feel
wide. In areas where safety is an issue (blind cor-
ners. SleeP roadside grades, and roads with long
descc:n1S), a wider clearing is required 10 allow for
two-way lrafflC flow (see Para. 1.1). Turn-around
and parking areas shall be sized as indicaled on the
101 survey.
R56 (Change I)
QUALITY STANDARDS. FNE Installations, Vol. 1
1-1
< mB SITE SPECIFIC A TIONS
(2) The road shall be graded 10 make it usable in all cleared. Roadway clearing shall be wide enough to
weather. In areas where the road base is insufli- install a roadway that is at least eight feet wide. In
cient, excavation and/or replacement will be needed areas where safety is an issue (blind comers, steep .
10 keep the specification 10 the minimum selected roadside grades, and long descents), a wider clear-
standard (Le., 6 IOn GVW) for the entire length of ing is required 10 allow for two way lI'affic flow (see
the road. Para. 1.1). Turn-around and parking areas shall be
sized as indicated on the lot survey.
(3) Final grading will allow the fmished road 10 have a
two inch high crown in the cenrer. (2) The road shall be graded 10 make it usable in all
weather. In areas where the road base is insufli-
(4) The new road is 10 be f1ared at the intersection of cient, excavation and/or replacement will be needed
the existing road with a 15 foot minimum radius. to keep the specification to the minimum selected
standard (Le., 6 IOn GVW) for the entire length of
(5) One inch gravel will be accuralely spread 10 a loose the road.
depth of eight inches (minimum) on prepared road-
way. (3) Final grading will allow the fmished road 10 have a
two inch high crown in the cenler.
(6) Four-foot-wide, V -shaped drainage ditches will be
on each side of the road bed, where necessary, for (4) The new road is 10 be f1ared at the inlersection of
the conll'Ol of surface waler run-off. the existing road with a 15 foot minimum radius.
(7) In areas where grade cannot be mainrained because (5) In areas where grade cannot be maintained because
of steep slopes, fill should be used 10 correct the of steep slopes, fiU should be used 10 correct the
problem. Furnish and install culverts where neces- problem. Furnish and install culverts where neces.
sary to conuel drainage. sary to control drainage.
(8) The completed road shall be of a quality and con. (6) The completed road shall be of a quality and con.
figuration 10 enable the passage of a 20 foot long figuration 10 enable the passage of a 20 foot long .
flat bed !ruck and/or a loaded five-yard-capacity flat bed truck and/or a loaded five.yard-capacity
concrete truck, both lI'avcling under their own power. concrete lI'Uck both lI'aveling IDlller their own power.
(9) Overhead road clearance shall be maintained 10 a (7) Overhead road clearance shall be maintained 10 a
height of at least 15 feeL height of at least 15 feeL
1.3 SOIL-SURFACED ROADS 2. MUD. FREE BUILDING ACCESS ,
Soil-surfaced roads have the distinct advantage of being less
costly to build than gravel-type roads. These cost savings,
however. have to be considered very closely, because road
conditions may deteriorate due 10 climatic variations and/or
vehicular lI'aflic. This could limit the delivery of equipment
and materials during the installation phase. Maintenance
personnel may be prevented from immediale access 10 the
sitc. jeopardizing equipment serviceability, if the road is not
properly maintained.
The following specific tasks shall be performed by the road
building sub-contractor.
( I) All surface growth and vegetation in the areas of
new roadway and turn-around parking is 10 be
In order 10 access the building without lI'acking in excess
mud from the surrounding area, gravel must be in place prior
10 the completion of Ibe building interior and equipment
delivery. Failure 10 do Ibis will increase the amount of loose
din that is lI'aCked inlO lhe building. This din presents sev.
eral problems. The dirt, when dry, can become airborne from
Ibe movement of personnel and/or air handling equipmenL
The airborne particles settle on everything and can contami.
nale Ibe surface of elecnical contacts on sockets and assem.
blies. This small contamination can cause intermittent
operation and reduce equipment life. When wet, Ibe dirt
usually becomes slippery. This presents a safety hazard,
especially when the technicians are moving top-heavy equip-
ment racks, or climbing on and off ladders during Ibe instal-
lation phase. Other considerations are that it is not profes-
sional and clean up fees add 10 the overall cost of the system
installation.
.
1-2
MOTOROLA NA TIONAL SERVICE
(Change 1) Iiii'll
1. JOB SITE SPECIFIC A TIONf'
)
The building and lOwer base area should be graded 10 pre-
vent water from puddling. The fmal grade shall slope away
in all directions from the lOwer base and building. This area
(10 3 feet outside the fence) shall be lrealed 10 prevent the
reoccurrence of vegetative growth and sha1l be covered with
four-inch-deep compacted SlOne or gravel This trealIIIent
will be determined by loca1 codes. The remaining cleared
area sha1l be resund 10 the original conlOlIIS and shall be
planted with grass 10 avoid erosion.
3. SITE AREA NEATNESS
As work proceeds. excess din and trash sha1l be removed
(Photograph 1-1). This will help the program manager pin-
point problem areas and allow him 10 inspec;t for compliance
with quoted speciflCalions.
There are many other benefits 10 having a site neat and
orderly. The first one is that subcontractors will subcon-
sciously work more carefully, tte8tthe equipmentbener, and
clean up after themselves. The second advantage is that the
customers are put al ease. They feel that they are getting their
money's worth, because they judge our workmanship based
on what they see. If the site looks great. their fIrSt thought is
that the system is being inslalled by professionals. Quality
must be everyone's main concern, so an orderly installation
is a requiremenL
4. EQUIPMENT AREA SECURITY
Since our customers have a large invesunent in their sys-
tems, it is aitica110 proleCtlhis inve5UneRt by ensuring that
reasonable security is planned and implemented. The neces-
sary level of security will vary by customer, location. and
value of the equipment involved. Personnel safety must also
be considered when determining security needs.
4.1 CHAIN LINK FENCE INSTALLATION
This section covers materia1 and erection of chain-link-type
fences that provide securily for the facilities.
The erection of the chain link fence consists of constructing
concrete footings for steel posts, inslalling braces and rails,
suinging fence fabric and barbed wire, hanging galeS, and
grounding. Good workmanship is required 10 assure that the
fence will be straight and will be in alignmenL 11 sha1l be
erected as shown on drawings pertaining 10 the job site.
Materials used shall be as called for in the plans.
Photograph 1-1: The area surrounding the building
is trash-free.
The tasks involved are as fonows:
(1) Location offence
The fence sha1l be 10Caled as shown on site draw-
ings and sha1l foUow ground lines unless otherwise
specified.
(2) Concrete footings
Footings for line and brace poslS sha1l be nine (9)
inches minimum in diameter by 36 inches deep
with a one (1) inch high crown on lOp 10 drain
moisture. AU other post footings sha1l be a mini-
mum of 12 inches in diameter by 42 inches deep
with a one (1) inch high crown on lOp.
Concrete used sha1l attain a minimum compressive
strength of 3000 pounds per square inch in 28 days.
AU c:oncrete sha11 be teady-mixed or in-ll'llllSit-mixed
using crushed SlOne for coarse aggregale~. If con-
RS6 (Change 1)
QUALITY STANDARDS. FNE Installations, Vol. 1
1-3
. JOB SITE SPECIFICATIONS
crete is "field-mixed", it shall be mixed in the pro-
ponion of one sack of cement, two cubic feet of
sand and four cubic feet of stone. All concrele shall
be made with Ponland Cement with well graded
aggregates, and shall conrain not more than six
gallons of clean warer for each sack of cemenL It
shall be a plastic mix which can be placed without
honey-combing or permitting water to accumulale
on the surface. The concrele shall be thoroughly
com pac led by vibrating or by lamping and spading.
No concrete shall be poured when the temperature
is below 40 degrees F or when it may be subject to
freezing temperatures before final set, except when
specifically approved by Motorola and if adequate
provision has been made for protection.
(3) Posts
All posts shall be set in concrele footings with a
maximum spacing of 10 feet cenrer to center. They
shall be accurately located for alignment and grade.
Line and brace posts shall be im bedded to a depth
of 36 inches with all other posts to a depth of 42
inches.
(4) Fabric
Fence fabric shall be evenly and smoothly stretched
so !hat there are no slack edges or warped sections.
It should then be securely faslened to all posts, top
rails, braces, lension wires and bars. and rods with
ties as specified in Paragraph 4.2. Unless otherwise
specified, the posts and fabric shall be installed so
that. when the fence is completed. there will be a
clearance of five inches between the bottom of the
fabric and grade. (This clearance is desired to per-
mit the placement of a four inch thick layer of
crushed rock under the fence.)
4.2 FENCE MATERIAL
Materials which are to be supplied and/or erected shall be
new and meet the following minimum requirements:
(I) Fabric
The base metal of the fabric shall be a good com-
mercial quality of steel wire, #9 gauge with a break-
ing strength of not less than 1,290 pounds. Fabric,
unless otherwise specified, will be a minimum 72
inches high with a two inch mesh. Fabric will be
furnished with barbing on both ends
(2) Zinc Coating
The fabric shall be zinc coated by the hot-dip proc-
ess afler fabrication. The weight of the coating shall
be not less than 1.2 ounces per square foot of actual
surface covered. All ferrous metals used as pan of
the installation shalI be hot-dip galvanized or Stain-
less steel. All screws. bolts. lock washers, and nuts
shall be made from srainless steel or hot-dipped
galvanized in accordance with ASTM-153.
..,
(3) Line and Brace Posts
. Posts shall be as follows: hot-dip galvanized "H"
column. two inches by two and one-half inches in
diarneler. All posts and top rail will be schedule 40
grade. The length of the posts wiD be derennined by
the height of the fabric. No used. re-rolled or open
seam material will be permitted in posts or rails.
(4) Other Posts
End and comer posts shall be hot-dip galvanized
pipe with an outside diameler (DO) of three inches.
Posts for single galeS up to six feet or double galeS
from twelve to twenty- six feet shall be four inch
00 hot-dip galvanized pipe. Comer posts shall be
nine feet eight inches long and all other posts eleven
feet I.mg. Gale posts shall have a ball (domed) top.
(5) Extension Anns
.
Exlension arms shall be hot-dip galvanized pressed
steel and mounted on top of line and comer posts to
form a 45 degree angle. Each arm is to carry three
barbed wires with the upper-most barbed wire ap-
proximately 12 inches above the fabric (measured
diagonally).
(6) Top Rail
Top rails shall be hot-dip, one and five-eighths inch
outside diamerer pipe or "H" section and provided
with couplings approximately every 20 feel
Couplings shall be outside sleeve type and at least
seven inches long with one coupling in every five to
have a heavy spring to take up expansion and con-
traction on the top rail. The top rail shall pass
through the base of line post tops and form a con-
tinuous brace from end to end of each stretch of
fence. Fastening to terminal posts shall be pressed
steel connections.
.
1-4
MOTOROLA NA TlONAL SERVICE
(Change 1) 1IIi91
1. JOB SITE SPECIFICATION'"
)
(7) Tension Guy Suand
Tc:nsicD guy SlrI/Id shall be cilller galvaDiud QIIe-
quancr inch common guy strand. minimum break-
ing SII'CIIgth of 1900 pounds. or 117 gauge galva-
nized sping stce11e1lSion wire wilh galvanized wm-
buckles and cable clamps.
(8) Braces
Brace material shall be \he same as \he lOp rail.
Braces shall be IocaIcd midway between \he lOp rail
and ground and extend from \he temlinal post to \he
fll'St adjacent posL Braces shall be securely faslCllell
to postS by suitable pressed steel connections and
uussed from bnIce post back to near the bottom of
\he temlinal post wilh thrce-eighlhs inch round.
galvanized rod. equipped wilh wmbuckJes.
(9) Finings
All finings used shall be hot-dip galvanized malle-
able iron or pressed steel.
(10) Barbed Wire
.
Barbed wire to be installed at fence lOp shall be
three lines of four-point pattem wire, galvanized
after weaving. The wire shall be installed leaning
out unless olherwise directed by Ihe owner or Mo-
torola. The type of barbed wire used will be deter-
mined by local codes.
(11) Fabric Bands
The fence fabric shall be fastened to \he line JlOSlS
wilh aluminum ties spaced 1112 inch interVals. and
to Ihe top rail wilh 119 gauge round aluminum ties
spaced around 24 inches apart.
(12) Tension Bars
Tension bars and bands shall be hot-dip galvanized
and installed by each temlinal poSL
(13) GateS
Gate frames shall be con5l1'11Cted of one-half inch
outside diameter-heavy duty galVanized pipe. Cor-
ner finings shall be heavy pressed steel or malleable
castings. The fabric covering on the gate shall be
Ihe same as is furnished for Ihe fence. Gate hinges
shall be heavy duty socket type of adequate strength
for supporting the gate and have large bearing sur-
faces for clamping in position. The hinges shall not
twW or IIIID UIIdc:r Ihe actioD of Ihe pre. GaIcs sbaII
be capable of being opened and closed easily by one
person without binding or dragging. Latcbes, SlOpS
and keepers shall be provided for all gates. Latches
shall have a plunger bar arranged to engage \he
center SlOp. For security IQSOIIS two forked Jau:hes.
one near \he lOp and one near \he boulxn. shall be
provided in addition to the center Jau:h which shall
be equipped to receive a potllnclt The gate shall be
equipped wilh a safety chain keeper. This chain will
be long enough to wrap around the gate and fence
post frame.
4.3 ALARMS
Wilh the electronic equipment facility being unaaended and
normally unmanned. aulOlllalic sYSlelllS shall be inc0rpo-
rated to proteCtlhe equipment and facility against vandalism.
surface _ter. intrusion. and fue.
The building alarm sySlClll shall be of all solid state design
and eilher \he continuous monitoring type or the interrogat-
ing type. The alarm units shall be capable of continuous
operation without _tive maintelWlce under the speci-
fied service conditions. Fail-safe operation and Ibon capa-
bility shall be provided.
The alarm system featureS are as follows:
(1) Building HilLa temperature
(2) l1Iegal entry to building
(3) High surface _level
(4) Interior fue condition (smoke and temperature
sensing)
(5) CUSlOIIIer specified options.
The aulOlllalic alarm system shall provide the following
functions:
(1) Local display wilh front panel indication of each
alarm stalUS
(2) Alarm memory to IISSUR a record of SlalUS change
oc:cmrence
(3) Buill-in recbarzeable ballCly back-up power
supply for uninterrUpted security and proteCtion in
event of power failure
(4) Bolh visual and audible alarms
(5) System check out capacity
(6) Manual override control.
RS6 (Change 1)
QUALITY STANDARDS. FNE Installations, Vol. 1
1-5
1 'OB SITE SPECIFICATIONS
4.4 BUILDING DESIGN
. a precaution to protect the equipment and facility against
vandalism, the building configuration shall be without win.
dows and with a minimum number of doors and wall pene-
trations. The exterior doors shall be of steel insulated con.
struction with welded joints in doors and frames. The doors
shall be constructed to maintain the building's structural
integrity.
The exterior doors shall be a minimum 00 feet in width and
7.0 feet in height with steel frames. Non-corrosive exll'll
heavy duty hinges and door securing mechanisms shall be
provided to prevent bowing, sagging, and deflection from
true position. Locks shall be maximum security dead-bolt.
type of non-corroding material.
4.5 FIRE SUPPRESSION
All installations must have a minimum of two five pound,
class ABC, ponable fire extinguishers. on the premises be.
fore equipment is installed.
If an overhead sprinkler system is used, a "dry pipe" system
is recommended. This type of system. upon detection of a
"'e, removes source power to the room and then opens a
JSter valve to filllhe room's overhead sprinklers.
If the fire detection system is the type lhat shuts off the
power LO the installation, a bauery.operated emergency light
source should be provided.
If an automatic carbon-dioxide fire protection system is used,
an alarm shall sound in advance of lhe release of the CO, to
warn personnel wilhin the installation.
If power connections are made beneath lhe floor of a raised.
noor installation, waterproof electrical receptacles and con-
ncctions should be used.
All personnel working in lhe equipment area shall be ll'llined
in such emergency procedures as:
(I) Proper method of shutting off power.
(2) Handling fire extinguishers in the correct manner.
(3) Evacuating personnel and records, and calling lhe
fire department.
For large, heavily-equipped installations only:
The frre detection system shall consist of a combination
ionization smoke detector and a rate compensated fixed tem-
perature lhermal detector. This two-loop systcm of detection
shall provide for the earliest possible agent releasc pre-alarm
and the confirmation of a true frre situation. The installation
shall be in a cross zone configuration for positive verifica-
tion of a fire condition. The detector units shall conform to
U.L. 268 standards.
.,
The fire alarm system shall give an initial warning signal for
evacuation of personnel and for the confrrmation of a fire
condition. A secondary alarm signal shall sound indicating
the automatic discharge of fire extinguisher agent The sys-
tem shall have a time delay function between lhe two warn-
ing signals which shall be adjustable to provide time for
evacuation or abon procedures.
The fire extinguishing system shall be a Halon gas system
conforming to NFP A standards 12A and 72E. The Halon gas
system shall be sized to provide a 5 to 7 percent concentra-
tion level on full discharge. At the proper concenll'lltion
levels, the Halon gas shall be effective against Class A
(cellulosic materials), Class B (nammable liquids), and Class
C (elecaical) fires.
The above method of frre protection is recommended for
three reasons:
.
(I) Halon gas extinguishes lhe fire without removing
oxygen from lhe room, allowing personnel to brealh
normally while the fire is being put out.
(2) Halon gas is clean, allowing for quick clean-up
should a fire occur.
(3) Halon gas will not damage the equipment
Prior to Halon gas discharge, the system shall activate cir-
cuitry to effect the following:
J"
(1) Stop all heating. air conditioning, and ventilation
equipment.
(2) Close all ventilation louvers and openings.
(3) Disconnect all ACIDC elecaic power.
The fire extinguishing system shall be manually activated by
strategically located pull stations.
.
1-6
MOTOROLA NA TIONAL SERVICE
(Change 1) 1/1191
I. JOB SITE SPECIFICA nOl
4.6 INTRUSION ALARM (IF REQUIRED)
The inausion aIanR system clelecllJC'S shall be inslalled inlo
the frame of the building exlaior door and the site scc;urity
fence gate. Bypass key swilclles shall be provided and l0-
cated to discOllllCl:t the a1ann signal.
4.7 WATER DETECTION (IF REQUIRED)
If app.OI"i.lte. the water deledor shall be floor mounled
adjacent to the eleclrOllic equipmenL The sensor shall be
completely sealed with mounting adjusunenl for hcighL Both
audio and visual alarm signals shall be provided for high
water level High water level is to be determined by Area
Engineering.
4.8 LIGHTING
IndUSttia1 grade lighting equipment shall be provided to
assure adequate illumination levels throughout the building.
The illumination for the building shall have a minimum of SO
foot candles. as measured at 30 inches above the floor. with
the capacity to achieve 100 fOOl candles at the worIt ana. A
timer switch shall be incorporated to assure positive shut-off
for operation beyond 12 hours.
One exterior door light shall be provided. This shaD be type
NEMA 3. weather-resistant and suitable for general ouldoor
application. An automatic pholO-conlrOl swilCh shaD be used
to tum the light on at dusk and off at dawn. The light beam
shall be direcled to prevent it from crossing the J1Ioperty line.
,
S. SOn.. RESISTIVITY TESTING
Prior to any inslallation work beginning. the I"...,o.ed loca-
tion should be tested to der.ermine the soil composition and
resistivity. Based on the results. the standard grounding pr0-
cedure defined in this manual may not be sufracien to meet
the required ten ohms. Alternative methods such as the UFER
ground or the use of chemical additives, such as Rock Salt.
Copper Sulfate. and/or Magnesium Sulfate may have to be
incorporaled. The system engineer should IIlCOI1Imend the
appropriate course of action.
QUALITY STANDARDS. FNE Installations, Vol. 1
1-7
RS6 (Change I)
1 :>8 SITE SPECIFICATIONS
This page intentionally left blank.
MOTOROLA NA TIONAL SERVICE
\.8
(Change \) 1/1191
j
,
e,
,
e
2. BUILDING ARF' SPECIFICATIONS
)
1. EXCESS GARBAGE AND CLUTTER
Motorola and its subconlr3CtOl'S are responsible for cleaning
up after themselves. Since excess garbage is a fire hazard, all
the packing material used to ship the equipment must be
removed.
The customer or project manager is normally required to
supply a aash dumpster. This dumpster shall be as close to
the site as possible; however, at some sires. such as high-rise
office buildings, this is not practical. In those cases a plan
must be worked out prior to starting the unpacking. For
example, the movers can unpack the equipment and remove
the larger marcrial in their van. The rest of the aash can then
be handled by the building personnel.
In all cases, the trash must be stored in a neat manner until
properly disposed of. If stored on the outside of the bui1ding,
care should be taken to prevent the lighter material from
flying out of the storage area and on to neighboring property.
~
Additional aash will be generated from the iI'$I"n.tiQrl scraps,
including lunch bags and drink containers. At the end of the
day. all personnel shall remove this aash and sweep the I100c
before leaving the site. If aash is removed daily, the chance
of tools and supplies being left at the site will be very
unlikely.
When performing an inspection. the inspector will100k around
the building for aash. Cardboard and wire are commonly
found around the doorway of a remote site. Inside, the
inspector will look under the equipment for unused hard-
ware. Unused supplies shall be removed by the subcontrac-
tors, and the last person on the site will remove any remain-
ing propertY belonging to Mocorola.
2. EQUIPMENT APPEARANCE AND
CLEANLINESS
Clean, professional-looking equipment installations can not
become reality until the previous environmental issues are
resolved. Once the din problems in the room are allevialed.
steps can be taken to improve the appearance of the equip-
ment (Photograph 2-1). Cabling probably has the most
noticeable reflection on workmanship. Straight runs and
proper b1mS are critical to the customer's evaluation of the
work that has been accomplished.
Power and signal cables shall be run with sharp corners.
while grounds and antenna lines require gentle comers.
Photograph 2-1: The building inlaior is cluuer.free
following equipment installation.
3. MAJOR EQUIPMENT
IDENTInCATIONANDLABEL~G
When a service technician responds to a service request in an
unfamiliar facility (e.g., when the normal technician is not
available), it is important that the technician can identify the
exact equipment experiencing the problem. This is espe-
cially lIUe in large, shared facilities that may contain many
similar cabinets containing identical equipmCIIL It is for this
reason that labeling specifications are so imponanL
For all contractor and Motorola equipment, a pennanent
labeling technique shall be used. Labels shall be placed in
plain view on a non-removable pan of the equipment using a
color that contrasts well with the background to which they
will be affIXed. Placing labels solely on equipment covers
RS6(Change I)
QUALITY STANDARDS. FNE Installations, Vol.l
2-1
2. BI"l.DlNG AREA SPECIFICATIONS
and modules is not advisable. however. These items may be
~asily removed from a rack or cabinet - covers could get
"apped if more than one is removed at a time; modules may
. replaced during the repair of a given unit Hand-scribed
masking tape or "Dymo"labels are unacceptable.
Important information, such as customer, frequency, u:lco
block number,U:lco line number, and circuit breaker number
will be displayed on all MOlOrola-supplied equipment
4. WEATHERPROOF ANTENNA PORTS
Antenna pons are normally sealed by the group running the
antenna lines. Sometimes this is not done properly, however,
and moisture. dust. insects. and/or rodents enter the building
LO cause problems. Anu:nna pons and other holes in the
building must be properly sealed in order 10 maintain the
necessary operating environment for the equipment (photo-
graph 2-2).
Photograph 2-2: Rubber gaskets are used 10 seal the
antenna pons.
5. MATCHING POWER OUTLETS TO
EQUIPMENT PLUGS
5.1 GENERAL
The electrical installation work shall be carried out in accor-
dance with the current edition of the National Electrical
Code (NEC), the relevant sections of U.B.C., and local code.
The initial incoming power service feeder, 10 be run by the
electrical utility company. shall be sized for the full capacity
r the building.
Voltage:
Phase:
Type:
120/240VAC
Single -OR-
3 wire
.,
120/208 V AC
Three Wye-Star
4 wire
The conduit, used for the service entrance, shall be firmly
fixed to the building wall for attachment 10 the AC distribu-
tion panel and sealed against moisture. The incoming power
electric meter shall be located 10 allow meter readings 10 be
taken from the outside of the building and. preferably. from
the outside of the security fence.
Penetrations shall be provided in the building wall for the
following:
(1) AC service power
(2) Telephone lines
(3) Transmission cables
(4) Grounds
(5) Emergency power generator.
The main distribution panel shall be sized for a minimum of
thiny (30) branch circuits and shall have a minimum rating
of:
(1) Voltage:
(2) Capacity:
(3) Type:
600VAC
Maximum possible load
NEMA 1.
.
Branch circuit protection shall be sized 10 prevent shons and
overloads that could damage the following:
(1) Motorola supplied hardware
(2) Bauery sysu:m
(3) Engine generator system
(4) Duplex wall receptacles
(5) Interior and exu:rior lighting
(6) Air conditioner/hearer
(7) Exhaust fan
(8) F"tre, alarm, and security systems
(9) Other electrical hardware in building.
r
5.2 INTERIOR BUll..DING WIRING
The interior building wiring shall be nm in electrical metallic
tubing (EM1). All conductors shall be properly sized for the
branch circuit load. but, in no case. smaller than #12 A WG.
600 V AC, copper.
All interior disbibution panels, junction boxes, swirches, and
outlets shall be type NEMA I, general purpose for indoor
.
2-2
MOTOROLA NA TlONAL SERVICE
(Change 1)1/1191
~. BUll.DING AREA SPECIFlCA T'()NS
")
applications. ElcclrOllic equipmenl room oullelS shall be
IWO (2) gang duplex nted 31120 VAC, 20 AMP, 3 prong,
heavy dUly type. A minimum o( one outlet shall be provided
on each wall with a maximum o( 12 (eel spacing betweCII
oullelS and loc:ated 24 inches above the floor. Additional
oullelS shall be provided adjacent 10 and conveniendy l0-
cated as (ollows:
(1) Engine gener2lOC - Single oudel
(2) Baaery system - Single oudel
(3) Elcclrical equipmenl- Duplex oudeL
The AC power wiring and duplex oudelS supplying power 10
the equipment racks must be auached fmnly 10 the mounting
surface. All mounting sc~s, boilS, lock washers, and nlllS
shall be made from slainless steel. bnss, or hol-dip galva-
nized. AU EMT runs shall be parallel or perpendicular to the
ceiling and walls. Flexible conduit shall be used in the
shortest possible lengths (36" max.) (or connectiOllIO vibrat-
ing loads. SlI'aIIded conductorS shall be used when run in
flexible conduiL AU new wiring shall be tested (or insu1a-
tion between conductorS, conduclOrs 10 ground, and circuil
continuity.
\
All MOlOl'Ola equipmenl must be either hard-wired 10 a dedi-
cated circuil breaker or plugged inlO a matching oudeL
Extension cords an: DOl be used. OullelS mUSI be installed
with a dedicated ground wire connected 10 the ground bus in
the distribution panel Do DOl rely on ther conduit (or a
ground return. The grounding lead on a plug must NEVER.
be removed and/or bypassed: This is an unsafe practice that
violates national codes.
For safely and appearance reasons, no signal or power cable
shall be run unprotected (or disWlCeS exceeding three (3)
feeL Cable proteCtion devices include the following: Pan-
duil, EMT, PVC lubing, rigid metal conduit. cable lI'ays, etc..
5.3 LIGHTING
Induslria1 grade lighting equipmenl shall be provided 10
assure adeqUate illumination levels throughout the building.
The ilIuminatiOll for the building shall have a minimum o( SO
fOOl canclles, as measured 3130 inches above the floor, with
the capacity 10 achieve 100 (001 cancIles 31 the wort area. A
timer switch shall be incorporated 10 assure positive Shul-off
(or operation beyond 12 hours.
One exterior door lighl shall be provided. This shall be type
NEMA 3, weather-resistanl and suitable (or general oullloor
application. An IUlOmatic phOUH:OnlrOl switch shall be
used 10 lUID the lighl on 31 dusk and off 31 dawn. The lighl
beam shall be directed 10 prevent it from crossing the pr0p-
erty line.
6, ELECfRICAL WIRING SAFETY
The following prccauliOllllrY measures must be 1aken during
the inslallation phase for the safety o( MOlOl'Ola personnel,
the customer's personnel. and other subcontractors..
6.1 WIRING FOR FUTURE EXPANSIONS
When the electrician is iDslnlCted 10 install wiring (or future
expansions, the unused runs shall be cIrcssed out o( the way
and the ends of all wires must be terminated willi wire nuts or
electrical tape.
6.1 SERVICEPANELCOVER
The service pane1 cover shall be in place 31 all limes when
work is DOl being performed in this area. If the electrician
neglects 10 replace the cover after work has been COIIIpleled,
Motorola personne1 shou1d carefully replace the cover or
report the problem.
7. DEDICATED POWER
There must be a means o( removing power &om a given unit
without disrupting IIIOlher rack of equipmenL A rack which
is hard wired 10 a disllibutiOll box shall be 011 ill own branch
circuit with a <!edirAIl'.d breaker. When the equipmenl is
designed 10 have separ:ate power feeds &om primary and
secondary power sources, eacb source must be supplied
through a separate breaker.
Where unilS an: plugged inlO a rcceplICle, both plug anl
receptacle must properly mate 10 avoid a safety hazard.
Removing the neUllai prong of a three.proDS plug is stricdy
prohibiled. Also prohibited is the use of exlellSion cords.
8. CIRCUIT BREAKERS
8.1 SIZING
The main purpose o( a circuit breaker is III sense current
within the brancb circuit, and 10 lIip when III unsafe condi-
tion occurs. Circuil breakers must be large enough 10 supply
the normal current needed 10 run the equipment attached 10
its branch circuit, plus an added cushiOllIO cover changes in
R56{Change I)
QUALITY STANDARDS. FNE Installations, Vol. 1
2- 3
2. BL DING AREA SPECIFICATIONS
lhe load, supply source, lurn on surge, and normal aging of
. 'system. This is why it is imponant that the breaker size
.,ch the load and wire size of the circuit. If this is not ralcen
inlO account, a potential fire hazard or maintenance problem
will exist.
8.2 LABELING
Each breaker in the panel will be labeled 10 identify its load.
This labeling will also be present at the equipment end of all
power runs to allow for easy identification of the circuit.
9. EQUIPMENT STABR.ITY
9.1 TOP BRACE INSTALLATION FOR EARTH-
QUAKE AREAS
In areas where earthquake proteCtion is required, it is impor-
tant to worle with the customer to determine \heir needs.
Since the proteCtion will be no greater than the building in
which \he equipment is installed, time must be ralcen to
determine \he correct me\hed to be used. Normally, the
equipment will fall forward or backward; \herefore, braces
running at 45 degree angles (from \he front and back of the
~ipment to a solid beam or channel in \he ceiling) are
_.:sirable.
The building shall be designed and constructed to resist
seismic forces as specified by \he UBC. The forces shall be
assumed to come from any horizontal direction and applied
horizontally to any level above the foundation.
A combination of loads acting simultaneously shall be con-
sidered as per UBC in determining \he structural integrity.
When baueries are used in an earthquake zone, seismic racks
will be installed.
9.2 ANCHOR SIZE AND TYPE
Regardless of size, all permanent equipment (racks, cabinets.
ele.) must be securely anchored. Anchor selection shall be
based on \he holding power required. This calculation in-
cludes not only the load factor (weight), but also \he way the
load is transmitted to the anchor (shear, tensile, combined).
The number and size of the anchors to be used is often
determined by Motorola or its vendors. This is based on
'any different faclOrs, such as the strength of the holding
material, and the likelihood that the equipment will be sub-
jected to vibration and/or shock loads.
')
Maximum anchor performance requires that \he material in
which \he anchor is installed can sustain the load to which
\he anchor will be subjected. Many times, in a prefab build-
ing, you will find layered floors and/or walls containing a
soft core. These suppon structures will require a different
anchor than that used in a solid concrete floor.
The number of anchors used will effect the strucwr.tl integ-
rity of the material the anchors are being installed in. Be-
cause of this. it is recommended that the anchors be spaced a
minimum of ten (10) times their diameter.
Wi\h top-heavy equipment mounted to different forms of
flooring, safety is a major concern. Equipment shall be
bolted to \he floor using bolts that are large enough to handle
vector forces induced by rack movement and equipment
weight. These bolts shall be torqued according to Table 2-1.
Table 2.1: Torque Specirlcations
Bolt TteadsI Torque:
Diameter Inch Grade 2 Grade 5
1/4" 20 66 in. lbs. 8 ft. Ibs.
1/4" 28 76 in. Ibs. 10 ft. lbs.
5/16" 18 11 ft. lbs. 17ft. lbs.
5116" 24 12ft. lbs. 19 ft. Ibs.
318" 16 20 ft. Ibs. 30 ft. lbs.
318" 24 23 fL lbs. 35 ft. lbs.
7/16" 14 32 ft. lbs. 50 ft. lbs.
7116" 20 36 ft. lbs. 55 ft. lbs.
1/2" 13 50 ft. lbs. 75 ft. Ibs.
1/2" 20 55 ft. lbs. 90 ft. Ibs.
9116" 12 70 ft. lbs. 110 fl lbs.
9116" 18 80 fl lbs. 120 fl Ibs.
518" 11 100 fL lbs. 150 fl Ibs.
518" 18 110 fl lbs. 180 ft. lbs.
3/4" 10 175 fl lbs. 260 fl lbs.
3/4" 16 200 ft. lbs. 300 fl lbs.
.
"
.
2-4
MOTOROLA NA T10NAL SERVICE
(Change 1)11119\
". BUILDING AREA SPECIFIC A TT"NS
,
(2) Lighting Fixtures:
Minimum Levels = 0
(off 90% of the time)
Maximum Levels = 100 foot candle illumination
(3 foot level at front and back of each rack of
equipment).
Note: Lights per KWHR = 3.415 BTU/hr.
(3) Exhaust Motor:
Minimum Value = 0 (off 50% of the time)
Maximum Value =.1.700 BTU/hr.
(heat panially vented along with
exhausled air).
(4) Human Occupant
Minimum Value = 0
(unoccupied 99% of the time)
Maximum Value = 700 BTU/hr.
(assume single technician in building).
(5) Solar Effect
Minimum Load = 0
(cloud cover & darkness)
Maximum Load = based on ASHRAE principles.
-\
(6) Air Handling S ystcm:
Air make-up assumed at 10% lOtaI volume
Maximum air inlalce velocity = 500 FPM
(limit water inlalce and noise level)
Maximum duct pressure drop = .08 inch
water/loo feet
Maximum duct outlet grilltempcrarure =
65 degrees F.
Notes:
I. The final air conditioner size shall be determined by
the insulation materials utilized in collS1nlction. plus
the calculated air infiltration and exfiltration vo-
lumes. For a typical building, one (I) ton per 300
square feet shall be a minimum.
2. The battery system' s environment shall be main-
tained and cootrolled at 70 degrees F plus or minus
10 degrees F.
3. Anti-static provisions shall be employed 10 elimi-
nate damage by static elecaicity to sensitive com-
ponents at relative humidity levels below 20%.
4. In areas containing a high concentration of elec-
tronic equipment. air conditioning may be required
during the middle of winter. even when outside
temperatures are sub-freezing. In situations such as
this. a typical window unit will freeze and become
inoperable.
12.3 EXHAUST VENTILATION (DEPENDENT
UPON SITE CONFIGURATION)
(I) Baaery room non-sparking exhaust sySlCm shall be
timer controlled for aUlOmatic isolaled vcnting. All
louvers and dampers shall be motol'izcd and inter-
faced with the control system. The systcm shall be
sized 10 exchange the room air four times per hour.
(2) Generator room inlalce duct louvers shall be mOlOr-
ized and interfaced with the engine slalt/SlOp con-
trol.
(3) The equipment hardware room vcntilation shall be
both manually and thermo-statically controlled. All
louvers shall be mOlOrized and integraled with the
exhaust motor controls.
(4) The air velocity shall be Iimitcd 10 20 FPM in the
conditioned space 10 limit noise levels and the ob-
jectionable actions produced by strong air movc-
menL
(5) The air pressure drop through the dueting shall be
limiled to .08 inches of water per 100 feeL
(6) Mechanisms shall be provided on all air inlalce
ducts to exclude air impurities and limit the particle
density inside the building to a maximum level of
0.5 micrograms per cubic fOOL
(7) All vents and inlalcetcxhaust louvers shall be pro-'
vided with hoods 10 shield the openings from the
weather elements and 10 maintain security against
vandalism.
(8) Manual override control shall be provided 10 actu-
ate the system to clear odors. smoke. and other con-
ditions.
(9) The equipment room ventilation sySlCm' s aUlOmatic
control shall be set to "active" at a temperawre of
five to ten degrees F above the air conditionerl
heater system set poinL The ventilation system
shall be sized for four (4) air changes per hour.
Outlet duct openings shall be of sufficient cross
section 10 convey the required volume with a maxi-
mum velocity of 800 FPM.
RS6(Change I)
QUALITY STANDARDS. FNE Installations, Vol. I
2- 7
2. Bt. . ,DING AREA SPECIFICATIONS
13. EQUIPMENT SERVICING
.J.l CLEARANCE
Minimum service clearance on the equipment is 36 inches in
front and 30 inches in back. This is to allow for easy access
for service and additional personnel. On many occasions,
however, the room layout changes between the date the site
was designed to the time of the aCblal installation. If plans to
relocate the equipment include placing the equipment in an
area where serviceability is jeopardized, field personnel must
notify the project coordinator to request funher instructions.
If a satisfactory solution cannot correct this issue, then the
reasons why such a condition exislS must be documented. If
these procedures are not followed, the installation workman-
ship will be repeatedly brought to the maintenance
technician's attention, each time work is performed on the
effected equipmenL
13.2 ACCESS
Installation personnel must make every effon to avoid siw-
ations in which cable trays have to run through another area
in a facility occupied by another customer and requiring a
separate key and/or permission to enter.
I "'hen cables pass through a wall, the hole will be sealed to
allow for environmental conb'Ol and to prevent the spread of
fire and/or gasses. A good example of this is having the
batteries located in a nearby room. By code, the battery
room must confine a fire for a minimum of two (2) hours.
14. TELEPHONE OR MICROWAVE
COMMUNICATIONS
Telephone or microwave communications at equipment sites
is very imponant for safety reasons, as well as for perform-
ing maintenance and b'Oubleshooting. To ensure the safety
of personnel, especially when only one person is working at
a remOle location, two-way communications must be avail-
able at all times. For maintenance and b'Oubleshooting, a
tclephone or microwave link is invaluable when there is a
need for the local technician to be able to contact a central
suppon group and/or computer in order to obtain help. Many
new systems also require a communications link to down-
load the operational information in order for the equipment
to function. With the above reasons in mind, a two-way
communications link is required for all equipment sites.
15. BATTERY SAFETY PRECAUTIONS
Batteries present a wonderful solution to system suppon
problems during times of unsatisfactory commercial power;
however, they increase the number of safety issues that must
be considered. Battery rooms must be sealed to prevent the
spread of gasses and/or fire. By code, these rooms must
confine a fire for a minimum of two hours.
')
Provisions must also be made to exhaust gasses given off by
these batteries. The correct stationary battery llame-arrest-
ing vent must be installed on each cell. This vent must be
secure, clean, and in repair to ensure maximum proteCtion
against potential explosion. Two methods may be used to
vent battery gasses. One method is to use an exhaust fan on
a timer. The other way is to use a manifold system that is
comprised ofPVC wbing (see photo. 2-3). Whichever method
is selected, the air must be exchanged four times per hour to
vent off the excess hydrogen gas.
"No Smoking" signs shall1le displayed in the battery room.
Smoking, or the source of any spark-producing materials, is
strictly prohibited in this area (see photo. 2-3). This must be
enforced as an explosion may result due to battery vapors.
A non-sparking circuit breaker of adequate size to handle the
DC current produced by the battery system and ilS load must
be installed (see photo. 2-3). This allows lhe batteries to be
removed from the charging and load circuilS during battery
servicing.
.
.Since all commercial batteries contain acid in one form or
another, it is necessary to prolCCtthe lloor under the batteries
from damage should a battery leak. Safety material must
also be present in order to protect personnel from acid bums.
Full face shields and eye wash solution must be present at
each site containing batteries of any 1cind. Rubber gloves
and apron must also be available when working with any
type of large commercial battery.
,
Due to their size, weight, and service needs, batteries are
normally installed on shelves or racks; however, in eanh-
quake-prone areas, seismic racks will be used. Racks and
shelves must be constructed to suppon the total weight of the
batteries and other supporting equipment placed on them. A
means of preventing the accidental movement of the batter-
ies that could cause them to fall must be implemented.
.
2-8
MOTOROLA NATIONAL SERVICE
(Change 1)1/1191
.. BUILDING AREA SPECIFICAT"NS
The two suggested methods are as follows:
)
I. lnslaIl a rim around the batteries to prevent tipping.
2. InlelConnect the batteries to prevent movemenL
Racks must be bolted to the floor or waU, and, although the
ballCries may electrically float, the rack. if metallic. must be
grounded as per Motorola grounding specifications. The
standard metal rack, by design, also confmes the total weight
of the batteries to a small section of the floor. Because of
this. exaa care must be raken to ensure the solid SU'UCture of
the flooring can handle the weighL Placement of lhe baller-
ies must also prevent direc:t sunlight from heating the ceUs.
,11;"
q
I
:.~~~i.. :j~~:-~~:'-'
1" ." . '< ~"""
! 'c+;.;c~'~J2. J
.~.u U 11 [},,,";;~~\:~-:~J....,~ 1
\'i:~~.:i .:; '.
~.~~-'"
.~~~""
;:~~j~:':'-
:::.4 it,?"
(J rn D .; .'
. .~_ ,:~:..C..'
.c".=4G-.4 --
~.:;~ ~
" j1' 'I
J
" ~
~
,"
r " .. II :n
.
I J
!
Photograph 2-3: Example of a well installed baucry
system. Observe the "No Smoking" sign and lhe venting
system.
Usually, the selection of the type and size of the batteries will
be derennined by C\lSlOlllCf preference and system parame-
ters on an engineering basis.
Unless otherwise specified, the battery system selected, for
mOSllarge applications, will either be the flooded lead-acid
type or the lead-calc:ium type. These battery cells have been
generically known as "wet" cells. Handling "wet" cell bat-
lCries requires that close attention be paid to the weight and
corrosive content of the cell.
Newer battery lCChnology uses a sealed, rechargeable lead-
acid battery. These sealed units are genericaUy known as
"dry cells" or starVed elecuolyte. Using "dry cell" batteries
requires that close attention be given to the weight of these
units.
Note: The gassing rate is dependent upon charging
time, temperalUre, and elevation.
Table 2-2: Battery Accessories
Required OD Site
(l). Connector bolt wrench (non-conductive)
(2) Lifting sling and spreader block
(3) OSHA approved emergency eyewash kit
(4) Rubber gloves, apron, and face sbieId
(5) Container of baking soda to neuaalia spilled acid
(6) Container of non-oxidation material for coatiDg
eleclricai connections
(J). Hydrometer with markings every 10 poinlS
(8). One acid-resistant container for SUlriDg lhe
hydrometer
(9). Thennometer, Battery.
Note: ..." denotes items required for lead-acid
baucry use only.
16. NATIONAL AND LOCAL CODES
In all cases, procedures, worIanansItip, aDd maIaiaIs must
follow or exceed those specified in the National ElecIrica1
and Safety Codes. Local codes will also be followed at aU
times to ensure an acceptlIble jro...n.rinq.
Note: For syStems that have batteries installed, special
attention must be given to national and local codes
to cosure compliance. <
R56(Change I)
QUALITY STANDARDS. FNE Installations, Vol. 1
2-9
2. BU.- DING AREA SPECIFICATIONS
17. ANTENNA PLACEMENT
..tcnna mounting shall be per the manufacturer's instrUc-
lions. All antennas shall be placed according to installation
cnginccring information supplied by Motorola.
Table 2.3: Antenna Separation -
Minimum Standards
System Vertical Horizontal
(in feet) (in feet)
Trunk 5 20
Ccllular.
OmnilOmni 3 12
OmnifSector 0 12
SectorfSector:
Receive Antenna 0 8
Transmit Antenna 1 3
The installation hardware supplied by the antenna manufac-
turer shall be used unless Motorola is supplying special
brackcts for unusual mounting.
When applications require special orientation such as in
cellular and microwave installations, special attention must
~': lakcn to verify that alignment and separation rules are
,ing followed.
I Note: The antenna installation team must be sufficient to
perform the task at hand. These personnel must comply with
proper install techniques and safety policies.
17.1 PHYSICAL ALIGNMENT PROCEDURE
r)
A portable hand compass for verification of direc-
tion and magnetic north will be needed.
(2) To assist in establishing the remote landmark posi-
tion for the required antenna back azimuth verifica-
tion, a good large-scale topographical map of the
location, with seven and one-half minute markings,
wi II be needed. When antennas are mounted on
existing buildings, a building site plot plan would
be helpful in establishing the building reference
direction.
(3) Two (2) portable communications radios will be
needed for coordinating activities between the
ground and antenna locations.
I (4) To prevent damage to boiLS and antenna hardware,
the site supervisor must insure that the antenna
installers use the proper tools for the task at hand.
~
18. TOWER ASSEMBLY
The vendor supplying the lOwers will supply an installation
specification manual with each tower. It will be the
subcontraCtor's responsibility to follow this manual's in-
structions. If a problem occurs preventing this action, the
subcontraCtor must notify the Motorola project coordinator
immediately beCore continuing work. With this in mind,the
Motorola personnel overseeing the subconlnlCtor must com-
pletely understand this manual to ensure long-term reliabil-
ity. IC the tower manufllClUla' offers an installation aaining
school. the contraCtor should have one oC his or her job
supervisors attend the program and lhis person should be on
the job during the critical stages oC tower installation.
Motorola shall be responsible for tower design, including
selecting the correct tower to suppon the antenna loading Cor
both the present and estimated Cuture needs. Motorola will
also supply the Coundation design and perform the soil test-
ing for each site. Zoning and permits are normally the
customer's responsibility; however, in special cases. MOtor-
ola can assist in obtaining the necessary approvals.
.
The selected tower subcontractor shall be responsible Cor all
activities relating to tower erection. This shall include foun-
dation and pier excavationfconslnlCtiOll. steel em:tion, paint-
ing and lighting (where required). and grounding as per
Motorola specifications (see Chapter 4). Antenna and line
installation will also generally be included in this subcon-
tract. All subcontractors will be expected to dispose oC any
reCuse material and level any ground that was excavated
during construction.
I All towers must comply to the latest ElA Standard, RS-222;
FAA. Standard, subpart C, part 77; and local building codes
as a minimum acceptable level.
19. BACK-UP GENERATOR TESTING
The main purpose of a back-up generator is to supply reliable
power to a critical load during emergency conditions. It is
very important to the operation of the electronic equipment
that the generator be completely tested before the new load is
.
2-10
MOTOROLA NATIONAL SERVICE
(Change 1)l/ll9t
., BUILDING AREA SPECIFlCATV'NS
placed on it and at periodic inlerV8is after the initial check-
ouL This initial checkout shall be performed before the new
~ cquipm~nl is activatal. CiCllCllltOlS will be leSICd witbow
the load to ensure Ihat vol rage and f'rcquency oUlpllts meet
load specifications (refer to the vendor supplied documents).
The lrlIIISfer switch must have a means of delaying the load
lI'aIISfer to allow the motor to stabilize. This means the
system will be off the air for a short period of time unless a
battery sySlem is employed. Failure to bave an adequate
delay will result in unpredictable generator oulplllS. This
could cause damage to the e1C(:1roIIic cquipmenL
Notes:
I. All attempts shall be taken to stabilize generator loads
(i.e.. tower beacons ba1Iast load).
2. All neutral lines shall be in separale conduit at the
lI'aIISfer swilCh location.
QUALITY STANDARDS. FNE Installations, Vol. 1
2-11
R56(Change 1)
2. BlITLDING AREA SPECIFlCA nONS
This page inlClltionally left blank
MOTOROLA HA TlOHAL SERVICE
2-12
(Change 1)1/1191
~
(
.
-~.
.
3. CABLING
'"
1. SIGNAL, POWER, AND GROUND
CABLE SEPARATION
In parallel runs, signal, power, and ground cables CTable 3-1)
must be separated by a minimum of duee (3) inches. At
inlCl'SCl:tions, the cables will be run as cIoscly to ninety (90)
degrees of each other as possible. These requirements are
based on the knowledge that high eIeclricaJ energy can be
induced from one cable to another, especially during alight-
ning hiL When different types of cables are separalCd, the
likelihood of energy traveling down a ground wile and in-
ducing a voltage to a signal line will be gready reduced. This
is not a guarantee that lightning damage will be eliminated;
however. it is part of the necc:ssary requirements to keep the
damage to the minimum.
Table 3-1: Types of Cables
(1) R.F. anlCnna lines
\
(2) Power
a. AC
b. DC (twice the size per amp. as AC)
(3) Signal
a. Audio
b. Conuol
c. Digital
(4) Grounds
2. POWER AND GROUND
CONNEcrIONS
As the temperature and humidity changes, the wile and other
components expand and conll'llCL These changes will cause
a tight connection to loosen over a period of lime. Ground
lugs must be inspecled for tighllleSS immedialCly following
completion of the instal1ation. 30 days after completion. and
during scheduled preventive mainlCnance.
3. SIGNAL CABLE AND ANTENNA
CONNEcrIONSEC~Y
Loose connections can resldt in a number of problems dtat
can range !ran an easily detected malfunction to an inlCllllit-
lCIIt problem dtat is difficldtto duplicalC. Most connections
are locaIed on backplanes, tmninaI blocks, or tcIco blocks
and should be kept tighL If more lime is speDt in ensuring
tight connections, a reduction in service caDs will resuIL
4. CABLE SELECTION
Due to the different types of terminations available to eu5-
tomer5, it must be ensured that the cable used to in_t
the components is suited for the job. lnslaIlers and supervi-
sors must insure dtat the cables that are delivered with the
syslCm meet the customers cunent and future needs. Con-
tinuous dialog with the customer and the system engineer
willeliminale any misunderstandings.
4.1 SOLID WIRE
Solid wile is to be used when the elec:tricaI c:onnection is
made by having a pin cut into the wile itself. This may be
accomplished with either punch clown or wile wrap connec-
tors; the sharp edge of the pin cuts the wile to make the
eIecDicaJ and mechanical connection. This type of cannec...
tion fatigues the wile, however, and can only be used once.
When a solid wile is removed from its connecllll" pin, the old
wile end must be cut off and the insu1aIion sDipped back to
expose a new section of wile. Because of this, it is a genenl
practice to leave a duee to five inch service loop in cross-
connect wiring, especiaJly for longer runs.
4.1 STRANDED WIRE
Stranded wire should be used when flwbUity is imponanL
or where compression connections are to be made. An
example of this is a lug crimped to a wile that is connected to
a screw type lCnninaJ block. Unfonunarc!y, silU&tions arise
R56(Change I)
QUALITY STANDARDS. FNE Installations, Vol. 1
3- I
3. CABLING
which require the connection of a solid wire 10 a screw-type
lerminal block. When this occurs, there arc two options
~ilable. The rlJ'St choice is to simply wrap the solid wire
Jund the screw. The preferred method, however, is 10 use
a crimp-on lug, but after compressing lhc lug, a small amount
of solder must be applied to ensure a durable physical con-
nection.
4.3 SHIELDED WIRE
Shielded wire shall be used on circuit paths where induced
noise can jeopardize system performance. When shielded
cable is in use and the cable is not terminated with a connec-
tor, the signal carrying wires will be terminated as per the
above specifications. Grounding of the shield wiIl be ac-
complished at one end only, and this must be consiStent
throughout the installation.
5. POWER CABLE SIZE
Care must be taken when selecting the size of the cable to be
used because a fire hazard could exist. Refer 10 Table 3-2:
Power Cable Size, for details.
I
Table 3.1: Power Cable Size
COPPER CABLE
(AWG)
DC MAX.
CURRENT
AC MAX.
CURRENT
14 ....................... IS ........................ 7.5
12....................... 20......................10
10.......................30...................... IS
8 ....................... 4S ...................... 22.5
6 ....................... 6S ...................... 32.5
4 ....................... 8S ...................... 42.5
3 ..................... 100...................... SO
2 ..................... 115...................... S7.5
I ..................... 130...................... 6S
0..................... ISO...................... 75
00 ..................... 17S ...................... 87.5
6. CABLE DRESSING AND FASTENING
Cables need 10 be dressed in a manner that allows for easy
servicing, yet still looks neat in appearance. The actual
number of ties needed will vary due 10 the distribution sys-
tems being used, the size and type of cables being used, and
the number of turns the cables arc required 10 make. When
cables arc run inside a building, a tie shall be used to allach
the cable 10 a stable object every three (3) feet, where the
cable sags one-quancr inch or more, or where movement
could eventually fatigue the metal and damage the cable.
""
7. TRANSMISSION LINE USAGE
Transmission line usage will be directly dependent upon the
line length and E.R.P. parameters designed into the systems
(Table 3-3).
Table 3.3: Typical Transmission Line Usage
Diameter Length
1/2" up 10 6S'
718' up 10 I1S'
I SI8" over I1S"
.
8. TRANSMISSION LINE INST ALLA TION
Towers must suppon multiple antenna lines, and at one
pound per foot for one and five-eighths inch line, these lines
arc quite heavy. Therefore, antenna line cable load must be
equally distributed among the lOwer legs. care must be
taken 10 ensure that the lines arc properly routed and sup-
poned, using the appropriate attachment hardwarc, from the
lOp of the lOwer to the equipment location.
For tower installations, aansmission lines shall be secured at
one foot intervals for the rlJ'St three feet at the lOp of venical
runs and thereafter at three foot intervals using supplied
matcrials. Make certain that the transmission line cable is
fastened so that its weight is supponcd independently from
the antenna. There must not be any strain on the antenna
connector.
"
I Foam Heliax shall be attached 10 supporting structures with
tie-wraps which arc designed for outdoor use, manufacwrer
supplied fasteners, or stainless steel butterfly clamps.
.
3-2
MOTOROLA NA TlONAL SERVICE
(Change 1)"1191
3. CABLING
~
INot all lines will be foam filled. If lines are air filled.
consideration for air dehydrator equipment or inert gas pres-
surization must be included in sire deWIs. The air dehydra-
lOr shall not be mounted in equipmentlllCks -....v the vi-
bllltions can have III adverse effcct on the equipmenL Cllll~
suit the system engineer for placement of pressurization
diSlributicin manafold(s) and associated air monilOringllld
regulating devices. .
Gun or hammer driven staples are not recommended fill' use
with lilY lIllIISIIIissillllline. They lend ID crimp the cable and
may crack inremaJ insularors or cause slight cable fractun:s.
Pressure leakage, internal shaning,lIId characteristic imped-
ance changes may result from their use with air line.
When cable nms must be secured ID masonry, metal. 01'
wood walls, where the use of nylon tics is implllClical. mount-
ing SlIllps may be used. Care must be taken so lhalthe ower
dimension of the cable is not distoncd by mOUDting SlIllp
pressure. The cable may be taped with vinyllapc "".......'h the
fasteners ID give added protection against crushing.
Fasteners must hold the cable funlly in place. Where practi-
cal. use I'asleners so lhal the COlIltiaI cable is supported
agaillSl the fla1 side of the mounting SlrUCIUre ID disaibure
pressure over as large III area as possible. Under no circum-
stances will lilY type of coaxial cable be allowed free move-
ment from wind or lOwer vibllltion. Metal fatigue IIId u1ti.
mare breakage can rcsuIt from even ntinor flexing of solid
dielcctric cable at the point of fastening.
Additional support is required for lines with long horizontal
runs. If runs are grearer lhIII IS feet in length. a support
StruClUre, such as an ice bridge. must be installed. This will
provide the lines with nccdcd prorection and support against
wind. snow, and ice. Once installed. the support SIrUClIIn:
must be bonded ID the system ground Ilthe building end.
Suppon for runs shonu lhIII IS feet is optional.
Care must be taken so Iincs are not kinked or bent at sharp
angles. The bendingllldius shaII be no less lhIIIlO times the
line diamerer. Lines shall be brought inID the equipment
enclosure per methods specified in the insr.aIIalion docu-
menlS with all enlly poinlS wcalhcrproofcd. Drip loops shaII
be incorporared in the nms ID prevent warer from aickling
down the lines inID the building. Lines must be run 10 the
equipment area specified by the Motorola installation docu~
mcnlS and rerntinared with the proper RF connector. When
lines are run underground (i.e.. under a road or parking lot), it
shall be verified lhalthe conduit is warertightlO prorectthe
cable.
,
Towers and anrenna lines near the ground shall also be
prorected from damage by both aUlD and foot traffic.
Special at/ention must be given ID anrenna lines ID reduce the
possibility or Iighating damage ID equipmcntinsidc the buil,
ing. Tlllnsmission lines must be grouncIcd Ilthe lOp of It
vertical run and as tiDes cnrer lbe IluiIdiq. U lbe 1Iorizool:
run is more lhIII nfleCll feet. an additional ground kit shall t
installed on Iincs Ilthe lOwer's lowermost cable supporL
All ferrous mcraJs used as put of the i1'''.II.~ shall be hot
dip galvanized 01' ...;"Iess su:c1. All saews, boilS. lac
washcn. and nulS shaII be SlainIcss steel, brass, 01' hot-dr
galvanized.
9. ANTENNA JUMPER INSfALLATION
Anrenna jumpers are casiJy c1amagcd, IIId care must be taker
when worldng with them. A tight lIInI will kiak the OUIC:
shield and change the reflected power IoId being prescnte<
ID the equipmenL The shield can aIIo sIIClIt into the CCDIC'
conductor and shunt the entire signal. In tight silllations or
w~ the dressing will be more IllIllCtivc 01' pnllCCtive o.
the cable, ninety degree COIIIICClIlrS will be used lD prevcn
lhcsc problems. When insralling llltenna jumpers, lb,
manufacllRr's bending specificatiotts must not be violated.
since this pncticc degrades sysrem performance.
Table 3-4: Superflex Cable BeDdiq Specil'acatioDS
Jumpel'Diameter Min. Bending Spec.
Ifl. .________..___ 1,25.
1/4. ._____....___...._ 1.00.
10. CABLE LABELING
To aid in fUllln: troubleshooting. each cable must be labeled
Il both ends with a realistic: mCIIIS of idcDtiflC3tion. Labels
used must be permanent and professional in appcar.lDCC.
Table 3-S: SlllIlIcsred Cable Labeling Techniques show
sullllcstcd mclhocIs for labeling the various cables one is
likely ID cncounrer Il a sire.
RS6(Change 1)
QUALITY STANDARDS. FNE Installations, Vol. 1
3- 3
3. CABLING
Table 3-5: Suggested Cable Labeling Techniques
~ _Jle Diameter Labeling Method
< 112"
> 112"
Use a tie-wrap with a flag molded 10 it
Use a nylon tag with a hole at each
comer and secure it around tbecable jacke
using standard tie-wraps.
any size
Use numbered stickers.
The contraClOr shall clearly mark each uansmission line with
tower height and antenna model number. In addition, a
hand-drawn diagram shall be given to the MOlOrola project
coordinator showing tower height, antenna orientation,length
of each transmission line run, and the model number of each
antenna.
11. CROSS-CONNECT BLOCKS
11.1 SELECTION
Cross-connect blocks (C66 type, 25 pair; Motorola pan
number 01-83652P01) are normally recommended to stan-
~-'dize cross-connect block installations. This unit can be
unted on a distribution frame, equipment rack, or wall-
mounted plywood. Cross-connect blocks allow for the punch-
down connection/termination of standard 25 pair,telco-style
cable and is equipped with the necessary shoning clips. In
special cases, like physical needs or customer request, other
rorms of cross-connectterminations may be substituted.
Note: If the above mentioned cross-connect block is used,
a standard C-66 punch-down tool is required.
11.2 INSTALLATION
On large systems with six (6) or more blocks, it is advisable
to install the blocks on a distribution frame like those used in
lhe telephone industry. The use of these distribution frames
allows for a more professional installation where fewer prob-
lems will be encountered.
In smaller systems, where the cost of distribution fi'ames
exceeds budgetary allocations, a three-quaner-inch thick
plywood sheet shall be used to mount the blocks. The sheet
shall be of adequate size to allow for proper spacing and
r Ulure expansion. The plywood will be wall-mounted at a
convenient location to allow for adequate service clearance
and minimum cable lengths. The mounting of the blocks
shall also allow for easy installation and servicing (PholO-
graph 3-1).
.,
Photograph 3-1: These cross-connect blocks are wan
mounted to a plywood panel. Notice how the spacing
between the blocks allows for servicing.
(
.
11.3 LABELING
Like cables and major equipment items, cross-connect blocks
in the system must be identified. Labels used will be perma-
nent, professional in appearance, and provide high contraSt
with the background to which they are affixed. Individual
circuits on each block shall be labeled in a neat fashion using
indelible ink.
J-
12. WIRE WRAP CONNECTIONS
A connection with too few wraps may result in poor electri-
cal contact; however, too many wraps will prevent the addi-
tion of more wires. For this reason, six to eight complete
turns are required on each pin. Bare wire must not be
exposed in such a manner as it could possibly shon to
adjacent pins or signals. When a wire run is tight, bends
around comer pins will be avoided since these pins can cut
through the insulation. Refer to Table 3-6: Wire Wrap
Standards for more detailed information.
.
MOTOROLA NA TIONAL SERVICE
34
(Change 1)111191
"'
4. GROUNrTNG AND BONDING
1. GENERAL
The pUlpOSe of Ibis chapteI' is ID eslab1ish IeChnica1 guidance
for inslalling a grounding system which will provide person-
nel and equipment lighming proleCtion. and minimize in-
duced noise and SIalic_ Utilization of Ibis document in
system design must be in conjunction willi the National
Elecll'ica1 Code and allloca1 grounding-rdaled buiJding codes
(which would supersede dlis document). Protection of elec-
tronic equipment and penonnelID the natural phenomenon
of lighllling demands a dIorough evaluation of each individ-
ual system requiIements. The precautions will influence the
lightning environment ID which a sySlem and equipment will
be exposed. The degree of proleCtion will deu:rmine the
severity of a direct lighming saike's potenlialJy damaging
effects.
2. ASSUMPTIONS
s
It is assumed lhroughout dlis standard 1hat llIe soil inID which
a grounding system is ID be established is of average resistiv-
ity and 1hat sub-surface fonnations do not prevenl ground
rods from being driven ID die depths specified. If local
conditions prevent the above assumptions from being met.
special engineering for a grounding sySlem will be requiJed.
The reference documents lisled in Section 12 (i.e.. National
Elecll'ic Code. Bell Telephone Specifications. etC.) should be
used in deu:rmining the special requirements.
3. SPECIFICATIONS
3.1 GROUND RODS
IA copper-clad steel rod widl a minimum Ienglll oC eight (8)
Ceet and a minimum diameter of SJ8 inch will be used. The
actual size. length. and number of rods used will be deler-
mined by soil resistivity/composition as specified in Chapler
1. Page7. Paragraph S.
3.2 CONDUCTORS
These are the wires which connect ground nxIs IDgether.
Corm ground rings. and allow connection of objects ID be
bonded ID the grounding syslem. StrapS/ban may be used as
long as the cross-sectional area equals or e~ceeds 1hat oC the
. specified wire.
3.2.1 Conductor Types
(1) Below Ground
I = copper wire. Tinned solid copper wire will be
(2) Above Ground
Solid or sll'lllded copper wire. lnsulaled wire must
be used when runs are in cable nys. and is optional
when used for olher above ground applications.
3.2.2 Conductor Sizes
(1) Below Ground
112 A WG minimum.
(2) Above Ground
L For ground rings and connectioo of internal
and external ground rinas.1I2 A WG minimum.
b. For grounding oC equipment and specifIC mellll
objects. 116 A WG minimum. 112 preferred.
c. Specific recommendations for larger conduc-
lDrS are noted 1IIIdec specific circumstanCeS.
3.3 CONNECTIONS
3.3_1 Genenl
Where connections are made using a lug or clamp. the con-
tact points are ID be cleaned and made free of foreign mate-
R56 (Change I)
QUALITY STANDARDS. FNE Installations, Vol. 1
4-1
4. ROUNDING AND BONDING
rial. such as paint and corrosion, to ensure an adequate bond.
"pplication of an anti-oxidant compound is recommended
NO-OX" or equivalent). In order to maintain a good bond.
lugs with two mounting holes should be used to prevent the
pivoting and loosening that is inherent in lugs with only one
mounting hole. Using star washers. auach the lugs to the
equipment racks. cabinets. elC. with the appropriate number
of fasteners. The objective is to provide a good electrical and
mechanical connection that will Slay that way!
3.3.2 Above Ground
(I) Conductors:
One of the following methods must be used when
two or more conductors are to be joined: exother-
mic welding (Cadweld or equivalent), or pressure-
type crimp connectors(12 tons or better). bolted
clamps. or split bolt connectors. Crimp connec-
tions are not recommended on solid conductors. If
mechanical connections are being used for above-
ground bonding, these connections must be ''PM' ed"
for tightness and corrosion prevention. Time be-
tween PMs shall not exceed six (6) months and may
be performed more often if desired.
(2) Connection to Equipment:
Connection of conductors to equipment shall be by
use of lugs or clamps appropriate to the size and
type of wire and provisions of the equipment being
grounded (Figure I).
3.3.3 Below Ground
All connections must use the exothermic welding process. or
pressure-type crimp connectors (12 tons or betlCf)
4. GENERAL PRACTICES
4.1 GROUND HALO
Internal and external grounding systems will be connected
together to form a "ring" (encircling the building or equip-
ment area to be grounded).
4.2 CONDUCTOR BENDING
"harp bends in conductors are to be avoided.
4.3 DISSIMD..AR METALS
Copper conductors must not be installed on aluminum roof-
ing/siding/cable trays/elC.. due to corrosional problems. Alu.
minum conductors must be utilized for these areas. with
proper bimetallic transition connectors between aluminum
and copper. All aluminum conductors shall be two sizes
greater than that specified (e.g.. use #4 A WG instead of 116
A WG). The use of an anti-oxidation compound is recom.
mended.
"1
S. EXTERNAL GROUNDING SYSTEM
5.1 BUD..OINGS
5.1.1 Positioning or Ground Rods
The grounding system around the exterior of a building will
consist of a ground rod at each comer of the building and
rods as necessary to reduce the distance between rods to IS
feet (Figure 2). The rods shall be driven. using the proper
tool to prevent rod deformation, to a minimum depth of 30
inches below finished grade (NEC 2S0-81d). The rods are to
be placed approximately two feet from the building founda-
tion (Figure 3).
.
5.1.2 Forming tbe Halo
The ground rods must be connected together as outlined
under Sections 3 and 4.
5.1.3 Entrance to Internal Grounding System
"
Provision must be made for entrance to the building's inler-
nal grounding sySlCm. This will be accomplished by placing
a PVC (plastic) pipe through the floor to allow a #2 A WG
wire from the external grounding system to enler the build.
ing for connection to the inlCmal grounding network. Metal
conduit is allowable as long as the ground wire is bonded to
the conduit ends. These entrances shall be provided adjacent
to each ground rod (see Figure 3).
5.1.4 Ground Test Well
I A ground test well shall be provided for measuring ground
resistance. This can be a section of 6" PVC pipe placed over
ground rods in alternate comers. A cover is to be used to
keep din from the pipe (Figure 4).
.
4-2
MOTOROLA NA TlONAL SERVICE
(Change 1)11119\
~. GROUNDING AND BONDING
5~ ANTENNA TOWERS
) The antelllla lOwers must be bonded 10 the external ground
system (PholOgraph 4.1) using anyone of the methods used
in Para. 3.3.2. Most lOwer manufacturers will not allow
Cadwelding directly 10 the lOwer leg; however, they do offer
an alternative source but must be specified at the time of
purchase. These kits must meet the current Motorola ground-
ing standards.
.)
PholOgraph 4-1: The ground conductors are bonded 10 the
lOwer base by the Cadweld method. Some lOwer
manufaclW'erS supply a plate (bottom) for this purpose.
5~_1 Monopole Masts
Monopole masts will be grounded with a minimum of three
ground rods, connected IOgether as specified in Sections 3
and 4. Four ground rods are recommended as shown in
Figure 6.
5~~ Lattioe Towers
Lanice lOwers must be grounded with a ground rod adjacent
10 each lOwer leg and connected together as specified in
Sections 3 and 4 (Figure 5). If the distance between ground
rods is more than IS feet, additional rods will be used to
reduce the distance between rods 10 IS feeL This means if
the rods are 16 feet apart, a rod will be driven midway be-
tween the two lOwer leg rods. A 112 A WG (tinned solid)
copper wire will be connected 10 this grounding system and
10 the lOwer leg, as specified in Section 3. A connection
must be made 10 the building external grounding system de-
scribed in Para. 5.1 above by a minimum of one conductor.
5.3 GUY WIRES
Each guy wire will be grounded at the anchor poinL A
ground rod will be installed at each guy anchor and wire con-
nected as in Sections 3 and 4 (Figute 5). A 112 A WG (tinned
solid) copper wire sha1l be connected 10 the grounding sys-
tem 10 each of the guy wires as specified in Sedion 3.
5.4 CONNECTIONS TO THE EXTERNAL
GROUNDING NETWORK
The foUowing is a partial1ist of itemS which should be
connected 10 the external grounding system; those which are
foUowed by an asterislr: (*) IIIIIS be grounded:
1. Any metal fence wiIbin six feet of the ex1elll8l
grounding nelWOIIt. QI' any grounded objllcL *
2. The lrlII'....inWt \iDe entrance batch, if metallic:.
Minimum conductor size 112 A WG. *
3. Metal building pans DOl grounded by the intemal
ground ring, such IS downsponIs, siding, etc..
4. Metal fuel sunge llIDks, above or below ground. *
S. GrouIId rod or rods p'Clvidcd by the power or
te1epbone utility for grounding of AC ponnd or
prottJCtorS. when pennilIed by local codeL
6. Any significant metal object within six feet of the
external grounding system or any odIer JIIlIIIIded
object (i.e., generaJDr). *
7. Building skid or pi<< foundation IIlCbon of pre-
fabricaIed bui1c1inp.
g. Ex1l:rior cable lIlIY and ice sbieIds. *
9. Generator and support skid or bale. *
FigtR 7 shows details of typical grounding systemS.
,
RS6(Change 1)
QUALITY STANDARDS. FNE Installations, Vol.l
4-3
~. r:ROUNDlNG AND BONDING
5.5 FE:"CEGROUNDING REQUIREMENTS
Ie fence shall be eleclrically grounded to prevent shock
na7.ard from lightning or other electrical sources as follows:
(I) Ground Rods
A 10 foot long, 5/8 inch diameter copper clad rod
shall be driven into the ground close by the fence.
The top of the rod shall be at least six inches below
the surface of the ground. In rocky areas, shoner
rods may be used or special grounding techniques
may be employed. Each 100 lineal feet of fence
shall have a ground rod with approximate equal
spacing between the rods.
(2) Ground Wire
# 2 solid copper wire shall connect the fence to the
ground rods. Connecting devices shall be made of
non-corrosive materials and shall be inslalled in a
manner to prevent loosening due to vibration. The
exothermic (Cadweld-type) welding process must
be used (Photograph 4-2).
(3) Customer and Motorola Specifications
Special specifications will often define methods of
grounding or connection to existing tower or sys-
tem ground. Such definite specifications must be
approved in advance by the customer or Area Engi-
neer and must be observed.
Photograph 4-2: The fence post is grounded, including
the gate.
6. INTERNAL GROUNDING SYSTEM
6,1 INTERNAL GROUND RING
SPECmCA TIONS
~
An internal grounding system must be provided to allow the
use of shon lengths of conductors from individual equipment
ground to the internal grounding system. The halo syStem is
recommended to be about six inches from the ceiling or 8-10
feet above the floor. The internal grounding networlt shall
be suspended to allow easy connection. One such melhod is
the T & B ''Ty-Rap" S~5A Sl8Ddolfwith TC-15 cable lie,
or equivalent, aaached to the building wall, This ring must
not be concealed to allow inspection. and must not run along
and in close proximity (about 6" minimum) to magnetic
structureS such as ducts or "I" beams.
The ring will encircle the radio equipment and supponing
hardware. Additional side-lO-side conductor runs may be
made to facilitate equipment connection, these being well
bonded to the main ring.
The internal grounding system is to be connected to the
external grounding system as provided in Para. 5.1.3,
Under no circumSlllnceS will the internal ground ring be
connected to the building sprinkler system. Serious damage ...l...
could result due to the low flash point of these s)'StelDS; .
6.2 CONNECTIONS TO INTERNAL GROUND
RING
When connecting equipment to the internal ground ring, the
ground cables must be run in the shortest protected route
(using a cable tray) provided their p1acement does not inter.
fere with other equipment or the safety of personnel. This
allows the ground cables to provide a quick discharge path to
ground. Daisy-chaining RF equipment racks is penniued;
however. the chain should be limited to groups of five (5)
cabinets or less.
,
~
The following is a paniallist of items which must be con-
nected to the internal ground ring (Figure 8):
1. A ground must be attached to a point inion the
repeater equipment, as close to the antenna coax
attachment point as possible (but not cabinet skin).
Vertical mounting rails in a cabinet make excel-
lent bonding points. A #2 A WG copper wire is
recommended.
.
4-4
MOTOROLA NA TlONAL SERVICE
(Change 1)1/1191
4. GROUNDING AND BONDIN""
2. The lI3IISIIIission line enaanc:e baIdI (if melal1ic:).
A #12 A WG copper wire is ra:ommendcd.
,
3. VentiJalion louwrs and/or sheet melal duct work.
4. The cable 113Y systan (multiple connections may
be desirable).
5. The AC power panel enclosure and AC power line
proIeCllln.
6. The rclepbooe terminal block enclosure, rclco
n:peaIa'S. and telephone proIIlCllln. A #12 A WG
COJlP<< wire is recommended.
7. Door frames and doon. Braided or flexible
welding cable is ra:ommended.
8. Any permanent, significant, mew object within
six feet of any olher grollllded object.
9. Mew bauery racks.
10. Operational emergency generatllr (may be
sepanI/.C inrcmal grounding system in generator
room).
"
.'
11. Mew warcr ulility pipes on the street side of tile
meler.
12. TtlUISmitlCrcombincr.
13. Receiver multicoupler.
14. TtlUISmission line grounds and lighllling arrestors
as desaibed in Section 7.
63 CONSOLE GROUNDING
When consoles an: used in a syslCIII. bays will be bonded
together (Pbotogtapb 4-3) and tied to the central electronics
rack with jj(i A WG stranded or larger. The central electron-
ics IlICk will then be attaChed to the sysrcm ground (i.e..
building ground. exrcmal ground, etc.) willi a minimum of
#12 AWG.
.'
Photograph 4-3: The console ground must be applied to the
unit's framework, as shown in this example.
Pbotograph 44: The equipment rack is grounded in this
application. Notice how the rail is used as a grounding
point, not the skin of the cabinet.
RS6 (Change 1)
QUALITY STANDARDS. FNE Installations, Vol. 1
4-5
4. ~ROUNDING AND BONDING
6.4 EQUIPMENT FRAMES AND OTHER METAL
STRUCTURES
Equipment. frames and olher melal SUUClWl:5, adjacent within
six feel in any direction, shall be bonded IOge1her wilh
conduclOrs specifically provided for this purpose. Incidental
palhs tIuough frameworlc. unisuut, cable racks, building steel.
ele. shall JIl:Il be depended on. Solid copper or flexible
slranded cables are preferred (PholOgraph 4-4).
6.5 GROUND WINDOW
e ideal approach 10 a ground system is Ihe use of a single
point ground. The area where all ground COMectiOns termi-
nate is called a ground window. Physically. a ground win-
dow is a copper bar wilh holes for connecting conductors and
is similar in appearance 10 Ihe external ground bar shown in
Figure 9. Figure 10 indicates typical equipment connected
lO a ground window. such as: telco proteclOrs, modems, telco
repeaters. FNE, e1C. The bar itself shall be directly con-
necled to Ihe intemal ground ring and 10 an immediately
adjacent ground rod.
7. TRANSMISSION LINES
1 GROUNDING LOCA nONS
The outer condUClOr of all coaxial transmission lines must be
grounded as follows:
1. Allhe lOp of Ihe vertical run on Ihe lOwer.
2. Atlhe bollOm of Ihe vertical run on Ihe lOwer.
3. Al Ihe point of enlraDCe 10 die radio equipment
building. This shall be immediately outside die
cable entrance. Transmission line grounds should .
be connected 10 Ihe nearest external ground bar by
an individual CondUClOr for each line. If Ihe cable
entrance halCh is metal. die tranSmission line grounds
may be connected 10 lhe haLCh. if desired.
7.2 GROUNDING KITS
Grounding of transmission lines is accomplished by use of
an appropriate grounding kit supplied by lhe transmission
line manufacturer. Examples of lhese kits are as follows: II
2" Ir.lnsmission line, Andrew 204989-1; 7/8" transmission
line, Andrew 40993A-S or 204989-2; I 5/8" transmission
line. Andrew 40993Ak-2 or 204989-4. The insuuctions
supplied wilh lhese kits are 10 be followed for application of
lhe grounding kiL (See product bulletins atlhe end of this
chapter.)
.
7.3 GROUNDING WITH MONOPOLE ANTENNA
TOWERS
On monopole antenna lOwers. grounding arrangements must
be specified when die monopole is purchased 10 provide lOp
and boaom grounding connections.
7.4 LIGHTNING SUPPRESSORS
Transmission line Iighming suppressors should be of gas
lube type wilh blocking capacitDrs, (ref. RRX-4000A series
product bulletin at the end of Iltis chapter) as opposed 10
conventional air gap suppressors (e.g., ST-786fT). Suppres-
sors must not be located on equipment cabinets. but rather
near the area coax entrance poinL Suppressors shaI1 be
grounded with short lengths of bonding suap. or #2 A WG
wire from multiple SlII'I"WSOt mounting bracketslpl8ICS 10
single point ground (Figun: 11).
8. GROUNDING PROVISIONS FOR
EXISTING Bun..DINGS
I
.
Existing buildings present a particularly diffICult grounding
situation. Usually the most difficult grounding problem is 10
find a ground. Every effon shall be made 10 determine what
grounding provisions already exist in the building. Particu-
larly imponant is fmding the building ground if it exists.
Other alternatives are metallic water pipes (if 1hey can be
verified as completely metal runs) and the building's StrUC-
tural steel.
,,-
0'
8.1 EQUIPMENT GROUNDING
IThe basic provisions of Section 6 must be follow~ . ~e
internal ground ring must be connected 10 the building s
grounding syStem.
8.2 ROOF.MOUNTEDANTENNAS
Tower and antennas mounted on the roof of an existing
building pose particular problems. Oearly. if lhe roof is
opened 10 provide reinforcemenl or direct connection 10 lhe
,
'.
.
4-6
MOTOROLA NA nONAL SERVICE
(Change 1)I/1l9l
4. GROUNDING AND BONDINr
steel suucture, the opponunity for a good ground is presenL
)
The antenna supponing suucwre must be grounded by a
minimum #2 A WG conductor to the building ground if
possible (Cadweld to the antenna mast or suppon where
practical). If multiple grounds or connection points arc
available, a ground ring around- the base of the lOwer or
group of antennas will provide a method of grounding anten-
nas and transmission lines.
All metal objects on the roof shall be appropriately bonded to
the roof grounding system:
8.3 PRE.AMPS
Any antenna-associated pre-amps must be connected to the
ground. Tower-mouDled pre-amps must be bonded to the
lower which also must be grounded.
8.4 TRANSMISSION LINE ENTRANCE TO
BUILDING
The provisions of Section 7 arc to be followed as nearly as
possible. Every effon must be made to provide a good
ground for each transmission line at its point of entry to the
building. (See Product Bulletins 3721lD and 37916 at the
end of this chapter.)
9. GROUND RESISTANCE
MEASUREMENT
A maximum resistance, between any point on the ground
system and canh ground, must be ten ohms or less (Cellular
Systems 5 ohms or less). An insuument designed specifi.
cally to measure the resistance of a point to cacl1 ground shall
be used, and the insuuctions provided with the instrument
shall be followed for proper measurement method (such as
Biddle Direct Reading Eanh Testcrmodcl #250260 orcquiva.
lent). All connections should be checked if this specification
cannot be meL Alternative grounding methods (e.g. Ufer or
chemical treatment) may be called for. Consult your engi-
neering department for specifIC recommendations.
10. LIGHTNING PROTECTION
MEASURES
In addition to the measures described under the preceding
sections, the following special considerations must be made
to minimize damage from lighming strikes and other unusual
electrical disturbances.
10.1 TRANSMISSION LINE
Any unused transmission line must have the center conduc-
tor shorted to the outer conductor or a lighming arreslOr
installed.
10.2 TELEPHONE LINES
Each telephone line (pair) entering or leaving a site must be
equipped with a thrcc-clcctrodc gas tube protector such as
the Cook Electric 9A, Porta System 581P-2, orequivalenL
Other types of protectors arc acceptable as long as they
provide line-to line and line-to-ground (thrcc-clcctrodc) pr0-
tection, and have operating characteristics equal to or better
than gas wbe protectors. Devices conraining gas wbe or
semiconductor (e.g., "Transorb") protection, such as the Porta
System device, arc preferred.
Since locallClephonc utilities operate indcpcndcDdy, nego-
tiations with utility rcprcscntativcs must include provision of
the typCofprotectors described. Normally, telephone com-
panies will provide carbon prolCClDrs which do not meet the
above requirements. If a ground window is used, the con-
nection will be made at the single point ground bar: but if a
ground window is not uscd. connections shall be made di-
rectly to the internal ring.
Telephone line proteCtors will be connected 10 the internal
ground ring as described in Para. 6.2.
10.3 AC POWER LINES
When installing a new site, it is recommended that AC
power be protected using a commercially-available master
AC surge protection device. such as a Joslyn Surgiuon TN.
This device must be capable of handling the site's maximum
rated load.
Another method of protecting AC power lincs is the use of
protectors. such as Motorola RRX4034B (dual voltage), on
each ungrounded service conductor. This protector may be
connected on the load side of the main disl:onncct or on a
branch circuit ovcrcurrcnt protection device (fuse or circuit
brcalcer) and must be sized large enough so it will not open
the circuit under normal Opcnltion of the AC proteCtor.
R56 (Change 1)
QUALITY STANDARDS. FNE Installations, Vol.l
4-7
4. ( 1UNDING AND BONDING
If insLallation as described above is not pt1ICtical, me AC
protector may be insLalled at me equipment itself, or me
lrola RRX-4019B prolCClOr may be used at me AC
U"l""lex connection.
The AC power line prolCClOrs shall be connected 10 me
Inlemal ground ring as in me stepS described in Para. 6.2.
II. ELECTROSTATIC DISCHARGE
(ESD) PROTECTION
An eleetrosratic discharge (ESD) occurs when two materials
come into contact, and men separate. Getting shocked when
reaching for a doorknob after walJdng across a carpet is an
example of ESD. Wbat would happen if you lOuched a
circuit board after walJdng across me same carpet? Chances
are, the ESD may be enough 10 destroy components like ICs
Jnd transislOrs-rendering the circuit board unusable. An-
other possibility is that ESD may only demKIe components
on the board. Components suffering this type of damage
of Len go undetected. In fact, a majority of service calls
resulting in "No Problem Found (NPF)" are caused by SlaUC-
damaged components. To prevent calaStrophes lilee "fried"
CMOS integrated circuits and erratically-operanng transIS-
lOrs, conductive wrist straps, sialic shielding bags and field
service ground kits must be used whenever handling ESD-
sensitive devices.
I "cse ESD-sensitive devices are handled more often than
you mightexpecL Once a device is shipped from me factory,
iL may be handled over and over again during its life. For
exam pie. the service center parts clerk, me lCChnician during
installation and maintenance, and the cuSlOmer if no they do
thc maintenance or installation. The key 10 malcing these de-
VICes last is by using the appropriate precautionary measures
every time they are handled. For example, how do you
properly unpack one of mese items? You must rust ground
yourself using a conductive wrist strap (42-8038SA59 ~
equivalent). Whether using a wrist strap from your 1001 ~t
or one that is at the site. If the wrist strap is used on a daily
basis, it is recommended that it be tested on daily using a
wrist strap tester (01-80320B62 or equivalent). Always place
Lhe strap around your wrist SO that it directly contacts the
skin. After ensuring that the cord is securely fastened 10 the
strap, attach me other end of me cord 10 a reliable ground
sue h as an unpainted portion of a grounded equipment rack.
It is recommended that each rack have a permanently mounted
wrist strap. You may now open the box and remove me s~c
shielding bag containing me circuit board or module. Smce
you are properly grounded, you may safely remove me mod-
ule from the bag.
What do you do with the module now that it is unpacked and
vulnerable 10 ESD damage? Since you are stiU grounded via
the conductive wrist strap, the circuit board or module may
be installed in a grounded equipment rack. But what if you
need 10 perform modifications or change jumper sellings on
a circuit board? A swic-dissipative mat shall be used as a
temporary work station. Place the mat in an area that is free
from nonconductors (e.g., plastic bags, document prolCClOrs,
polystyrene cups). Before placing a module on it, ground the
work slalion 10 an equipment rack. By keeping you and the
work station properly grounded and clear of nonconduclOrs,
modifications and jumper settings may be petformed wim-
out the threat of having me item damaged by ESD.
.
A test plan for ESD-protective devices is a must 10 ensure
that the above procedures are effective against ESD damage.
Wrist straps should be tested using a wrist strap tester on a
daily basis. Sratic-dissipative work mats should be lCSled
according 10 the manufacturer's recommendations. Trans-
parent metallized sratic-shielding bags should be tested us-
ing an ohmmeter. By measuring between the surface and me
folded area of the bag, the meter reading should be less than
100 kOhms. If it is greater than 100 kOhms. it should be
discarded. Other reasons for discarding a sratic shielding
bag are holes, punctures, tears, and/or ripped seams.
Troubleshooting also presents the opportunity for electro-
static discharges. JlefoR removing modules or circuit \lOlIrds
Ii'tlm an equiprnenl rack, ensure lhat YOOlR ~y grounded
via a conductive wrist strap. Yau may even want 10 set up a
field service ground kit (01-80371B21 or equivalent) so you
have an ESD-safe area where these items may be placed. If
you replace a module or circuit board, make sure that the de-
fective unit is prolCCted from further ESD-damage by plac-
ing it in a sialic shielding bag.
If you need 10 store, ship, or carry one of these ESD-sensitive
devices, place it in a properly-sized sialic shielding ~.
Sialic shielding bags are transparent bags impregnated WIth
metal particles. This type of bag prevents sialic build up on
the inside while keeping el"'llostatic discharges from ~-
ing from the outside. Wim the device safely lDCked ~y U\
one of these bags, you may then disconnect your wrISt Strap
in order 10 move about more freely. You may even place the
board or module on a rabie, if you desire, in order 10 continue
working with both hands.
.
".
~
I
.
4-8
MOTOROLA NA TlONAL SERVICE
(Change 1)1nJ9\
EXHmIT H
SOFfW ARE LICENSES
SOFTWARE LICENSE AGREEMENT
This Ucense Agreement is between MOTOROLA, INC., a Delaware
Corporation, by and through its Land Mobile Products Sector, having an
office at 1301 East Algonquin Road, Schaumburg, Illinois 60196
('Motorola') and the licensee named below ('Licensee').
BACKGROUND
Motorola has developed or acquired, or will develop or acquire
Programs (as hereinafter defined). The Licensee wishes, either now and/or
in the future, to obtain the right to use such Programs. Motorola is willing
to allow such use, provided the LIcensee agrees to observe certain terms
and conditions governing such use. The Licensee is willing to be so bound.
At the time of seeking to obtain rights to any particular Program,
Motorola may indicate to the Licensee that such a Program itself
constitutes, or is part of a Motorola Product that is designated by Motorola
as being a Category One (or, in the alternative, Level One), a Category Two
(or, in the alternative, a Level Two), a Category Three (or, in the
alternative, a Level Three), or a Category Four (or, in the alternative, a
Level Four) product or Program. It is also possible that no particular
Category or Level will be identified for a particular product or Program.
Pursuant to this Software License Agreement, the Licensee can
obtain a right to use Programs, with various rights and obligations being
set forth herein as specifically applicable to Programs of different
Categories.
NOW, THEREFORE, in consideration of the premises and the mutual
covenants hereinafter expressed, Licensee and Motorola agree as follows:
SECTION 1 - DEFINITIONS
1 .1 'Licensee' shall mean the licensee set forth at the end of this
Agreement.
1.2 'Licensee's Personnel' shall mean any person who is directly
employed by the Licensee.
1.3 'Motorola Products' shall mean bona fide Motorola products designed,
manufactured, acquired and/or sold by Motorola's Land Mobile Products
Sector, as identified in purchase contracts or as otherwise identified.
"Motorola Products' shall not include products that were originally
'Motorola Products,' but that have been modified in such a way that the
1
products no longer comply with Motorola's published specifications for
such products as of the time of manufacture of such products by Motorola.
1.4 "Embedded" shall mean object code that is resident in an unalterable
media, such as, for example, in a masked microprocessor, ROM, or PROM, or
in an alterable media that is not ordinarily altered during ordinary use of a
Motorola Product that includes the alterable media, such as, for example,
EPROM or EEPROM.
1.5 "Program," "Programs," and "Program(s)" shall all mean Motorola
object code that is provided by Motorola for use in conjunction with
Motorola Products or for use within Motorola Products, and shall include
later provided object code supplements and updates to any item of
Motorola object code.
1.6 "Site" refers to a specified geographic location where useage of
Programs is allowed. To the extent that Motorola shall, in a particular
instance, specifically identify a particular Motorola Product or other
platform as a "site" for a particular identified Program or Programs, then
that particular Motorola Product or other platform shall, for purposes of
this Agreement, be a "Site."
SECTION 2 - LICENSE AND CONDITIONS OF USE
2.1 Motorola hereby grants to Licensee a personal, nonexclusive license
under Motorola's applicable patents, copyrights, and trade secret rights to
use Program(s) under the following terms and provisions (these terms and
provisions shall be applicable to all Categories (unless provided otherwise
below), and shall also be applicable in each instance where no particular
Category has been identified for a particular Program or Motorola Product):
2.1.1 Licensee may only use the Program(s) at a Site, or Sites,
expressly stated in purchase contracts pertaining to the Programs, or at a
Site, or Sites that are otherwise identified in a writing that is provided to
Motorola at the time the Licensee originally requests to use the particular
Program or Programs. If a Site is not so specified, the Licensee may use
the Program(s) only at the business address where the Program(s) was
initially delivered by Motorola, or to such other business address where
the Program(s) was initially installed with Motorola's knowledge and
written acknowlegement, unless otherwise provided herein.
2.1.2 Licensee acknowledges Motorola's claim that the
Program(s) contain valuable proprietary information and trade secrets, and
that unauthorized dissemination. distribution, modification, reverse
2
engineering, disassembly, or unauthorized use of the Program(s) could
cause irreparable harm to Motorola, and thus Licensee agrees not to
reverse engineer, disassemble, disclose, transfer, provide, or otherwise
make available in any form whatsoever the Program(s), the information
therein, or any portion thereof, to any person or organization other than
Licensee's Personnel without the prior written consent of Motorola.
2.1.3 Licensee shall not modify, adapt, or merge any Program,
or alter the operability of any Program, except as specifically authorized
in writing by Motorola in advance of any such modification, adaptation,
merge, or alteration.
2.1.4 Since unauthorized use of such Program(s) can greatly
diminish the value of such trade secrets and cause irreparable harm to
Motorola, Licensee agrees that Motorola, in addition to any other remedies
it may have, shall be entitled to equitable relief to protect such trade
secrets, including without limitation, temporary and permanent injunctive
relief without the proving of damages by Motorola.
2.1.5 Licensee will take appropriate action, by instruction,
agreement or otherwise, with any persons, inciuding Licensee's Personnel,
permitted access to the Program(s), such that Licensee satisfies its
confidentiality obligations under this License Agreement.
2.1.6 The Licensee shall include all copyright notices,
trademark notices, and other proprietary legends in accordance with
Motorola's instructions on all copies of the Program(s).
2.1.7 Title to the Program(s) and any copies thereof, in whole
or in part, and all rights in patents, copyrights, trade secrets, and other
intellectual properties in such Program(s) are vested in, and shall remain
vested in, Motorola.
2.1.8 Licensee acknowledges and agrees that the existence of
any copyright notice on any Program shall not be construed as an
admission or presumption that publiC disclosure of trade secrets, or
'publication of sucl;l.Program, has occurred.
2.1.9 Licensee shall comply with the export regulations of the
Office of Export Administration for the United States Department of
Commerce with respect to the Programs.
3
2.1.10 Unless otherwise provided herein, the rights provided in
this License Agreement shall not be assigned or otherwise transferred by
the Licensee to a third party, and any such attempt shall be null and void.
2.1.11 Motorola reserves the right to assign this License
Agreement, encumber or sell any Program, or subcontract any of its
obligations hereunder, either in whole or in part, without notice to or the
consent of Licensee.
2.2 CATEGORY ONE SOFTWARE LICENSE: In addition to the rights and
conditions set forth in Section 2.1 above, Motorola hereby further grants
to Licensee a personal, nonexclusive Category One Software License for
any Program(s) provided to Licensee by Motorola that is identified, in a
writing, as being a category one (or level one) product. A Category One
Software License shall contain the following terms and provisions (in the
event of any conflict between the terms set forth in Section 2.1 and those
set forth in Section 2.2, the terms set forth in Section 2.2 shall prevail
with respect to the specific terms in conflict):
2.2.1 The Licensee may have up to four (4) archival copies of a
Category One Program in existence at anyone time, which archival copies
shall only be used to backup the original Program(s).
2.3 CATEGORY TWO SOFTWARE LICENSE: In addition to the rights and
conditions set forth in Section 2.1 above, Motorola hereby further grants
to Licensee a personal, nonexclusive Category Two Software License for
any Program(s) provided to Licensee by Motorola that is identified, in a
writing, as being a category two (or level two) product. A Category Two
Software License shall contain the following terms and provisions (in the
event of any conflict between the terms set forth in Section 2.1 and those
set forth in Section 2.3, the terms set forth in Section 2.3 shall prevail
with respect to the specific terms in conflict):
2.3.1 Licensee may transfer a Category Two Program(s) in its
entirety to a Transferee, but only if the Program(s) is transferred as
Embedded in a corresponding Motorola Product, and only if the Transferee
agrees in writing to use the Program(s) under license terms and provisions
that are at least as restrictive as those set forth herein, and Motorola is
provided with a copy of such writing.
2.3.2 Licensee may use a Category Two Program(s) in its
Embedded form in a corresponding Motorola Product without territorial
4
restriction, unless otherwise agreed to in writing by Motorola and the
Licensee.
2.3.3 Notwithstanding any other provision in this License
Agreement to the contrary, Licensee shall make no copies, archival or
otherwise, in whole or in part, of a Category Two Program(s), except
insofar as ordinary use of the Program(s) as prescribed by Motorola shall
create a copy thereof.
2.4 CATEGORY THREE SOFTWARE LICENSE: In addition to the rights and
conditions set forth in Section 2.1 above, Motorola hereby further grants
to Licensee a personal, nonexclusive Category Three Software License for
any Program(s) provided to Licensee by Motorola that is identified, in a
writing, as being a category three (or level three) product. A Category
Three Software License shall contain the following terms and provisions
(in the event of any conflict between the terms set forth in Section 2.1
and those set forth in Section 2.4, the terms set forth in Section 2.4 shall
prevail with respect to the specific terms in conflict):
2.4.1 The rights granted herein pursuant to Sections 2.1 and
this Section 2.4 for Category Three products shall be effective:
(A) after the Licensee has signed this Software License
Agreement and returned this Software License Agreement to
Motorola at an address specified by Motorola; and
(B) the earlier occurence of either:
(i) Motorola acknowledges to Licensee Motorola's acceptance
of this Software License Agreement in writing; or
(ii) Motorola ships to the Licensee an item of Category Three
software as ordered by the Licensee.
(C) THE BANKING, NEGOTIATION, OR OTHER USE OF ANY PAYMENT
MADE BY THE LICENSEE, IF ANY, SHALL NOT CONSTITUTE AN
ACCEPTANCE OF THIS SOFiiWARE LICENSE AGREEMENT BY
MOTOROlA
2.4.2 If the Licensee wishes to use a particular version of a
Category Three Program at more than one location, then the Licensee shall
obtain from Motorola at least one copy of the Program for each such
location. Provided such sufficient number of copies are so obtained, the
Licensee may make additional copies of such a Category Three Program(s)
5
to service a Site, or Sites, which Sites shall be expressly identified in
purchase contracts pertaining to the Programs or otherwise identified in a
written agreement at the time of sale that is signed by at least Motorola.
If a Site is not so specified, the Licensee then shall only make copies of
the corresponding Category Three Program(s) in sufficient quantities to
service the business address where the Program(s) was initially installed
with Motorola's knowledge. Within ten (10) business days of Motorola's
written request, the Licensee shall provide to Motorola a written
identification of all locations where the Licensee has the Program(s), or a
copy of the Program(s).
2.4.3 The Licensee shall not use any Category Three Programs,
or files that are accessed, created, or maintained by a Category Three
Program, to modify a Motorola Product, or cause a Motorola Product to be
modified, in any manner that:
(A) constitutes an illegal, unfair, or deceptive trade practice
under any applicable federal, state, or local law, rule, or
regulation; or
(B) constitues an infringement of any of Motorola's intellectual
property rights, including Motorola's patent rights, trademark
rights, copyrights, and/or trade secret rights.
2.4.4 All right to use a Category Three Program under this
Agreement may be terminated by either party without cause and for
convenience upon the giving of ten (10) days written notice by the
terminating party to the other party. Licensee's notice of termination shall
include a return to Motorola of all originals and copies of any Program(s),
including associated documentation, for which the Licensee seeks to
terminate the license. Upon termination by Motorola, the Licensee shall
return to Motorola all originals and copies of the corresponding Program(s)
and associated documentation.
2.4.5 In the event of any failure by the Licensee to observe the
terms and conditions set forth in either Sections 2.1 above or this Section
2.4 with respect to any Category Three Program, then in addition to any
other rights and remedies that are available to Motorola under law or
equity, Motorola may:
(A) withhold performance hereunder; or
(B) terminate the entire license under this Section 2.4; or
6
(C) demand and be entitled to the immediate return of all
copies of any and all items of Category Three Programs; or
(0) repossess, by any appropriate means, with or without
notice to the Licensee, all items of Category Three Programs.
Such remedies shall be cumulative and without any obligation upon
Motorola to exercise any particular remedy.
2.5 CATEGORY FOUR SOFTWARE LICENSE: In addition to the rights and
conditions set forth in Section 2.1 above, Motorola hereby further grants
to Licensee a personal, nonexclusive Category Four Software License for
any Program(s) provided to Licensee by Motorola that is identified, in a
writing, as being a category four (or level four) product. A Category Four
Software License shall contain the following terms and provisions (in the
event of any conflict between the terms set forth in Section 2.1 and those
set forth in Section 2.5, the terms set forth in Section 2.5 shall prevail
with respect to the specific terms in conflict):
2.5.1 Licensee shall not enable, disable, or otherwise add or
delete feature functionality with respect to a Motorola Product by
accessing, altering, or reconfiguring the operability of a corresponding
Category Four Program(s) except by a prior written agreement with
Motorola and with Motorola's prior knowledge of the specific feature
functionality to be enabled, disabled, or otherwise added or deleted.
2.5.2 Notwithstanding any other provision in this License
Agreement to the contrary, Licensee shall make no copies, archival or
otherwise, in whole or in part, of any Category Four Program(s), except
insofar as ordinary use of the Program(s) as prescribed by Motorola shall
create a copy thereof.
2.5.3 Licensee may transfer a Category Four Program(s) in its
entirety to a Transferee, but only if the Program(s) is transfe~red as
Embedded in a corresponding Motorola Product, and only if the Transferee
agrees in writing to use the Program(s) under license terms and provisions
that are at least as restrictive as those set forth herein, and Motorola is
provided with a copy of such writing.
2.5.4 Licensee may use a Category Four Program(s) in its
Embedded form in a corresponding Motorola Product without territorial
restriction, unless otherwise agreed to in writing by Motorola and the
Licensee.
7
SECTION 3 - MAINTENANCE DISCLAIMER
3.1 Motorola shall not be responsible for support or field selVice
of any Program under this Ucense Agreement. Any maintenance by
Motorola, if available, shall be by separate agreement on Motorola's then
current terms and conditions and at Motorola's then current prevailing
rates for such maintenance.
SECTION 4 - TERM OF UCENSE AGREEMENT
4.1 This Agreement shall be effective from the date of Motorola's
approval as set forth below (or, in the case of Category Three Programs, as
set forth in Section 2.4.1 above). The Licensee shall be able to acquire
rights, subject to this Agreement, to use a Program(s) subsequently
acquired from Motorola, provided that such Program(s) is acquired from
Motorola at a time during the three (3) year term following the effective
date of this Agreement.
4.2 The Licensee shall be perpetually entitled to use the Programs so
acquired pursuant to the terms of this License Agreement for so long as
the Licensee shall continue to use the corresponding Motorola Products.
Licensee's obligations under Section 2 shall continue past termination
except insofar as the exceptions of Section 5 are applicable.
4.3 The right to use Programs under this License Agreement may be
earlier terminated for the reasons set forth in Section 6 hereinbelow.
SECTION 5 - EXCEPTIONS
5.1 The Licensee's obligations with respect to confidentiality under
this Agreement shall not apply to those parts of a Program(s) that:
5.1.1 Is or becomes publicly known through no wrongful act on
the part of Licensee;
5.1.2 Is already known to Licensee at the time of disclosure;
5.1.3 Is rightfully received by Licensee from a third party
without breach of this License Agreement; or
5.1.4 Is explicitly approved for public release by written
authorization of Motorola.
8
5.2 That an exception under Section 5.1 may be applicable shall not
diminish in any way any other obligations the Licensee may have, such as
those obligations that are based upon patent and copyright interests of
Motorola.
SECTION 6 - TERMINATION FOR CAUSE
6.1 A party to this Agreement may give written notice of termination
to a breaching party if the breaching party commits a material breach of
any of its obligations: (1) as set forth herein; (2) as set forth in a purchase
contract for a Program(s); or (3) as set forth in any other agreement
between the parties regarding such Program(s). The written notice of
termination shall specify the material breach and must specify whether
the entire License Agreement is being terminated or whether the License
Agreement is being terminated with respect to a particular Program, or
particular Programs. Upon receipt of the written notice of termination,
the breaching party shall have ten (10) business days to cure the material
breach. In the event that the material beach is not cured during the ten
(10) working days, the License Agreement is terminated as specified in
the written notice of termination.
6.2 Upon termination of this License Agreement in its entirety or
termination of this License Agreement for any particular Program(s) by
Motorola for cause, Licensee shall promptly forward to Motorola, or to
Motorola's designee, all copies of Programs for which this License
Agreement is terminated. In the event a Program is Embedded in a Motorola
Product, the Licensee shall either return the Motorola Product (or that
portion of the Motorola Product that contains the Program), or verify
destruction of the Embedded Program.
SECTION 7 - WARRANTY
7.1 For the first one (1) year following its initial shipment, Motorola
warrants that, when properly used, its Programs will be free from
reproducible defects that cause a material variance from its published
specification. However, Motorola does not warrant that Program operation
will be uninterrupted or error-free, that each and every defect will be
corrected. or that any Program will meet Licensee's particular
requirements.
7.2 MOTOROLA'S TOTAL liABILITY AND liCENSEE'S SOLE REMEDY FOR
ANY WARRANTED PROGRAM SHALL BE liMITED TO, AT MOTOROLA'S OPTION,
PROGRAM REPLACEMENT OR THE PAYMENT OF liCENSEES ACTUAL DAMAGES,
NOT TO EXCEED THE SUMS PAID TO MOTOROLA FOR THE MOTOROLA PRODUCT
9
INCORPORATING THE DEFECTIVE PROGRAM. THIS WARRANTY EXTENDS ONLY
TO THE FIRST LICENSEE; SUBSEQUENT TRANSFEREES ACCEPT THESE
PROGRAMS "AS IS" AND WITHOUT WARRANTIES OF ANY KIND. THIS
WARRANTY REPLACES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE.
SECTION 8 - LIMITATION OF LIABILITY
8.1 The entire Motorola liability to Licensee for damages concerning
performance or nonperformance by Motorola under the License Agreement
or in any way related to the subject matter of the License Agreement,
regardless of whether the claim for such damages is based in contract,
tort or otherwise, and Licensee's sole and exclusive remedy shall be
limited to the payment by Motorola of actual damages not to exceed the
total License fee paid by Licensee for the Program, or Programs that
caused the damages or is the subject matter of or is directly related to
such claim.
8.2 IN NO EVENT SHALL MOTOROLA BE LIABLE FOR SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION
LOSS OF USE, TIME OR DATA, INCONVENIENCE, COMMERCIAL LOSS, LOST
PROFITS OR SAVINGS) TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY
LAW EVEN IF MOTOROLA HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES OR FOR ANY CLAIM AGAINST LICENSEE BY ANY OTHER PARTY.
SECTION 9 - PATENTS, COPYRIGHTS, & TRADE SECRETS
If promptly notified in writing, Motorola will defend any suit
against Licensee that claims that U.S. patents, copyrights, or trade secrets
of another have been infringed solely by Motoria's unaltered Programs and
will pay any associated costs or damages finally awarded. Upon Motorola's
request, Licensee agrees to reasonably assist in any defense and surrender
control of the suit to Motorola. Motorola may elect, at any time, to modify
or replace these Programs with equivalent non-infringing items, obtain
the right to continue using the Programs or, if these remedies are not
reasonably available, to terminate this License Agreement with respect to
such Programs. Motorola shall have no liability for infringement that
arises from any modification of Motorola's Programs by Licensee or from
Licensee's combination of Motorola's Programs with another's.
10
SECTION 10- U.S. GOVERNMENT LICENSE PROVISIONS
10.1 In the event that the Licensee is the U.S. Government or a U.S.
Government agency, then the provisions of this Section 10 shall also apply.
10.2 All Programs were developed at private expense. Programs and
associated documentation mayor may not include a Restricted Rights notice,
or other notice referring specifically to the terms and conditions of this
Agreement.
10.3 Use, duplication, or disclosure of Programs and associated
documentation under Motorola's copyrights and/or trade secret rights is
subject to the restrictions set forth in subparagraphs (c)(1) and (2) of the
Commercial Computer Software--Restricted Rights clause at FAR 52.227-19.
This FAR clause shall apply unless the Licensee is the Department of Defense,
in which case subparagraph (c)(1)(ii) of the Rights in Technical Data and
Computer Software clause at DFARS 252.227-7013 shall apply.
10.4 Provided that Motorola brings the terms and conditions of this
License Agreement, in writing, to the attention of the purchasing agent of the
procuring agency, the terms and conditions other than those set forth in
Section 10 of this License Agreement shall each continue to apply, but only to
the extent that such terms and conditions are not inconsistent with the
aforementioned provisions of the FAR or DFARS, as applicable to the
particular procuring agency and procurement transaction.
SECTION 11 - GENERAL PROVISIONS
11 .1 This License Agreement constitutes the complete and exclusive
statement of the agreement between Motorola and Licensee, and
supersedes all oral or written proposals, prior agreements and other prior
communications between the parties, concerning the subject matter of the
License Agreement.
11 .2 All formal notices, consents and other communications required
or permitted under this License Agreement shall be in writing and shall be
sent in such a way as to assure receipt by the other party. Either party
may change its address for formal notices by written notice to the other
party.
11 .3 This License Agreement shall be governed by and construed in
accordance with the laws of the United States of America to the extent to
which they apply, and, where they do not apply, in accordance with the
laws of the State of Illinois.
1 1
11.4 No representation or promise relating to, and no amendment of,
this License Agreement shall be binding unless it is in writing and signed
by both parties.
11 .5 The terms and conditions of this License Agreement shall prevail
notwithstanding any variance with the terms and conditions of any order
submitted by Licensee. Notwithstanding the foregoing, when this License
Agreement is specifically incorporated by direct reference as an exhibit
into another written agreement that has been signed by both parties hereto
and that includes terms that are directly inconsistent with terms included
in Section 7 of this Agreement regarding the commencement or duration of
warranty, or with terms included in Section 8.1 of this Agreement, then
the directly inconsistent terms in the other written agreement shall
prevail.
11.6 Motorola shall not be liable for any failure to perform due to
causes beyond its reasonable control.
11 .7 No waiver by a party of any breach of any provision of this License
Agreement shall constitute a waiver of any other breach of that or any
other provision of this License Agreement.
11 .8 Licensee recognizes that applicable Federal Communications Act
and other statutes, laws, ordinances, rules, and regulations may change
from time to time and that accordingly Motorola in its sole discretion has
the right without liability to modify this License Agreement to comply
with such change.
11.9 In the event that any of the provIsions contained in this License
Agreement are held to be unenforceable, this License Agreement shall be
construed without such provisions.
12
11.10 No action, regardless of form, arising out of the License
Agreement may be brought by Licensee more than one (1) year after the
cause of action has arisen.
ACCEPTED AND APPROVED AS OF
, 1993.
MOTOROLA:
UCENSEE:
MOTOROLA, INC.
City of San Bernardino, CA
BY:
BY:
(Authorized Signature)
(Authorized Signature)
Please type the following:
Please type the following:
NAME:
TITLE:
DATE:
NAME:
TITLE:
DATE:
Address for Formal Notices:
Address for Formal Notices:
Motorola, Inc.
1303 East Algonquin Road
Schaumburg, Illinois 60196
Attn: Intellectual Property Dept.
Attn:
13